The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study

Detalhes bibliográficos
Autor(a) principal: Li, Xue-Shi
Data de Publicação: 2014
Outros Autores: Wu, Zeng-Hui, Xia, Hong, Ma, Xiang-Yang, Ai, Fu-Zhi, Zhang, Kai, Wang, Jian-Hua, Mai, Xiao-Hong, Yin, Qing-Shui
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Clinics
Texto Completo: https://www.revistas.usp.br/clinics/article/view/96915
Resumo: OBJECTIVES: The transoral atlantoaxial reduction plate system treats irreducible atlantoaxial dislocation from transoral atlantoaxial reduction plate-I to transoral atlantoaxial reduction plate-III. However, this system has demonstrated problems associated with screw loosening, atlantoaxial fixation and concealed or manifest neurovascular injuries. This study sought to design a set of individualized templates to improve the accuracy of anterior C2 screw placement in the transoral atlantoaxial reduction plate-IV procedure. METHODS: A set of individualized templates was designed according to thin-slice computed tomography data obtained from 10 human cadavers. The templates contained cubic modules and drill guides to facilitate transoral atlantoaxial reduction plate positioning and anterior C2 screw placement. We performed 2 stages of cadaveric experiments with 2 cadavers in stage one and 8 in stage two. Finally, guided C2 screw placement was evaluated by reading postoperative computed tomography images and comparing the planned and inserted screw trajectories. RESULTS: There were two cortical breaching screws in stage one and three in stage two, but only the cortical breaching screws in stage one were ranked critical. In stage two, the planned entry points and the transverse angles of the anterior C2 screws could be simulated, whereas the declination angles could not be simulated due to intraoperative blockage of the drill bit and screwdriver by the upper teeth. CONCLUSIONS: It was feasible to use individualized templates to guide transoral C2 screw placement. Thus, these drill templates combined with transoral atlantoaxial reduction plate-IV, may improve the accuracy of transoral C2 screw placement and reduce related neurovascular complications.
id USP-19_19429dac286e55119f8e345d96bc077c
oai_identifier_str oai:revistas.usp.br:article/96915
network_acronym_str USP-19
network_name_str Clinics
repository_id_str
spelling The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study OBJECTIVES: The transoral atlantoaxial reduction plate system treats irreducible atlantoaxial dislocation from transoral atlantoaxial reduction plate-I to transoral atlantoaxial reduction plate-III. However, this system has demonstrated problems associated with screw loosening, atlantoaxial fixation and concealed or manifest neurovascular injuries. This study sought to design a set of individualized templates to improve the accuracy of anterior C2 screw placement in the transoral atlantoaxial reduction plate-IV procedure. METHODS: A set of individualized templates was designed according to thin-slice computed tomography data obtained from 10 human cadavers. The templates contained cubic modules and drill guides to facilitate transoral atlantoaxial reduction plate positioning and anterior C2 screw placement. We performed 2 stages of cadaveric experiments with 2 cadavers in stage one and 8 in stage two. Finally, guided C2 screw placement was evaluated by reading postoperative computed tomography images and comparing the planned and inserted screw trajectories. RESULTS: There were two cortical breaching screws in stage one and three in stage two, but only the cortical breaching screws in stage one were ranked critical. In stage two, the planned entry points and the transverse angles of the anterior C2 screws could be simulated, whereas the declination angles could not be simulated due to intraoperative blockage of the drill bit and screwdriver by the upper teeth. CONCLUSIONS: It was feasible to use individualized templates to guide transoral C2 screw placement. Thus, these drill templates combined with transoral atlantoaxial reduction plate-IV, may improve the accuracy of transoral C2 screw placement and reduce related neurovascular complications. Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo2014-11-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/clinics/article/view/9691510.6061/clinics/2014(11)08Clinics; v. 69 n. 11 (2014); 750-757Clinics; Vol. 69 Núm. 11 (2014); 750-757Clinics; Vol. 69 No. 11 (2014); 750-7571980-53221807-5932reponame:Clinicsinstname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/clinics/article/view/96915/95995Copyright (c) 2015 Clinicsinfo:eu-repo/semantics/openAccessLi, Xue-Shi Wu, Zeng-Hui Xia, Hong Ma, Xiang-Yang Ai, Fu-Zhi Zhang, Kai Wang, Jian-Hua Mai, Xiao-Hong Yin, Qing-Shui 2015-03-27T18:21:03Zoai:revistas.usp.br:article/96915Revistahttps://www.revistas.usp.br/clinicsPUBhttps://www.revistas.usp.br/clinics/oai||clinics@hc.fm.usp.br1980-53221807-5932opendoar:2015-03-27T18:21:03Clinics - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study
title The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study
spellingShingle The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study
Li, Xue-Shi
title_short The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study
title_full The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study
title_fullStr The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study
title_full_unstemmed The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study
title_sort The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study
author Li, Xue-Shi
author_facet Li, Xue-Shi
Wu, Zeng-Hui
Xia, Hong
Ma, Xiang-Yang
Ai, Fu-Zhi
Zhang, Kai
Wang, Jian-Hua
Mai, Xiao-Hong
Yin, Qing-Shui
author_role author
author2 Wu, Zeng-Hui
Xia, Hong
Ma, Xiang-Yang
Ai, Fu-Zhi
Zhang, Kai
Wang, Jian-Hua
Mai, Xiao-Hong
Yin, Qing-Shui
author2_role author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Li, Xue-Shi
Wu, Zeng-Hui
Xia, Hong
Ma, Xiang-Yang
Ai, Fu-Zhi
Zhang, Kai
Wang, Jian-Hua
Mai, Xiao-Hong
Yin, Qing-Shui
description OBJECTIVES: The transoral atlantoaxial reduction plate system treats irreducible atlantoaxial dislocation from transoral atlantoaxial reduction plate-I to transoral atlantoaxial reduction plate-III. However, this system has demonstrated problems associated with screw loosening, atlantoaxial fixation and concealed or manifest neurovascular injuries. This study sought to design a set of individualized templates to improve the accuracy of anterior C2 screw placement in the transoral atlantoaxial reduction plate-IV procedure. METHODS: A set of individualized templates was designed according to thin-slice computed tomography data obtained from 10 human cadavers. The templates contained cubic modules and drill guides to facilitate transoral atlantoaxial reduction plate positioning and anterior C2 screw placement. We performed 2 stages of cadaveric experiments with 2 cadavers in stage one and 8 in stage two. Finally, guided C2 screw placement was evaluated by reading postoperative computed tomography images and comparing the planned and inserted screw trajectories. RESULTS: There were two cortical breaching screws in stage one and three in stage two, but only the cortical breaching screws in stage one were ranked critical. In stage two, the planned entry points and the transverse angles of the anterior C2 screws could be simulated, whereas the declination angles could not be simulated due to intraoperative blockage of the drill bit and screwdriver by the upper teeth. CONCLUSIONS: It was feasible to use individualized templates to guide transoral C2 screw placement. Thus, these drill templates combined with transoral atlantoaxial reduction plate-IV, may improve the accuracy of transoral C2 screw placement and reduce related neurovascular complications.
publishDate 2014
dc.date.none.fl_str_mv 2014-11-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/clinics/article/view/96915
10.6061/clinics/2014(11)08
url https://www.revistas.usp.br/clinics/article/view/96915
identifier_str_mv 10.6061/clinics/2014(11)08
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/clinics/article/view/96915/95995
dc.rights.driver.fl_str_mv Copyright (c) 2015 Clinics
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2015 Clinics
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo
publisher.none.fl_str_mv Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo
dc.source.none.fl_str_mv Clinics; v. 69 n. 11 (2014); 750-757
Clinics; Vol. 69 Núm. 11 (2014); 750-757
Clinics; Vol. 69 No. 11 (2014); 750-757
1980-5322
1807-5932
reponame:Clinics
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Clinics
collection Clinics
repository.name.fl_str_mv Clinics - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||clinics@hc.fm.usp.br
_version_ 1787713178156662784