Use of base metal casting alloys for implant framework: marginal accuracy analysis
Autor(a) principal: | |
---|---|
Data de Publicação: | 2004 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000400016 |
Resumo: | The original protocol for implant prosthesis recommends the use of a gold framework for acrylic and ceramic prosthesis. However, due to its high cost, the use of alternative alloys is desired. This study compares the marginal accuracy of pre-made cylinders versus plastic cylinders cast with two different base metal casting alloys. Five samples each of (1) plastic cylinder cast in cobalt-chromium alloy, (2) plastic cylinder cast in nickel-chromium alloy, and (3) silver-palladium pre-made cylinder (control) were examined for marginal accuracy according to: (A) vertical gap; (B) horizontal gap and (C) horizontal gap depth at the abutment/cylinder interface. Data were submitted to statistical analysis (ANOVA and Student-Newman Keuls, p<0.05). Mean values for vertical, horizontal and gap depth were 4.13µm, 14.5µm and 6.93µm for pre-made cylinder, 23.18µm, 33.2µm and 88µm for Ni-Cr cast cylinder and 25.6µm, 51.8µm and 114.54µm for Co-Cr cast cylinder. No statistically significant differences were found between cast groups (1 and 2), but significant better fit was obtained with pre-made metal cylinders when compared to cast cylinders with Ni-Cr and Co-Cr alloys, for all analyses. |
id |
USP-17_18b316f5098dacfae784cbfc53f73c63 |
---|---|
oai_identifier_str |
oai:scielo:S1678-77572004000400016 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
repository_id_str |
|
spelling |
Use of base metal casting alloys for implant framework: marginal accuracy analysisImplant prosthesisAlloys/misfitThe original protocol for implant prosthesis recommends the use of a gold framework for acrylic and ceramic prosthesis. However, due to its high cost, the use of alternative alloys is desired. This study compares the marginal accuracy of pre-made cylinders versus plastic cylinders cast with two different base metal casting alloys. Five samples each of (1) plastic cylinder cast in cobalt-chromium alloy, (2) plastic cylinder cast in nickel-chromium alloy, and (3) silver-palladium pre-made cylinder (control) were examined for marginal accuracy according to: (A) vertical gap; (B) horizontal gap and (C) horizontal gap depth at the abutment/cylinder interface. Data were submitted to statistical analysis (ANOVA and Student-Newman Keuls, p<0.05). Mean values for vertical, horizontal and gap depth were 4.13µm, 14.5µm and 6.93µm for pre-made cylinder, 23.18µm, 33.2µm and 88µm for Ni-Cr cast cylinder and 25.6µm, 51.8µm and 114.54µm for Co-Cr cast cylinder. No statistically significant differences were found between cast groups (1 and 2), but significant better fit was obtained with pre-made metal cylinders when compared to cast cylinders with Ni-Cr and Co-Cr alloys, for all analyses.Faculdade De Odontologia De Bauru - USP2004-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000400016Journal of Applied Oral Science v.12 n.4 2004reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/S1678-77572004000400016info:eu-repo/semantics/openAccessKano,Stefania CarvalhoBonfante,GersonHussne,RaquelSiqueira,Aline F.eng2005-01-10T00:00:00Zoai:scielo:S1678-77572004000400016Revistahttp://www.scielo.br/jaosPUBhttps://old.scielo.br/oai/scielo-oai.php||jaos@usp.br1678-77651678-7757opendoar:2005-01-10T00:00Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Use of base metal casting alloys for implant framework: marginal accuracy analysis |
title |
Use of base metal casting alloys for implant framework: marginal accuracy analysis |
spellingShingle |
Use of base metal casting alloys for implant framework: marginal accuracy analysis Kano,Stefania Carvalho Implant prosthesis Alloys/misfit |
title_short |
Use of base metal casting alloys for implant framework: marginal accuracy analysis |
title_full |
Use of base metal casting alloys for implant framework: marginal accuracy analysis |
title_fullStr |
Use of base metal casting alloys for implant framework: marginal accuracy analysis |
title_full_unstemmed |
Use of base metal casting alloys for implant framework: marginal accuracy analysis |
title_sort |
Use of base metal casting alloys for implant framework: marginal accuracy analysis |
author |
Kano,Stefania Carvalho |
author_facet |
Kano,Stefania Carvalho Bonfante,Gerson Hussne,Raquel Siqueira,Aline F. |
author_role |
author |
author2 |
Bonfante,Gerson Hussne,Raquel Siqueira,Aline F. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Kano,Stefania Carvalho Bonfante,Gerson Hussne,Raquel Siqueira,Aline F. |
dc.subject.por.fl_str_mv |
Implant prosthesis Alloys/misfit |
topic |
Implant prosthesis Alloys/misfit |
description |
The original protocol for implant prosthesis recommends the use of a gold framework for acrylic and ceramic prosthesis. However, due to its high cost, the use of alternative alloys is desired. This study compares the marginal accuracy of pre-made cylinders versus plastic cylinders cast with two different base metal casting alloys. Five samples each of (1) plastic cylinder cast in cobalt-chromium alloy, (2) plastic cylinder cast in nickel-chromium alloy, and (3) silver-palladium pre-made cylinder (control) were examined for marginal accuracy according to: (A) vertical gap; (B) horizontal gap and (C) horizontal gap depth at the abutment/cylinder interface. Data were submitted to statistical analysis (ANOVA and Student-Newman Keuls, p<0.05). Mean values for vertical, horizontal and gap depth were 4.13µm, 14.5µm and 6.93µm for pre-made cylinder, 23.18µm, 33.2µm and 88µm for Ni-Cr cast cylinder and 25.6µm, 51.8µm and 114.54µm for Co-Cr cast cylinder. No statistically significant differences were found between cast groups (1 and 2), but significant better fit was obtained with pre-made metal cylinders when compared to cast cylinders with Ni-Cr and Co-Cr alloys, for all analyses. |
publishDate |
2004 |
dc.date.none.fl_str_mv |
2004-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000400016 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000400016 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1678-77572004000400016 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science v.12 n.4 2004 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1748936433823907840 |