Association of Nd:YAG laser and calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion

Detalhes bibliográficos
Autor(a) principal: Maximiano, Vinícius
Data de Publicação: 2021
Outros Autores: Machado, Alana Cristina, Lopes, Raquel Marianna, Rabelo, Fernanda Ellen Mercatelli, Garófalo, Stephanie Assimakopoulos, Zezell, Denise Maria, Aranha, Ana Cecilia Corrêa, Scaramucci, Taís
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/187215
Resumo: Objective: To evaluate the efficacy of Nd:YAG laser associated with calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion after erosive/abrasive challenges. Methodology: Dentin specimens were exposed to 17% ethylene diamine tetra-acetic acid (EDTA) solution for 5 min and randomly allocated into five groups: G1, control (no treatment); G2, Nd:YAG laser (1 W, 10 Hz, 100 mJ, 85 J/cm2); G3, Laser + TeethmateTM Desensitizer; G4, Laser + Desensibilize Nano P; and G5, Laser+Nupro®. Specimens underwent a 5-day erosion-abrasion cycling. Hydraulic conductance was measured post-EDTA, post-treatment, and post-cycling. Post-treatment and post-cycling permeability (%Lp) was calculated based on post-EDTA measurements, considered 100%. Open dentin tubules (ODT) were calculated at the abovementioned experimental moments using scanning electron microscopy and ImageJ software (n=10). Data were analyzed using two-way repeated measures ANOVA and Tukey’s test (α=0.05). Results: G1 presented the highest %Lp post-treatment of all groups (p<0.05), without significantly differences among them. At post-cycling, %Lp significantly decreased in G1, showed no significant differences from post-treatment in G3 and G4, and increased in G2 and G5, without significant differences from G1 (p>0.05). We found no significant differences in ODT among groups (p>0.05) post-EDTA. At post-treatment, treated groups did not differ from each other, but presented lower ODT than G1 (p<0.001). As for post-cycling, we verified no differences among groups (p>0.05), although ODT was significantly lower for all groups when compared to post-EDTA values (p<0.001). Conclusion: All treatments effectively reduced dentin permeability and promoted tubule occlusion after application.
id USP-17_f7a0d0627fd99e8aca360fa5345be1af
oai_identifier_str oai:revistas.usp.br:article/187215
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Association of Nd:YAG laser and calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusionDentin hypersensitivityLaserDesensitizing agentsObjective: To evaluate the efficacy of Nd:YAG laser associated with calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion after erosive/abrasive challenges. Methodology: Dentin specimens were exposed to 17% ethylene diamine tetra-acetic acid (EDTA) solution for 5 min and randomly allocated into five groups: G1, control (no treatment); G2, Nd:YAG laser (1 W, 10 Hz, 100 mJ, 85 J/cm2); G3, Laser + TeethmateTM Desensitizer; G4, Laser + Desensibilize Nano P; and G5, Laser+Nupro®. Specimens underwent a 5-day erosion-abrasion cycling. Hydraulic conductance was measured post-EDTA, post-treatment, and post-cycling. Post-treatment and post-cycling permeability (%Lp) was calculated based on post-EDTA measurements, considered 100%. Open dentin tubules (ODT) were calculated at the abovementioned experimental moments using scanning electron microscopy and ImageJ software (n=10). Data were analyzed using two-way repeated measures ANOVA and Tukey’s test (α=0.05). Results: G1 presented the highest %Lp post-treatment of all groups (p<0.05), without significantly differences among them. At post-cycling, %Lp significantly decreased in G1, showed no significant differences from post-treatment in G3 and G4, and increased in G2 and G5, without significant differences from G1 (p>0.05). We found no significant differences in ODT among groups (p>0.05) post-EDTA. At post-treatment, treated groups did not differ from each other, but presented lower ODT than G1 (p<0.001). As for post-cycling, we verified no differences among groups (p>0.05), although ODT was significantly lower for all groups when compared to post-EDTA values (p<0.001). Conclusion: All treatments effectively reduced dentin permeability and promoted tubule occlusion after application.Universidade de São Paulo. Faculdade de Odontologia de Bauru2021-06-14info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/18721510.1590/1678-7757-2020-0736Journal of Applied Oral Science; Vol. 29 (2021); e20200736Journal of Applied Oral Science; Vol. 29 (2021); e20200736Journal of Applied Oral Science; v. 29 (2021); e202007361678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/187215/173027Copyright (c) 2021 Journal of Applied Oral Sciencehttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessMaximiano, Vinícius Machado, Alana Cristina Lopes, Raquel Marianna Rabelo, Fernanda Ellen Mercatelli Garófalo, Stephanie Assimakopoulos Zezell, Denise Maria Aranha, Ana Cecilia Corrêa Scaramucci, Taís2021-06-14T21:52:18Zoai:revistas.usp.br:article/187215Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2021-06-14T21:52:18Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Association of Nd:YAG laser and calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion
title Association of Nd:YAG laser and calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion
spellingShingle Association of Nd:YAG laser and calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion
Maximiano, Vinícius
Dentin hypersensitivity
Laser
Desensitizing agents
title_short Association of Nd:YAG laser and calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion
title_full Association of Nd:YAG laser and calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion
title_fullStr Association of Nd:YAG laser and calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion
title_full_unstemmed Association of Nd:YAG laser and calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion
title_sort Association of Nd:YAG laser and calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion
author Maximiano, Vinícius
author_facet Maximiano, Vinícius
Machado, Alana Cristina
Lopes, Raquel Marianna
Rabelo, Fernanda Ellen Mercatelli
Garófalo, Stephanie Assimakopoulos
Zezell, Denise Maria
Aranha, Ana Cecilia Corrêa
Scaramucci, Taís
author_role author
author2 Machado, Alana Cristina
Lopes, Raquel Marianna
Rabelo, Fernanda Ellen Mercatelli
Garófalo, Stephanie Assimakopoulos
Zezell, Denise Maria
Aranha, Ana Cecilia Corrêa
Scaramucci, Taís
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Maximiano, Vinícius
Machado, Alana Cristina
Lopes, Raquel Marianna
Rabelo, Fernanda Ellen Mercatelli
Garófalo, Stephanie Assimakopoulos
Zezell, Denise Maria
Aranha, Ana Cecilia Corrêa
Scaramucci, Taís
dc.subject.por.fl_str_mv Dentin hypersensitivity
Laser
Desensitizing agents
topic Dentin hypersensitivity
Laser
Desensitizing agents
description Objective: To evaluate the efficacy of Nd:YAG laser associated with calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion after erosive/abrasive challenges. Methodology: Dentin specimens were exposed to 17% ethylene diamine tetra-acetic acid (EDTA) solution for 5 min and randomly allocated into five groups: G1, control (no treatment); G2, Nd:YAG laser (1 W, 10 Hz, 100 mJ, 85 J/cm2); G3, Laser + TeethmateTM Desensitizer; G4, Laser + Desensibilize Nano P; and G5, Laser+Nupro®. Specimens underwent a 5-day erosion-abrasion cycling. Hydraulic conductance was measured post-EDTA, post-treatment, and post-cycling. Post-treatment and post-cycling permeability (%Lp) was calculated based on post-EDTA measurements, considered 100%. Open dentin tubules (ODT) were calculated at the abovementioned experimental moments using scanning electron microscopy and ImageJ software (n=10). Data were analyzed using two-way repeated measures ANOVA and Tukey’s test (α=0.05). Results: G1 presented the highest %Lp post-treatment of all groups (p<0.05), without significantly differences among them. At post-cycling, %Lp significantly decreased in G1, showed no significant differences from post-treatment in G3 and G4, and increased in G2 and G5, without significant differences from G1 (p>0.05). We found no significant differences in ODT among groups (p>0.05) post-EDTA. At post-treatment, treated groups did not differ from each other, but presented lower ODT than G1 (p<0.001). As for post-cycling, we verified no differences among groups (p>0.05), although ODT was significantly lower for all groups when compared to post-EDTA values (p<0.001). Conclusion: All treatments effectively reduced dentin permeability and promoted tubule occlusion after application.
publishDate 2021
dc.date.none.fl_str_mv 2021-06-14
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/187215
10.1590/1678-7757-2020-0736
url https://www.revistas.usp.br/jaos/article/view/187215
identifier_str_mv 10.1590/1678-7757-2020-0736
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/187215/173027
dc.rights.driver.fl_str_mv Copyright (c) 2021 Journal of Applied Oral Science
http://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2021 Journal of Applied Oral Science
http://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 29 (2021); e20200736
Journal of Applied Oral Science; Vol. 29 (2021); e20200736
Journal of Applied Oral Science; v. 29 (2021); e20200736
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1787713196265570304