Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina

Bibliographic Details
Main Author: Giovanna Emann Tavares Menegatti
Publication Date: 2016
Format: Master thesis
Language: por
Source: Biblioteca Digital de Teses e Dissertações da USP
Download full: https://doi.org/10.11606/D.23.2016.tde-04082016-152123
Summary: A presente pesquisa se propôs a avaliar a influência de cinco tratamentos dentinários na resistência de união à dentina de quatro cimentos de ionômero de vidro modificados por resina (CIVRMs). O ensaio experimental foi realizado in vitro, fazendo uso de 200 incisivos bovinos. Destes, foram obtidos 200 fragmentos de dentina, que foram distribuídos aleatoriamente em 20 grupos (n=10), segundo os fatores de variação que compreendem cinco tratamentos dentinários (Grupo controle, ou seja, sem tratamento; Ácido Poliacrílico a 20%, Clearfil SE Bond; Single Bond Universal e Primer do Vitremer) e quatro cimentos ionoméricos (GC Fuji II LC® CAPSULE; GC Fuji LINING® LC (Paste Pak); Vitrebond® e Vitremer). Após a confecção dos corpos de prova e 24h de armazenamento em estufa à 37oC, foi realizado o teste de microcisalhamento na máquina de ensaios universal (Instron 5942 - Canton, MA, EUA) com velocidade de 1mm/min, seguido da análise do padrão de fratura em microscópio digital. A análise estatística dos 400 resultados obtidos foi feita por meio do teste paramétrico ANOVA para dois fatores de variação (cimento e tratamento) (p<0,05%) e pelo teste auxiliar de Tukey (p<0,05%). Os testes estatísticos demonstraram haver diferença estatística tanto entre os tratamentos, como entre os cimentos e na interação de ambos (p<0,0001). Os sistemas adesivos Clearfil SE (X?=18,26 ± 2,78) e SingleBond (X?=17,28 ± 2,49) promoveram os valores de resistência adesiva mais elevados em comparação aos demais tratamentos, mas sem apresentarem diferença estatística entre si, o que representou um aumento na resistência de união de 121% para o Clearfil SE e 109,2% para o Single Bond Universal em relação ao Grupo Controle. O uso do Ácido Poliacrílico (X?=9,94 ± 3,55) alcançou valores intermediários, correspondendo a um aumento de 20% na resistência adesiva em relação ao Grupo Controle. Esse tratamento se diferenciou estatisticamente dos maiores valores, porém não apresentou diferença frente ao Primer do Vitremer (X?=8,91 ± 2,97). O grupo controle (X?=8,26 ± 4,17) evidenciou os menores valores, se diferenciando estatisticamente dos sistemas adesivos e do Ácido Poliacrílico, mas com resultados que o equiparou ao tratamento com o Primer do Vitremer. Ao se analisar a interação entre cimento e tratamento, todos os cimentos de ionômero de vidro resinomodificados (CIVRMs) testados neste estudo apresentaram seus maiores resultados quando um dos sistemas adesivos foi utilizado como tratamento dentinário, independente de qual sistema adesivo. Com base nesses resultados, pôde-se concluir que os dois sistemas adesivos autocondicionantes foram capazes de melhorar significativamente a resistência adesiva dos CIVRMs.
id USP_6815ebcb18418c616da929478f55007d
oai_identifier_str oai:teses.usp.br:tde-04082016-152123
network_acronym_str USP
network_name_str Biblioteca Digital de Teses e Dissertações da USP
repository_id_str 2721
spelling info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina Influence of self-etch adhesive on bond strength of resin-modified glass ionomer to dentin 2016-05-12Miriam Lacalle TurbinoLuis Carlos BelanLeonardo Eloy Rodrigues FilhoGiovanna Emann Tavares MenegattiUniversidade de São PauloOdontologia (Dentística)USPBR cimentos de ionômero de vidro resinomodificados dentin surface treatments micro-shear bond strength microcisalhamento resin-modified glass-ionomer cement self-etch adhesive systems sistemas adesivos autocondicionantes tratamentos da superfície dentinária A presente pesquisa se propôs a avaliar a influência de cinco tratamentos dentinários na resistência de união à dentina de quatro cimentos de ionômero de vidro modificados por resina (CIVRMs). O ensaio experimental foi realizado in vitro, fazendo uso de 200 incisivos bovinos. Destes, foram obtidos 200 fragmentos de dentina, que foram distribuídos aleatoriamente em 20 grupos (n=10), segundo os fatores de variação que compreendem cinco tratamentos dentinários (Grupo controle, ou seja, sem tratamento; Ácido Poliacrílico a 20%, Clearfil SE Bond; Single Bond Universal e Primer do Vitremer) e quatro cimentos ionoméricos (GC Fuji II LC® CAPSULE; GC Fuji LINING® LC (Paste Pak); Vitrebond® e Vitremer). Após a confecção dos corpos de prova e 24h de armazenamento em estufa à 37oC, foi realizado o teste de microcisalhamento na máquina de ensaios universal (Instron 5942 - Canton, MA, EUA) com velocidade de 1mm/min, seguido da análise do padrão de fratura em microscópio digital. A análise estatística dos 400 resultados obtidos foi feita por meio do teste paramétrico ANOVA para dois fatores de variação (cimento e tratamento) (p<0,05%) e pelo teste auxiliar de Tukey (p<0,05%). Os testes estatísticos demonstraram haver diferença estatística tanto entre os tratamentos, como entre os cimentos e na interação de ambos (p<0,0001). Os sistemas adesivos Clearfil SE (X?=18,26 ± 2,78) e SingleBond (X?=17,28 ± 2,49) promoveram os valores de resistência adesiva mais elevados em comparação aos demais tratamentos, mas sem apresentarem diferença estatística entre si, o que representou um aumento na resistência de união de 121% para o Clearfil SE e 109,2% para o Single Bond Universal em relação ao Grupo Controle. O uso do Ácido Poliacrílico (X?=9,94 ± 3,55) alcançou valores intermediários, correspondendo a um aumento de 20% na resistência adesiva em relação ao Grupo Controle. Esse tratamento se diferenciou estatisticamente dos maiores valores, porém não apresentou diferença frente ao Primer do Vitremer (X?=8,91 ± 2,97). O grupo controle (X?=8,26 ± 4,17) evidenciou os menores valores, se diferenciando estatisticamente dos sistemas adesivos e do Ácido Poliacrílico, mas com resultados que o equiparou ao tratamento com o Primer do Vitremer. Ao se analisar a interação entre cimento e tratamento, todos os cimentos de ionômero de vidro resinomodificados (CIVRMs) testados neste estudo apresentaram seus maiores resultados quando um dos sistemas adesivos foi utilizado como tratamento dentinário, independente de qual sistema adesivo. Com base nesses resultados, pôde-se concluir que os dois sistemas adesivos autocondicionantes foram capazes de melhorar significativamente a resistência adesiva dos CIVRMs. This research aims to evaluate the influence of five dentin pretreatments on microshear bond strength of four resin-modified glass ionomer (RMGI). The experiment was performed in vitro, using 200 bovine incisors. From these, there were obtained 200 dentine fragments that were randomly distributed into 20 groups (n = 10) according to the variation factors comprising five dentin treatment (control group, i.e., no treatment; Polyacrylic Acid 20%; Clearfil SE Bond; Single Bond Universal and Vitremer Primer) and four glass ionomer cements (GC Fuji II LC® CAPSULE; GC Fuji LC LINING® (Paste Pak); Vitrebond® and Vitremer). After preparation of the samples and 24h storage at 37 °C, was performed microshear test in a universal testing machine (Instron 5942 - Canton, MA, USA) with speed of 1mm/min, followed by analysis of the pattern fractures in digital microscope. Statistical analysis of the 400 results was performed by ANOVA nonparametric test for two variation factors (cement and treatment) (p <0.05%) and the post-hoc Tukey (p <0.05%). The tests demonstrated there are statistical difference between treatments, cements and between the interaction of both (p <0.0001). The Clearfil SE (X?=18,26 ± 2,78) and SingleBond (X?=17,28 ± 2,49) promoted the highest bond strength values compared to the other treatments, but showing no statistical difference between them, which represented an increase in bond strength of 121% for Clearfil SE and 109.2% for Single Bond Universal compared to control group. The Polyacrylic Acid (X?=9,94 ± 3,55) has reached intermediate values, corresponding to a 20% increase in adhesive strength compared to control group. This treatment differed significantly from the higher values, but showed no difference compared to Primer Vitremer (X?=8,91 ± 2,97). The control group (X?=8,26 ± 4,17) showed the lowest values, statistically differing from the adhesives and polyacrylic acid, but with results that matched to the treatment with Vitremer Primer. When analyzing the interaction between cement and treatment, all cements tested in this study had higher results when one of the adhesive systems was used as dentin treatment, regardless of which adhesive system. Based on these results, it could be concluded that the two adhesive systems were able to significantly improve the adhesive strength of RMGIs. https://doi.org/10.11606/D.23.2016.tde-04082016-152123info:eu-repo/semantics/openAccessporreponame:Biblioteca Digital de Teses e Dissertações da USPinstname:Universidade de São Paulo (USP)instacron:USP2023-12-21T18:12:22Zoai:teses.usp.br:tde-04082016-152123Biblioteca Digital de Teses e Dissertaçõeshttp://www.teses.usp.br/PUBhttp://www.teses.usp.br/cgi-bin/mtd2br.plvirginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.bropendoar:27212023-12-22T12:07:16.825548Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)false
dc.title.pt.fl_str_mv Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina
dc.title.alternative.en.fl_str_mv Influence of self-etch adhesive on bond strength of resin-modified glass ionomer to dentin
title Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina
spellingShingle Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina
Giovanna Emann Tavares Menegatti
title_short Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina
title_full Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina
title_fullStr Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina
title_full_unstemmed Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina
title_sort Influência de adesivos autocondicionantes na resistência adesiva de cimentos de ionômero de vidro resinomodificados à dentina
author Giovanna Emann Tavares Menegatti
author_facet Giovanna Emann Tavares Menegatti
author_role author
dc.contributor.advisor1.fl_str_mv Miriam Lacalle Turbino
dc.contributor.referee1.fl_str_mv Luis Carlos Belan
dc.contributor.referee2.fl_str_mv Leonardo Eloy Rodrigues Filho
dc.contributor.author.fl_str_mv Giovanna Emann Tavares Menegatti
contributor_str_mv Miriam Lacalle Turbino
Luis Carlos Belan
Leonardo Eloy Rodrigues Filho
description A presente pesquisa se propôs a avaliar a influência de cinco tratamentos dentinários na resistência de união à dentina de quatro cimentos de ionômero de vidro modificados por resina (CIVRMs). O ensaio experimental foi realizado in vitro, fazendo uso de 200 incisivos bovinos. Destes, foram obtidos 200 fragmentos de dentina, que foram distribuídos aleatoriamente em 20 grupos (n=10), segundo os fatores de variação que compreendem cinco tratamentos dentinários (Grupo controle, ou seja, sem tratamento; Ácido Poliacrílico a 20%, Clearfil SE Bond; Single Bond Universal e Primer do Vitremer) e quatro cimentos ionoméricos (GC Fuji II LC® CAPSULE; GC Fuji LINING® LC (Paste Pak); Vitrebond® e Vitremer). Após a confecção dos corpos de prova e 24h de armazenamento em estufa à 37oC, foi realizado o teste de microcisalhamento na máquina de ensaios universal (Instron 5942 - Canton, MA, EUA) com velocidade de 1mm/min, seguido da análise do padrão de fratura em microscópio digital. A análise estatística dos 400 resultados obtidos foi feita por meio do teste paramétrico ANOVA para dois fatores de variação (cimento e tratamento) (p<0,05%) e pelo teste auxiliar de Tukey (p<0,05%). Os testes estatísticos demonstraram haver diferença estatística tanto entre os tratamentos, como entre os cimentos e na interação de ambos (p<0,0001). Os sistemas adesivos Clearfil SE (X?=18,26 ± 2,78) e SingleBond (X?=17,28 ± 2,49) promoveram os valores de resistência adesiva mais elevados em comparação aos demais tratamentos, mas sem apresentarem diferença estatística entre si, o que representou um aumento na resistência de união de 121% para o Clearfil SE e 109,2% para o Single Bond Universal em relação ao Grupo Controle. O uso do Ácido Poliacrílico (X?=9,94 ± 3,55) alcançou valores intermediários, correspondendo a um aumento de 20% na resistência adesiva em relação ao Grupo Controle. Esse tratamento se diferenciou estatisticamente dos maiores valores, porém não apresentou diferença frente ao Primer do Vitremer (X?=8,91 ± 2,97). O grupo controle (X?=8,26 ± 4,17) evidenciou os menores valores, se diferenciando estatisticamente dos sistemas adesivos e do Ácido Poliacrílico, mas com resultados que o equiparou ao tratamento com o Primer do Vitremer. Ao se analisar a interação entre cimento e tratamento, todos os cimentos de ionômero de vidro resinomodificados (CIVRMs) testados neste estudo apresentaram seus maiores resultados quando um dos sistemas adesivos foi utilizado como tratamento dentinário, independente de qual sistema adesivo. Com base nesses resultados, pôde-se concluir que os dois sistemas adesivos autocondicionantes foram capazes de melhorar significativamente a resistência adesiva dos CIVRMs.
publishDate 2016
dc.date.issued.fl_str_mv 2016-05-12
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.11606/D.23.2016.tde-04082016-152123
url https://doi.org/10.11606/D.23.2016.tde-04082016-152123
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade de São Paulo
dc.publisher.program.fl_str_mv Odontologia (Dentística)
dc.publisher.initials.fl_str_mv USP
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv Universidade de São Paulo
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da USP
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Biblioteca Digital de Teses e Dissertações da USP
collection Biblioteca Digital de Teses e Dissertações da USP
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da USP - Universidade de São Paulo (USP)
repository.mail.fl_str_mv virginia@if.usp.br|| atendimento@aguia.usp.br||virginia@if.usp.br
_version_ 1794502460609396736