Resumo: The use of residues, as the rice husk ash (RHA) in the concrete s production reduces the environmental impact caused in its productive chain. It means fewer energy s consumption, fewer natural resources waste, less environmental pollution and lower aggregated cost. In the present study, the viability of using residual RHA, in natura (non-ground) or ground, on structural concrete, in partial substitution to the Portland cement was investigated, starting from the durability chloride ions analysis. In such a way, five cementitious blends, two composed by natural RHA, two with crushed RHA and one as a reference sample were tested. The substitution s rates were 15% and 25%. The water/binder relations used were 0.45, 0.55 and 0.65. The samples were tested for chloride penetration according to ASTM C 1202 (Rapid Chloride Permeability Test) and for long-term test (colorimetric method). Additionally, the tests of axial compressive strength and water absorption by immersion, according to the ABNT prescriptions were conducted. The obtained results showed that is viable to use residual non-ground RHA as partial substitution to Portland cement in structural concretes. For the axial compressive strength at 91 days and to the same relation w/b, in general, the residual non-ground RHA blends showed higher performance than those presented by the reference mixture. In the RCPT the use of RHA resulted in decreases in the passing charges that, in general, promoted improvement in the mixtures ratings on the chloride penetrability, compared with the reference mixtures. In long-term test, the use of RHA burnt without temperature control, also promoted improvements in the mixture performances, compared to the reference mixtures, with reductions in the chloride penetration coefficients. But the mixtures were dissimilar when compared to those presented by the RCPT. In the case of water absorption by immersion, it was found that the use of RHA, in general, increased the concrete water absorption, however, the results presented by mixtures composed with RHA were close to those of reference ones.
id UFSM_809851c2c78c2fe638772575145b6e44
oai_identifier_str oai:repositorio.ufsm.br:1/7697
network_acronym_str UFSM
network_name_str Manancial - Repositório Digital da UFSM
repository_id_str
spelling Estudo da utilização de cinza da casca do arroz residual em concretos estruturais: uma análise da durabilidade aos cloretosUtilization study of residual rice rusk ash in structural concrete: an analysis of the chloride durabilityConcretoCinza de casca de arrozResistência à compressão axialPenetração de cloretosAbsorção de água por imersãoConcreteChloride penetrationAxial compressive strengthWater absorptionRice husk ashCNPQ::ENGENHARIAS::ENGENHARIA CIVILThe use of residues, as the rice husk ash (RHA) in the concrete s production reduces the environmental impact caused in its productive chain. It means fewer energy s consumption, fewer natural resources waste, less environmental pollution and lower aggregated cost. In the present study, the viability of using residual RHA, in natura (non-ground) or ground, on structural concrete, in partial substitution to the Portland cement was investigated, starting from the durability chloride ions analysis. In such a way, five cementitious blends, two composed by natural RHA, two with crushed RHA and one as a reference sample were tested. The substitution s rates were 15% and 25%. The water/binder relations used were 0.45, 0.55 and 0.65. The samples were tested for chloride penetration according to ASTM C 1202 (Rapid Chloride Permeability Test) and for long-term test (colorimetric method). Additionally, the tests of axial compressive strength and water absorption by immersion, according to the ABNT prescriptions were conducted. The obtained results showed that is viable to use residual non-ground RHA as partial substitution to Portland cement in structural concretes. For the axial compressive strength at 91 days and to the same relation w/b, in general, the residual non-ground RHA blends showed higher performance than those presented by the reference mixture. In the RCPT the use of RHA resulted in decreases in the passing charges that, in general, promoted improvement in the mixtures ratings on the chloride penetrability, compared with the reference mixtures. In long-term test, the use of RHA burnt without temperature control, also promoted improvements in the mixture performances, compared to the reference mixtures, with reductions in the chloride penetration coefficients. But the mixtures were dissimilar when compared to those presented by the RCPT. In the case of water absorption by immersion, it was found that the use of RHA, in general, increased the concrete water absorption, however, the results presented by mixtures composed with RHA were close to those of reference ones.A utilização de resíduos como a cinza da casca do arroz produzida sem controle da temperatura na fabricação de concretos reduz o impacto ambiental gerado na cadeia produtiva deste material, significando menor consumo de energia, menor desperdício de recursos naturais, menor poluição do meio ambiente e menor custo agregado. No presente trabalho investiga-se a viabilidade de se utilizar a CCA residual, ao natural ou moída, em concretos estruturais, em substituição parcial ao cimento Portland, a partir da análise da durabilidade aos ions cloretos. Para isso, foram testadas cinco misturas aglomerantes: duas compostas com CCA ao natural, duas com CCA moída e uma mistura de referência com 100% cimento Portland, a qual se confrontaram os resultados. Adotaram-se os teores de substituição de 15% e 25%, e as relações a/ag de 0,45; 0,55 e 0,65. Procederam-se os ensaios de resistência à penetração de cloretos segundo o método de penetração acelerada ASTM C 1202 (EAPC) e também, segundo o método de imersão em solução salina (EPCI). Adicionalmente, foram realizados os ensaios de resistência à compressão axial e de absorção de água por imersão, segundo prescrições da ABNT. Os resultados obtidos na investigação confirmam que é viável utilizar a CCA residual, ao natural ou moída, como substituição parcial ao cimento Portland, em concretos para uso estrutural. Quanto à resistência a compressão axial, aos 91 dias, as misturas compostas CCA, em geral, apresentaram desempenhos superiores aos das misturas de referência. No EAPC a utilização de CCA resultou em decréscimos nos valores das cargas passantes que, em geral, promoveram melhoria nas classificações das misturas quanto à penetrabilidade aos cloretos, em comparação as misturas de referência. No EPCI a utilização da CCA, queimada sem controle de temperatura, também promoveu melhorias no desempenho da maioria das misturas, em comparação às misturas de referência, com reduções nos coeficientes de penetração de cloretos. Porém as misturas apresentaram comportamentos diferenciados quando comparados ao apresentado no EAPC. No caso da absorção de água por imersão, constatou-se que a utilização de CCA, em geral, aumentou a absorção de água dos concretos, entretanto, os valores apresentados pelas misturas compostas com CCA foram próximos aos de referência.Universidade Federal de Santa MariaBREngenharia CivilUFSMPrograma de Pós-Graduação em Engenharia CivilGastaldini, Antonio Luiz Guerrahttp://lattes.cnpq.br/9293085240832049Isaia, Geraldo Cechellahttp://lattes.cnpq.br/8260652949733370Cremonini, Ruy Albertohttp://lattes.cnpq.br/7134373859893235Pedrozo, Eder Claro2008-07-182008-07-182008-03-27info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfapplication/pdfPEDROZO, Eder Claro. Utilization study of residual rice rusk ash in structural concrete: an analysis of the chloride durability. 2008. 143 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal de Santa Maria, Santa Maria, 2008.http://repositorio.ufsm.br/handle/1/7697porinfo:eu-repo/semantics/openAccessreponame:Manancial - Repositório Digital da UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSM2022-01-26T17:18:38Zoai:repositorio.ufsm.br:1/7697Biblioteca Digital de Teses e Dissertaçõeshttps://repositorio.ufsm.br/ONGhttps://repositorio.ufsm.br/oai/requestatendimento.sib@ufsm.br||tedebc@gmail.comopendoar:2022-01-26T17:18:38Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)false
dc.title.none.fl_str_mv Estudo da utilização de cinza da casca do arroz residual em concretos estruturais: uma análise da durabilidade aos cloretos
Utilization study of residual rice rusk ash in structural concrete: an analysis of the chloride durability
title Estudo da utilização de cinza da casca do arroz residual em concretos estruturais: uma análise da durabilidade aos cloretos
spellingShingle Estudo da utilização de cinza da casca do arroz residual em concretos estruturais: uma análise da durabilidade aos cloretos
Pedrozo, Eder Claro
Concreto
Cinza de casca de arroz
Resistência à compressão axial
Penetração de cloretos
Absorção de água por imersão
Concrete
Chloride penetration
Axial compressive strength
Water absorption
Rice husk ash
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
title_short Estudo da utilização de cinza da casca do arroz residual em concretos estruturais: uma análise da durabilidade aos cloretos
title_full Estudo da utilização de cinza da casca do arroz residual em concretos estruturais: uma análise da durabilidade aos cloretos
title_fullStr Estudo da utilização de cinza da casca do arroz residual em concretos estruturais: uma análise da durabilidade aos cloretos
title_full_unstemmed Estudo da utilização de cinza da casca do arroz residual em concretos estruturais: uma análise da durabilidade aos cloretos
title_sort Estudo da utilização de cinza da casca do arroz residual em concretos estruturais: uma análise da durabilidade aos cloretos
author Pedrozo, Eder Claro
author_facet Pedrozo, Eder Claro
author_role author
dc.contributor.none.fl_str_mv Gastaldini, Antonio Luiz Guerra
http://lattes.cnpq.br/9293085240832049
Isaia, Geraldo Cechella
http://lattes.cnpq.br/8260652949733370
Cremonini, Ruy Alberto
http://lattes.cnpq.br/7134373859893235
dc.contributor.author.fl_str_mv Pedrozo, Eder Claro
dc.subject.por.fl_str_mv Concreto
Cinza de casca de arroz
Resistência à compressão axial
Penetração de cloretos
Absorção de água por imersão
Concrete
Chloride penetration
Axial compressive strength
Water absorption
Rice husk ash
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
topic Concreto
Cinza de casca de arroz
Resistência à compressão axial
Penetração de cloretos
Absorção de água por imersão
Concrete
Chloride penetration
Axial compressive strength
Water absorption
Rice husk ash
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
description The use of residues, as the rice husk ash (RHA) in the concrete s production reduces the environmental impact caused in its productive chain. It means fewer energy s consumption, fewer natural resources waste, less environmental pollution and lower aggregated cost. In the present study, the viability of using residual RHA, in natura (non-ground) or ground, on structural concrete, in partial substitution to the Portland cement was investigated, starting from the durability chloride ions analysis. In such a way, five cementitious blends, two composed by natural RHA, two with crushed RHA and one as a reference sample were tested. The substitution s rates were 15% and 25%. The water/binder relations used were 0.45, 0.55 and 0.65. The samples were tested for chloride penetration according to ASTM C 1202 (Rapid Chloride Permeability Test) and for long-term test (colorimetric method). Additionally, the tests of axial compressive strength and water absorption by immersion, according to the ABNT prescriptions were conducted. The obtained results showed that is viable to use residual non-ground RHA as partial substitution to Portland cement in structural concretes. For the axial compressive strength at 91 days and to the same relation w/b, in general, the residual non-ground RHA blends showed higher performance than those presented by the reference mixture. In the RCPT the use of RHA resulted in decreases in the passing charges that, in general, promoted improvement in the mixtures ratings on the chloride penetrability, compared with the reference mixtures. In long-term test, the use of RHA burnt without temperature control, also promoted improvements in the mixture performances, compared to the reference mixtures, with reductions in the chloride penetration coefficients. But the mixtures were dissimilar when compared to those presented by the RCPT. In the case of water absorption by immersion, it was found that the use of RHA, in general, increased the concrete water absorption, however, the results presented by mixtures composed with RHA were close to those of reference ones.
publishDate 2008
dc.date.none.fl_str_mv 2008-07-18
2008-07-18
2008-03-27
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv PEDROZO, Eder Claro. Utilization study of residual rice rusk ash in structural concrete: an analysis of the chloride durability. 2008. 143 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal de Santa Maria, Santa Maria, 2008.
http://repositorio.ufsm.br/handle/1/7697
identifier_str_mv PEDROZO, Eder Claro. Utilization study of residual rice rusk ash in structural concrete: an analysis of the chloride durability. 2008. 143 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal de Santa Maria, Santa Maria, 2008.
url http://repositorio.ufsm.br/handle/1/7697
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
BR
Engenharia Civil
UFSM
Programa de Pós-Graduação em Engenharia Civil
publisher.none.fl_str_mv Universidade Federal de Santa Maria
BR
Engenharia Civil
UFSM
Programa de Pós-Graduação em Engenharia Civil
dc.source.none.fl_str_mv reponame:Manancial - Repositório Digital da UFSM
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Manancial - Repositório Digital da UFSM
collection Manancial - Repositório Digital da UFSM
repository.name.fl_str_mv Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)
repository.mail.fl_str_mv atendimento.sib@ufsm.br||tedebc@gmail.com
_version_ 1805922086277873664