Finite Element Analysis applied to Electromagnetic Forces calculation on Power Transformers

Detalhes bibliográficos
Autor(a) principal: Medeiros, Leonardo Hautrive
Data de Publicação: 2021
Outros Autores: Maschio, Guilherme, Oliveira, Micael Marcio, Kaminski Júnior, Antônio Mário, Bueno, Daniela Maia, Bender, Vitor Cristiano, Marchesan, Tiago Bandeira
Tipo de documento: Artigo de conferência
Idioma: eng
Título da fonte: Manancial - Repositório Digital da UFSM
Texto Completo: http://repositorio.ufsm.br/handle/1/21791
Resumo: High electromagnetic forces on power transformers windings may cause the equipment unavailability, resulting in technical and financial losses. To ensure its reliability, transformers must withstand the mechanical stresses demanded by the operation conditions. Once forces measurement and determination have a high degree of complexity, it is needed tools that support forces calculation and analysis accurately. This paper presents the Finite Element Analysis (FEA) applied to determine the electromagnetic forces and its distribution on transformer windings. A complete and close to the practice modeling is done, considering the magnetic core and lateral phases presence in a 3D and 3-phase configuration. The total, radial and axial forces over the windings, as well as its distribution around the core column and along its height are determined on the three phases. With precision and versatility, FEA may be widely applied by industry, contributing for more reliable transformers designs and in cost reduction. https://doi.org/10.53316/sepoc2021.039
id UFSM_6fe8a8029e72752672ac54dd34bb33f8
oai_identifier_str oai:repositorio.ufsm.br:1/21791
network_acronym_str UFSM
network_name_str Manancial - Repositório Digital da UFSM
repository_id_str
spelling Finite Element Analysis applied to Electromagnetic Forces calculation on Power TransformersElectromagnetic ForcesFinite Element AnalysisPower TransformersShort-circuitTransformer DesignCNPQ::ENGENHARIAS::ENGENHARIA ELETRICAHigh electromagnetic forces on power transformers windings may cause the equipment unavailability, resulting in technical and financial losses. To ensure its reliability, transformers must withstand the mechanical stresses demanded by the operation conditions. Once forces measurement and determination have a high degree of complexity, it is needed tools that support forces calculation and analysis accurately. This paper presents the Finite Element Analysis (FEA) applied to determine the electromagnetic forces and its distribution on transformer windings. A complete and close to the practice modeling is done, considering the magnetic core and lateral phases presence in a 3D and 3-phase configuration. The total, radial and axial forces over the windings, as well as its distribution around the core column and along its height are determined on the three phases. With precision and versatility, FEA may be widely applied by industry, contributing for more reliable transformers designs and in cost reduction. https://doi.org/10.53316/sepoc2021.039Brasil2021-08-07T20:55:05Z2021-08-07T20:55:05Z2021-05-18info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObjectapplication/pdfhttp://repositorio.ufsm.br/handle/1/21791engSEPOC 2021Attribution-NonCommercial-NoDerivatives 4.0 Internationalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessMedeiros, Leonardo HautriveMaschio, GuilhermeOliveira, Micael MarcioKaminski Júnior, Antônio MárioBueno, Daniela MaiaBender, Vitor CristianoMarchesan, Tiago Bandeirareponame:Manancial - Repositório Digital da UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSM2022-06-27T14:06:48Zoai:repositorio.ufsm.br:1/21791Biblioteca Digital de Teses e Dissertaçõeshttps://repositorio.ufsm.br/ONGhttps://repositorio.ufsm.br/oai/requestatendimento.sib@ufsm.br||tedebc@gmail.comopendoar:2022-06-27T14:06:48Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)false
dc.title.none.fl_str_mv Finite Element Analysis applied to Electromagnetic Forces calculation on Power Transformers
title Finite Element Analysis applied to Electromagnetic Forces calculation on Power Transformers
spellingShingle Finite Element Analysis applied to Electromagnetic Forces calculation on Power Transformers
Medeiros, Leonardo Hautrive
Electromagnetic Forces
Finite Element Analysis
Power Transformers
Short-circuit
Transformer Design
CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA
title_short Finite Element Analysis applied to Electromagnetic Forces calculation on Power Transformers
title_full Finite Element Analysis applied to Electromagnetic Forces calculation on Power Transformers
title_fullStr Finite Element Analysis applied to Electromagnetic Forces calculation on Power Transformers
title_full_unstemmed Finite Element Analysis applied to Electromagnetic Forces calculation on Power Transformers
title_sort Finite Element Analysis applied to Electromagnetic Forces calculation on Power Transformers
author Medeiros, Leonardo Hautrive
author_facet Medeiros, Leonardo Hautrive
Maschio, Guilherme
Oliveira, Micael Marcio
Kaminski Júnior, Antônio Mário
Bueno, Daniela Maia
Bender, Vitor Cristiano
Marchesan, Tiago Bandeira
author_role author
author2 Maschio, Guilherme
Oliveira, Micael Marcio
Kaminski Júnior, Antônio Mário
Bueno, Daniela Maia
Bender, Vitor Cristiano
Marchesan, Tiago Bandeira
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Medeiros, Leonardo Hautrive
Maschio, Guilherme
Oliveira, Micael Marcio
Kaminski Júnior, Antônio Mário
Bueno, Daniela Maia
Bender, Vitor Cristiano
Marchesan, Tiago Bandeira
dc.subject.por.fl_str_mv Electromagnetic Forces
Finite Element Analysis
Power Transformers
Short-circuit
Transformer Design
CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA
topic Electromagnetic Forces
Finite Element Analysis
Power Transformers
Short-circuit
Transformer Design
CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA
description High electromagnetic forces on power transformers windings may cause the equipment unavailability, resulting in technical and financial losses. To ensure its reliability, transformers must withstand the mechanical stresses demanded by the operation conditions. Once forces measurement and determination have a high degree of complexity, it is needed tools that support forces calculation and analysis accurately. This paper presents the Finite Element Analysis (FEA) applied to determine the electromagnetic forces and its distribution on transformer windings. A complete and close to the practice modeling is done, considering the magnetic core and lateral phases presence in a 3D and 3-phase configuration. The total, radial and axial forces over the windings, as well as its distribution around the core column and along its height are determined on the three phases. With precision and versatility, FEA may be widely applied by industry, contributing for more reliable transformers designs and in cost reduction. https://doi.org/10.53316/sepoc2021.039
publishDate 2021
dc.date.none.fl_str_mv 2021-08-07T20:55:05Z
2021-08-07T20:55:05Z
2021-05-18
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/conferenceObject
format conferenceObject
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.ufsm.br/handle/1/21791
url http://repositorio.ufsm.br/handle/1/21791
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv SEPOC 2021
dc.rights.driver.fl_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Brasil
publisher.none.fl_str_mv Brasil
dc.source.none.fl_str_mv reponame:Manancial - Repositório Digital da UFSM
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Manancial - Repositório Digital da UFSM
collection Manancial - Repositório Digital da UFSM
repository.name.fl_str_mv Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)
repository.mail.fl_str_mv atendimento.sib@ufsm.br||tedebc@gmail.com
_version_ 1805922057069789184