Influence of light curing source on microhardness of composite resins of different shades

Detalhes bibliográficos
Autor(a) principal: Briso,André Luiz Fraga
Data de Publicação: 2006
Outros Autores: Fedel,Tânia Maria, Pereira,Sibéria de Morais, Mauro,Sílvio José, Sundfeld,Renato Herman, Sundefeld,Maria Lúcia Marçal Mazza
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000100003
Resumo: INTRODUCTION: The evolution of light curing units can be noticed by the different systems recently introduced. The technology of LED units promises longer lifetime, without heating and with production of specific light for activation of camphorquinone. However, further studies are still required to check the real curing effectiveness of these units. PURPOSE: This study evaluated the microhardness of 4 shades (B-0.5, B-1, B-2 and B-3) of composite resin Filtek Z-250 (3M ESPE) after light curing with 4 light sources, being one halogen (Ultralux - Dabi Atlante) and three LED (Ultraled - Dabi Atlante, Ultrablue - DMC and Elipar Freelight - 3M ESPE). METHODS: 192 specimens were distributed into 16 groups, and materials were inserted in a single increment in cylindrical templates measuring 4mm x 4mm and light cured as recommended by the manufacturer. Then, they were submitted to microhardness test on the top and bottom aspects of the cylinders. RESULTS: The hardness values achieved were submitted to analysis of variance and to Tukey test at 5% confidence level. It was observed that microhardness of specimens varied according to the shade of the material and light sources employed. The LED appliance emitting greater light intensity provided the highest hardness values with shade B-0.5, allowing the best curing. On the other hand, appliances with low light intensity were the least effective. It was also observed that the bottom of specimens was more sensitive to changes in shade. CONCLUSION: Light intensity of LED light curing units is fundamental for their good functioning, especially when applied in resins with darker shades.
id USP-17_1a815353de7773a612d8d5c76b82ce67
oai_identifier_str oai:scielo:S1678-77572006000100003
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Influence of light curing source on microhardness of composite resins of different shadesMicrohardnessCuring equipmentComposite resinsShadesINTRODUCTION: The evolution of light curing units can be noticed by the different systems recently introduced. The technology of LED units promises longer lifetime, without heating and with production of specific light for activation of camphorquinone. However, further studies are still required to check the real curing effectiveness of these units. PURPOSE: This study evaluated the microhardness of 4 shades (B-0.5, B-1, B-2 and B-3) of composite resin Filtek Z-250 (3M ESPE) after light curing with 4 light sources, being one halogen (Ultralux - Dabi Atlante) and three LED (Ultraled - Dabi Atlante, Ultrablue - DMC and Elipar Freelight - 3M ESPE). METHODS: 192 specimens were distributed into 16 groups, and materials were inserted in a single increment in cylindrical templates measuring 4mm x 4mm and light cured as recommended by the manufacturer. Then, they were submitted to microhardness test on the top and bottom aspects of the cylinders. RESULTS: The hardness values achieved were submitted to analysis of variance and to Tukey test at 5% confidence level. It was observed that microhardness of specimens varied according to the shade of the material and light sources employed. The LED appliance emitting greater light intensity provided the highest hardness values with shade B-0.5, allowing the best curing. On the other hand, appliances with low light intensity were the least effective. It was also observed that the bottom of specimens was more sensitive to changes in shade. CONCLUSION: Light intensity of LED light curing units is fundamental for their good functioning, especially when applied in resins with darker shades.Faculdade De Odontologia De Bauru - USP2006-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000100003Journal of Applied Oral Science v.14 n.1 2006reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/S1678-77572006000100003info:eu-repo/semantics/openAccessBriso,André Luiz FragaFedel,Tânia MariaPereira,Sibéria de MoraisMauro,Sílvio JoséSundfeld,Renato HermanSundefeld,Maria Lúcia Marçal Mazzaeng2006-03-17T00:00:00Zoai:scielo:S1678-77572006000100003Revistahttp://www.scielo.br/jaosPUBhttps://old.scielo.br/oai/scielo-oai.php||jaos@usp.br1678-77651678-7757opendoar:2006-03-17T00:00Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Influence of light curing source on microhardness of composite resins of different shades
title Influence of light curing source on microhardness of composite resins of different shades
spellingShingle Influence of light curing source on microhardness of composite resins of different shades
Briso,André Luiz Fraga
Microhardness
Curing equipment
Composite resins
Shades
title_short Influence of light curing source on microhardness of composite resins of different shades
title_full Influence of light curing source on microhardness of composite resins of different shades
title_fullStr Influence of light curing source on microhardness of composite resins of different shades
title_full_unstemmed Influence of light curing source on microhardness of composite resins of different shades
title_sort Influence of light curing source on microhardness of composite resins of different shades
author Briso,André Luiz Fraga
author_facet Briso,André Luiz Fraga
Fedel,Tânia Maria
Pereira,Sibéria de Morais
Mauro,Sílvio José
Sundfeld,Renato Herman
Sundefeld,Maria Lúcia Marçal Mazza
author_role author
author2 Fedel,Tânia Maria
Pereira,Sibéria de Morais
Mauro,Sílvio José
Sundfeld,Renato Herman
Sundefeld,Maria Lúcia Marçal Mazza
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Briso,André Luiz Fraga
Fedel,Tânia Maria
Pereira,Sibéria de Morais
Mauro,Sílvio José
Sundfeld,Renato Herman
Sundefeld,Maria Lúcia Marçal Mazza
dc.subject.por.fl_str_mv Microhardness
Curing equipment
Composite resins
Shades
topic Microhardness
Curing equipment
Composite resins
Shades
description INTRODUCTION: The evolution of light curing units can be noticed by the different systems recently introduced. The technology of LED units promises longer lifetime, without heating and with production of specific light for activation of camphorquinone. However, further studies are still required to check the real curing effectiveness of these units. PURPOSE: This study evaluated the microhardness of 4 shades (B-0.5, B-1, B-2 and B-3) of composite resin Filtek Z-250 (3M ESPE) after light curing with 4 light sources, being one halogen (Ultralux - Dabi Atlante) and three LED (Ultraled - Dabi Atlante, Ultrablue - DMC and Elipar Freelight - 3M ESPE). METHODS: 192 specimens were distributed into 16 groups, and materials were inserted in a single increment in cylindrical templates measuring 4mm x 4mm and light cured as recommended by the manufacturer. Then, they were submitted to microhardness test on the top and bottom aspects of the cylinders. RESULTS: The hardness values achieved were submitted to analysis of variance and to Tukey test at 5% confidence level. It was observed that microhardness of specimens varied according to the shade of the material and light sources employed. The LED appliance emitting greater light intensity provided the highest hardness values with shade B-0.5, allowing the best curing. On the other hand, appliances with low light intensity were the least effective. It was also observed that the bottom of specimens was more sensitive to changes in shade. CONCLUSION: Light intensity of LED light curing units is fundamental for their good functioning, especially when applied in resins with darker shades.
publishDate 2006
dc.date.none.fl_str_mv 2006-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000100003
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572006000100003
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1678-77572006000100003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
dc.source.none.fl_str_mv Journal of Applied Oral Science v.14 n.1 2006
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1748936433967562752