Evaluation of the shear bond strength of the union between two CoCr-alloys and a dental ceramic

Detalhes bibliográficos
Autor(a) principal: Pretti, Mariana
Data de Publicação: 2004
Outros Autores: Hilgert, Edson, Bottino, Marco Antônio, Avelar, Rander Pereira
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/3221
Resumo: INTRODUCTION: Based on the importance of the integrity of the metal/ceramic interface, the purpose of this work was to evaluate the shear bond strength of the metal-ceramic union of two Co-Cr alloys (Wirobond C, Bego; Remanium 2000, Dentaurum) combined with Omega 900 ceramic (Vita Zahnfabrik). MATERIAL AND METHOD: Eleven cylindrical matrixes were made for each alloy, and the metallic portion was obtained with the lost wax casting technique with standardized waxing of 4mm of height and of 4mm of diameter. The ceramic was applied according to the manufacturer's recommendations with the aid of a teflon matrix that allowed its dimension to be standardized in the same size as the metallic portion. The specimens were submitted to the shear bond test in an universal testing machine (EMIC), with the aid of a device developed for such intention, and constant speed of 0.5mm/min. RESULTS AND CONCLUSIONS: The mean resistance was 48.387MPa for Wirobond C alloy, with standard deviation of 17.718, and 55.956MPa for Remanium 2000, with standard deviation of 17.198. No statistically significant difference was observed between the shear strength of the two metal-ceramic alloys.
id USP-17_3856ca686a3e7e89a7d970dedb6dc35a
oai_identifier_str oai:revistas.usp.br:article/3221
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Evaluation of the shear bond strength of the union between two CoCr-alloys and a dental ceramic Avaliação da resistência ao cisalhamento da união entre duas ligas a base de CoCr e uma cerâmica CerâmicasTeste de cisalhamentoLigasCeramicsShear testAlloys INTRODUCTION: Based on the importance of the integrity of the metal/ceramic interface, the purpose of this work was to evaluate the shear bond strength of the metal-ceramic union of two Co-Cr alloys (Wirobond C, Bego; Remanium 2000, Dentaurum) combined with Omega 900 ceramic (Vita Zahnfabrik). MATERIAL AND METHOD: Eleven cylindrical matrixes were made for each alloy, and the metallic portion was obtained with the lost wax casting technique with standardized waxing of 4mm of height and of 4mm of diameter. The ceramic was applied according to the manufacturer's recommendations with the aid of a teflon matrix that allowed its dimension to be standardized in the same size as the metallic portion. The specimens were submitted to the shear bond test in an universal testing machine (EMIC), with the aid of a device developed for such intention, and constant speed of 0.5mm/min. RESULTS AND CONCLUSIONS: The mean resistance was 48.387MPa for Wirobond C alloy, with standard deviation of 17.718, and 55.956MPa for Remanium 2000, with standard deviation of 17.198. No statistically significant difference was observed between the shear strength of the two metal-ceramic alloys. INTRODUÇÃO: Baseados na importância da integridade da interface metal-cerâmica, este trabalho tem como objetivo avaliar a resistência ao cisalhamento da união metal-cerâmica de duas ligas de Co-Cr (Wirobond C, Bego; Remanium 2000, Dentaurum) combinadas com a cerâmica Omega 900 (Vita Zahnfabrik). MATERIAIS E MÉTODOS: Foram confeccionados 11 corpos-de-prova cilíndricos para cada liga utilizada, sendo que a porção metálica foi obtida por fundição pela técnica da cera perdida, através de enceramentos padronizados com 4mm de altura por 4mm de diâmetro. A aplicação da cerâmica foi realizada segundo recomendações do fabricante, com auxílio de uma matriz de teflon que permitia sua padronização com as mesmas dimensões da porção metálica. Os corpos-de-prova foram submetidos ao ensaio de resistência ao cisalhamento em máquina de ensaios universal (EMIC), com auxílio de dispositivo desenvolvido para tal propósito, sob velocidade constante de 0,5mm/min. RESULTADOS E CONCLUSÕES: As médias de resistência obtidas foram 48,387 MPa para a liga Wirobond C, com desvio padrão de 17,718, e 55,956 MPa para a Remanium 2000, com desvio padrão de 17,198. Após análise de variância foi possível observar que não há diferença estatisticamente significante entre os valores de resistência ao cisalhamento das duas ligas metalocerâmicas. Universidade de São Paulo. Faculdade de Odontologia de Bauru2004-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/322110.1590/S1678-77572004000400005Journal of Applied Oral Science; Vol. 12 No. 4 (2004); 280-284 Journal of Applied Oral Science; Vol. 12 Núm. 4 (2004); 280-284 Journal of Applied Oral Science; v. 12 n. 4 (2004); 280-284 1678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/3221/3911Copyright (c) 2004 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessPretti, MarianaHilgert, EdsonBottino, Marco AntônioAvelar, Rander Pereira2012-04-27T11:48:35Zoai:revistas.usp.br:article/3221Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-04-27T11:48:35Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Evaluation of the shear bond strength of the union between two CoCr-alloys and a dental ceramic
Avaliação da resistência ao cisalhamento da união entre duas ligas a base de CoCr e uma cerâmica
title Evaluation of the shear bond strength of the union between two CoCr-alloys and a dental ceramic
spellingShingle Evaluation of the shear bond strength of the union between two CoCr-alloys and a dental ceramic
Pretti, Mariana
Cerâmicas
Teste de cisalhamento
Ligas
Ceramics
Shear test
Alloys
title_short Evaluation of the shear bond strength of the union between two CoCr-alloys and a dental ceramic
title_full Evaluation of the shear bond strength of the union between two CoCr-alloys and a dental ceramic
title_fullStr Evaluation of the shear bond strength of the union between two CoCr-alloys and a dental ceramic
title_full_unstemmed Evaluation of the shear bond strength of the union between two CoCr-alloys and a dental ceramic
title_sort Evaluation of the shear bond strength of the union between two CoCr-alloys and a dental ceramic
author Pretti, Mariana
author_facet Pretti, Mariana
Hilgert, Edson
Bottino, Marco Antônio
Avelar, Rander Pereira
author_role author
author2 Hilgert, Edson
Bottino, Marco Antônio
Avelar, Rander Pereira
author2_role author
author
author
dc.contributor.author.fl_str_mv Pretti, Mariana
Hilgert, Edson
Bottino, Marco Antônio
Avelar, Rander Pereira
dc.subject.por.fl_str_mv Cerâmicas
Teste de cisalhamento
Ligas
Ceramics
Shear test
Alloys
topic Cerâmicas
Teste de cisalhamento
Ligas
Ceramics
Shear test
Alloys
description INTRODUCTION: Based on the importance of the integrity of the metal/ceramic interface, the purpose of this work was to evaluate the shear bond strength of the metal-ceramic union of two Co-Cr alloys (Wirobond C, Bego; Remanium 2000, Dentaurum) combined with Omega 900 ceramic (Vita Zahnfabrik). MATERIAL AND METHOD: Eleven cylindrical matrixes were made for each alloy, and the metallic portion was obtained with the lost wax casting technique with standardized waxing of 4mm of height and of 4mm of diameter. The ceramic was applied according to the manufacturer's recommendations with the aid of a teflon matrix that allowed its dimension to be standardized in the same size as the metallic portion. The specimens were submitted to the shear bond test in an universal testing machine (EMIC), with the aid of a device developed for such intention, and constant speed of 0.5mm/min. RESULTS AND CONCLUSIONS: The mean resistance was 48.387MPa for Wirobond C alloy, with standard deviation of 17.718, and 55.956MPa for Remanium 2000, with standard deviation of 17.198. No statistically significant difference was observed between the shear strength of the two metal-ceramic alloys.
publishDate 2004
dc.date.none.fl_str_mv 2004-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3221
10.1590/S1678-77572004000400005
url https://www.revistas.usp.br/jaos/article/view/3221
identifier_str_mv 10.1590/S1678-77572004000400005
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3221/3911
dc.rights.driver.fl_str_mv Copyright (c) 2004 Journal of Applied Oral Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2004 Journal of Applied Oral Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 12 No. 4 (2004); 280-284
Journal of Applied Oral Science; Vol. 12 Núm. 4 (2004); 280-284
Journal of Applied Oral Science; v. 12 n. 4 (2004); 280-284
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1787713188791320576