Digital radiographic evaluation of optical density of porcelains used for fabrication of inlay/onlay prosthesis

Detalhes bibliográficos
Autor(a) principal: Castilho, Júlio Cezar de Melo
Data de Publicação: 2006
Outros Autores: Takeshita, Wilton Mitsunari, Santos, Luis Roque de Araújo dos, Moraes, Luiz César de, Medici Filho, Edmundo, Moraes, Mari Eli Leonelli de
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/3336
Resumo: The purpose of this article was to compare the mean value of optical density of four porcelains commonly used for fabrication of inlay/onlay prostheses using direct digital radiograph. The sample consisted of 20 2-mm thick porcelain specimens (measured by digital pachymeter): Empress (Ivoclair), Simbios (Degussa), Vita Omega 900 and Vitadur Alpha (Vita Zahnfabrik). The values of optical density of the specimens were expressed in millimeters aluminum equivalent (mm eq Al). The samples were X-rayed using two charge coupled devices (CCD) - RVG (Trophy) - Visualix (Gendex) and a phosphor plate system - Digora (Soredex). The optical density reading was performed with Image Tool 1.28 in a total of 110 measurements. Statistical analysis showed that there were statistically significant differences in all materials studied (p < 0.05) regardless of the radiographic system used. The highest optical density value was found for Omega 900 (1.8988 mmeqAl - Visualix - Gendex) and the lowest for Vitadur Alpha (0.8647 - Visualix - Gendex). Thus, the material presenting the highest degree of optical density was Omega 900, Empress and Simbios presented intermediate optical density values, Vitadur Alpha presented the lowest value, and the optical density of porcelains was not influenced by the digital radiography systems.
id USP-17_3d61c2bc78d612581eb78b477c9d8045
oai_identifier_str oai:revistas.usp.br:article/3336
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Digital radiographic evaluation of optical density of porcelains used for fabrication of inlay/onlay prosthesis Avaliação da densidade óptica de porcelanas usadas para confecção de próteses inlay/onlay por meio de radiografia digital Digital radiographyDental porcelainRadiografia digitalPorcelana dentária The purpose of this article was to compare the mean value of optical density of four porcelains commonly used for fabrication of inlay/onlay prostheses using direct digital radiograph. The sample consisted of 20 2-mm thick porcelain specimens (measured by digital pachymeter): Empress (Ivoclair), Simbios (Degussa), Vita Omega 900 and Vitadur Alpha (Vita Zahnfabrik). The values of optical density of the specimens were expressed in millimeters aluminum equivalent (mm eq Al). The samples were X-rayed using two charge coupled devices (CCD) - RVG (Trophy) - Visualix (Gendex) and a phosphor plate system - Digora (Soredex). The optical density reading was performed with Image Tool 1.28 in a total of 110 measurements. Statistical analysis showed that there were statistically significant differences in all materials studied (p < 0.05) regardless of the radiographic system used. The highest optical density value was found for Omega 900 (1.8988 mmeqAl - Visualix - Gendex) and the lowest for Vitadur Alpha (0.8647 - Visualix - Gendex). Thus, the material presenting the highest degree of optical density was Omega 900, Empress and Simbios presented intermediate optical density values, Vitadur Alpha presented the lowest value, and the optical density of porcelains was not influenced by the digital radiography systems. Objetivo desse trabalho é comparar valores médios de densidade óptica de quatro porcelanas comumente utilizadas para confecção de inlay/onlay por meio da densidade óptica usando radiografia digital. A amostra constou de 20 corpos de prova com espessura de 2mm (mensurados em paquímetro digital) das porcelanas: Empress (Ivoclair), Simbios (Degussa), Vita Omega 900 e Vitadur Alpha (Vita Zahnfabrik). Os valores de densidade óptica das amostras foram expressos em milímetros equivalente em alumínio (mm eq Al). Os espécimes foram radiografados, utilizando dois sistemas de dispositivo de carga acoplada (CCD) - RVG (Trophy) - Visualix (Gendex) e um sistema de placa de fósforo - Digora (Soredex). A leitura da densidade óptica foi realizada no programa Image Tool 1.28 totalizando 110 medições. As leituras de densidade ópticas foram feitas no programa Image Tool 1.28 totalizando 110 mensurações. A análise estatística demonstrou que houve diferença estatisticamente significante entre a densidade óptica das porcelanas estudadas independentemente do sistema de radiografia empregado (p < 0,05). A porcelana Omega 900 obteve 1,8988mmeqAl - Visualix - Gendex e Vitadur Alpha 0,8647mmeqAl - Visualix - Gendex. Conclui-se que a porcelana Omega 900 apresentou os maiores valores de densidade óptica, enquanto que Empress e Simbios obtiveram valores intermiediários, Vitadur Alpha apresentou os menores valores de densidade óptica e a densidade óptica das porcelanas não foram influenciadas pelo sistema de radiografia digital. Universidade de São Paulo. Faculdade de Odontologia de Bauru2006-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/333610.1590/S1678-77572006000100004Journal of Applied Oral Science; Vol. 14 No. 1 (2006); 16-20 Journal of Applied Oral Science; Vol. 14 Núm. 1 (2006); 16-20 Journal of Applied Oral Science; v. 14 n. 1 (2006); 16-20 1678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/3336/4026Copyright (c) 2006 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessCastilho, Júlio Cezar de MeloTakeshita, Wilton MitsunariSantos, Luis Roque de Araújo dosMoraes, Luiz César deMedici Filho, EdmundoMoraes, Mari Eli Leonelli de2012-04-27T11:52:46Zoai:revistas.usp.br:article/3336Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2012-04-27T11:52:46Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Digital radiographic evaluation of optical density of porcelains used for fabrication of inlay/onlay prosthesis
Avaliação da densidade óptica de porcelanas usadas para confecção de próteses inlay/onlay por meio de radiografia digital
title Digital radiographic evaluation of optical density of porcelains used for fabrication of inlay/onlay prosthesis
spellingShingle Digital radiographic evaluation of optical density of porcelains used for fabrication of inlay/onlay prosthesis
Castilho, Júlio Cezar de Melo
Digital radiography
Dental porcelain
Radiografia digital
Porcelana dentária
title_short Digital radiographic evaluation of optical density of porcelains used for fabrication of inlay/onlay prosthesis
title_full Digital radiographic evaluation of optical density of porcelains used for fabrication of inlay/onlay prosthesis
title_fullStr Digital radiographic evaluation of optical density of porcelains used for fabrication of inlay/onlay prosthesis
title_full_unstemmed Digital radiographic evaluation of optical density of porcelains used for fabrication of inlay/onlay prosthesis
title_sort Digital radiographic evaluation of optical density of porcelains used for fabrication of inlay/onlay prosthesis
author Castilho, Júlio Cezar de Melo
author_facet Castilho, Júlio Cezar de Melo
Takeshita, Wilton Mitsunari
Santos, Luis Roque de Araújo dos
Moraes, Luiz César de
Medici Filho, Edmundo
Moraes, Mari Eli Leonelli de
author_role author
author2 Takeshita, Wilton Mitsunari
Santos, Luis Roque de Araújo dos
Moraes, Luiz César de
Medici Filho, Edmundo
Moraes, Mari Eli Leonelli de
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Castilho, Júlio Cezar de Melo
Takeshita, Wilton Mitsunari
Santos, Luis Roque de Araújo dos
Moraes, Luiz César de
Medici Filho, Edmundo
Moraes, Mari Eli Leonelli de
dc.subject.por.fl_str_mv Digital radiography
Dental porcelain
Radiografia digital
Porcelana dentária
topic Digital radiography
Dental porcelain
Radiografia digital
Porcelana dentária
description The purpose of this article was to compare the mean value of optical density of four porcelains commonly used for fabrication of inlay/onlay prostheses using direct digital radiograph. The sample consisted of 20 2-mm thick porcelain specimens (measured by digital pachymeter): Empress (Ivoclair), Simbios (Degussa), Vita Omega 900 and Vitadur Alpha (Vita Zahnfabrik). The values of optical density of the specimens were expressed in millimeters aluminum equivalent (mm eq Al). The samples were X-rayed using two charge coupled devices (CCD) - RVG (Trophy) - Visualix (Gendex) and a phosphor plate system - Digora (Soredex). The optical density reading was performed with Image Tool 1.28 in a total of 110 measurements. Statistical analysis showed that there were statistically significant differences in all materials studied (p < 0.05) regardless of the radiographic system used. The highest optical density value was found for Omega 900 (1.8988 mmeqAl - Visualix - Gendex) and the lowest for Vitadur Alpha (0.8647 - Visualix - Gendex). Thus, the material presenting the highest degree of optical density was Omega 900, Empress and Simbios presented intermediate optical density values, Vitadur Alpha presented the lowest value, and the optical density of porcelains was not influenced by the digital radiography systems.
publishDate 2006
dc.date.none.fl_str_mv 2006-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3336
10.1590/S1678-77572006000100004
url https://www.revistas.usp.br/jaos/article/view/3336
identifier_str_mv 10.1590/S1678-77572006000100004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/3336/4026
dc.rights.driver.fl_str_mv Copyright (c) 2006 Journal of Applied Oral Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2006 Journal of Applied Oral Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 14 No. 1 (2006); 16-20
Journal of Applied Oral Science; Vol. 14 Núm. 1 (2006); 16-20
Journal of Applied Oral Science; v. 14 n. 1 (2006); 16-20
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221672670756864