Comparative study of two commercially pure titanium casting methods

Detalhes bibliográficos
Autor(a) principal: Rodrigues,Renata Cristina Silveira
Data de Publicação: 2010
Outros Autores: Faria,Adriana Claudia Lapria, Orsi,Iara Augusta, Mattos,Maria da Gloria Chiarello de, Macedo,Ana Paula, Ribeiro,Ricardo Faria
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572010000500010
Resumo: The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. OBJECTIVE: This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clasps cast by induction/centrifugation and plasma/vacuum-pressure. MATERIAL AND METHODS: 72 frameworks were cast from CP Ti (n=36) and Co-Cr alloy (n=36; control group). For each material, 18 frameworks were casted by electromagnetic induction and injected by centrifugation, whereas the other 18 were casted by plasma and injected by vacuum-pressure. For each casting method, three subgroups (n=6) were formed: 0.25 mm, 0.50 mm, and 0.75 mm undercuts. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. Data were analyzed by ANOVA and Tukey's to compare materials and cast methods (α=0.05). RESULTS: Three of 18 specimens of the induction/centrifugation group and 9 of 18 specimens of plasma/vacuum-pressure cast presented porosities, but only 1 and 7 specimens, respectively, were rejected for simulation test. For Co-Cr alloy, no defects were found. Comparing the casting methods, statistically significant differences (p<0.05) were observed only for the Co-Cr alloy with 0.25 mm and 0.50 mm undercuts. Significant differences were found for the 0.25 mm and 0.75 mm undercuts dependent on the material used. For the 0.50 mm undercut, significant differences were found when the materials were induction casted. CONCLUSION: Although both casting methods produced satisfactory CP Ti RPD frameworks, the occurrence of porosities was greater in the plasma/vacuum-pressure than in the induction/centrifugation method, the latter resulting in higher clasp rigidity, generating higher retention force values.
id USP-17_fd78b03f96d0abba79f628d4680782b2
oai_identifier_str oai:scielo:S1678-77572010000500010
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Comparative study of two commercially pure titanium casting methodsChromium alloysDental casting techniqueMaterials testingRemovable partial denturesTitaniumThe interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. OBJECTIVE: This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clasps cast by induction/centrifugation and plasma/vacuum-pressure. MATERIAL AND METHODS: 72 frameworks were cast from CP Ti (n=36) and Co-Cr alloy (n=36; control group). For each material, 18 frameworks were casted by electromagnetic induction and injected by centrifugation, whereas the other 18 were casted by plasma and injected by vacuum-pressure. For each casting method, three subgroups (n=6) were formed: 0.25 mm, 0.50 mm, and 0.75 mm undercuts. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. Data were analyzed by ANOVA and Tukey's to compare materials and cast methods (α=0.05). RESULTS: Three of 18 specimens of the induction/centrifugation group and 9 of 18 specimens of plasma/vacuum-pressure cast presented porosities, but only 1 and 7 specimens, respectively, were rejected for simulation test. For Co-Cr alloy, no defects were found. Comparing the casting methods, statistically significant differences (p<0.05) were observed only for the Co-Cr alloy with 0.25 mm and 0.50 mm undercuts. Significant differences were found for the 0.25 mm and 0.75 mm undercuts dependent on the material used. For the 0.50 mm undercut, significant differences were found when the materials were induction casted. CONCLUSION: Although both casting methods produced satisfactory CP Ti RPD frameworks, the occurrence of porosities was greater in the plasma/vacuum-pressure than in the induction/centrifugation method, the latter resulting in higher clasp rigidity, generating higher retention force values.Faculdade De Odontologia De Bauru - USP2010-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572010000500010Journal of Applied Oral Science v.18 n.5 2010reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/S1678-77572010000500010info:eu-repo/semantics/openAccessRodrigues,Renata Cristina SilveiraFaria,Adriana Claudia LapriaOrsi,Iara AugustaMattos,Maria da Gloria Chiarello deMacedo,Ana PaulaRibeiro,Ricardo Fariaeng2010-11-05T00:00:00Zoai:scielo:S1678-77572010000500010Revistahttp://www.scielo.br/jaosPUBhttps://old.scielo.br/oai/scielo-oai.php||jaos@usp.br1678-77651678-7757opendoar:2010-11-05T00:00Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Comparative study of two commercially pure titanium casting methods
title Comparative study of two commercially pure titanium casting methods
spellingShingle Comparative study of two commercially pure titanium casting methods
Rodrigues,Renata Cristina Silveira
Chromium alloys
Dental casting technique
Materials testing
Removable partial dentures
Titanium
title_short Comparative study of two commercially pure titanium casting methods
title_full Comparative study of two commercially pure titanium casting methods
title_fullStr Comparative study of two commercially pure titanium casting methods
title_full_unstemmed Comparative study of two commercially pure titanium casting methods
title_sort Comparative study of two commercially pure titanium casting methods
author Rodrigues,Renata Cristina Silveira
author_facet Rodrigues,Renata Cristina Silveira
Faria,Adriana Claudia Lapria
Orsi,Iara Augusta
Mattos,Maria da Gloria Chiarello de
Macedo,Ana Paula
Ribeiro,Ricardo Faria
author_role author
author2 Faria,Adriana Claudia Lapria
Orsi,Iara Augusta
Mattos,Maria da Gloria Chiarello de
Macedo,Ana Paula
Ribeiro,Ricardo Faria
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Rodrigues,Renata Cristina Silveira
Faria,Adriana Claudia Lapria
Orsi,Iara Augusta
Mattos,Maria da Gloria Chiarello de
Macedo,Ana Paula
Ribeiro,Ricardo Faria
dc.subject.por.fl_str_mv Chromium alloys
Dental casting technique
Materials testing
Removable partial dentures
Titanium
topic Chromium alloys
Dental casting technique
Materials testing
Removable partial dentures
Titanium
description The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. OBJECTIVE: This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clasps cast by induction/centrifugation and plasma/vacuum-pressure. MATERIAL AND METHODS: 72 frameworks were cast from CP Ti (n=36) and Co-Cr alloy (n=36; control group). For each material, 18 frameworks were casted by electromagnetic induction and injected by centrifugation, whereas the other 18 were casted by plasma and injected by vacuum-pressure. For each casting method, three subgroups (n=6) were formed: 0.25 mm, 0.50 mm, and 0.75 mm undercuts. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. Data were analyzed by ANOVA and Tukey's to compare materials and cast methods (α=0.05). RESULTS: Three of 18 specimens of the induction/centrifugation group and 9 of 18 specimens of plasma/vacuum-pressure cast presented porosities, but only 1 and 7 specimens, respectively, were rejected for simulation test. For Co-Cr alloy, no defects were found. Comparing the casting methods, statistically significant differences (p<0.05) were observed only for the Co-Cr alloy with 0.25 mm and 0.50 mm undercuts. Significant differences were found for the 0.25 mm and 0.75 mm undercuts dependent on the material used. For the 0.50 mm undercut, significant differences were found when the materials were induction casted. CONCLUSION: Although both casting methods produced satisfactory CP Ti RPD frameworks, the occurrence of porosities was greater in the plasma/vacuum-pressure than in the induction/centrifugation method, the latter resulting in higher clasp rigidity, generating higher retention force values.
publishDate 2010
dc.date.none.fl_str_mv 2010-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572010000500010
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572010000500010
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1678-77572010000500010
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
publisher.none.fl_str_mv Faculdade De Odontologia De Bauru - USP
dc.source.none.fl_str_mv Journal of Applied Oral Science v.18 n.5 2010
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1748936436143357952