Proposta de estratégias para climatização passiva para as salas de aula do Centro de Tecnologia da UFSM

Detalhes bibliográficos
Autor(a) principal: Saad, Denise de Souza
Data de Publicação: 2018
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Manancial - Repositório Digital da UFSM
dARK ID: ark:/26339/00130000083wd
Texto Completo: http://repositorio.ufsm.br/handle/1/14939
Resumo: In this work, passive strategies for air conditioning in the classrooms of the UFSM Technology Center were evaluated. In this work, the topic to be developed, the general and specific objectives, the justification and the work structure were presented. Afterwards, a review was made regarding the subject, describing the history of sustainability and the existing certifications, the panorama of the electric sector, the energy efficiency and the Procel Seal, besides addressing the computational simulation and the EnergyPlus program. In the methodology, it was initially determined the rooms that would be evaluated, room 236, located on the second floor and room 301, located on the third floor, under the critical conditions indicated by the norm NBR 15575(2013). Room 236 was evaluated for the winter period and the solution was the use of double glass miter. For room 301 were evaluated the use of ventilation, thermal insulation of the roof, roofing with metallic tile and sun protection. For room 236 the best result was the one that used double glazing, employing 3mm smooth colorless glass, with thermal transmittance of 2,731 W / m2K, without infiltration. For room 301, the best solution was the use of thermal insulation in the roof slab, with thermal transmittance of 0.621 W / m2K, ventilation of 15 air changes per hour and the use of solar protection on the west wall and metal roofing = 0.15. The energy consumption for the solutions was also evaluated, where the best solution for room 236 brought a reduction in energy consumption of 36% and for room 301 the reduction was of 22%. Another analysis was the fulfillment of the criterion of performance of NBR 15575 (2013) after passive strategies, room 236 performs superior performance and room 301 presents intermediate performance. At the end of the paper, the conclusions and proposals for future work were presented.
id UFSM_975849f11ac1701152e8bfae2f921af6
oai_identifier_str oai:repositorio.ufsm.br:1/14939
network_acronym_str UFSM
network_name_str Manancial - Repositório Digital da UFSM
repository_id_str
spelling Proposta de estratégias para climatização passiva para as salas de aula do Centro de Tecnologia da UFSMProposal of strategies for passive climatization for the classrooms of the Technology Center from UFSMClimatização passivaSalas de aulaDesempenhoNBR 15575Passive acclimationClassroomsPerformanceCNPQ::ENGENHARIAS::ENGENHARIA CIVILIn this work, passive strategies for air conditioning in the classrooms of the UFSM Technology Center were evaluated. In this work, the topic to be developed, the general and specific objectives, the justification and the work structure were presented. Afterwards, a review was made regarding the subject, describing the history of sustainability and the existing certifications, the panorama of the electric sector, the energy efficiency and the Procel Seal, besides addressing the computational simulation and the EnergyPlus program. In the methodology, it was initially determined the rooms that would be evaluated, room 236, located on the second floor and room 301, located on the third floor, under the critical conditions indicated by the norm NBR 15575(2013). Room 236 was evaluated for the winter period and the solution was the use of double glass miter. For room 301 were evaluated the use of ventilation, thermal insulation of the roof, roofing with metallic tile and sun protection. For room 236 the best result was the one that used double glazing, employing 3mm smooth colorless glass, with thermal transmittance of 2,731 W / m2K, without infiltration. For room 301, the best solution was the use of thermal insulation in the roof slab, with thermal transmittance of 0.621 W / m2K, ventilation of 15 air changes per hour and the use of solar protection on the west wall and metal roofing = 0.15. The energy consumption for the solutions was also evaluated, where the best solution for room 236 brought a reduction in energy consumption of 36% and for room 301 the reduction was of 22%. Another analysis was the fulfillment of the criterion of performance of NBR 15575 (2013) after passive strategies, room 236 performs superior performance and room 301 presents intermediate performance. At the end of the paper, the conclusions and proposals for future work were presented.Neste trabalho foram avaliadas estratégias passivas para climatização das salas de aula do Centro de Tecnologia da UFSM. Inicialmente foram apresentados o tema a ser desenvolvido, os objetivos geral e específicos, a justificativa e a estrutura do trabalho. Após, procedeu-se a revisão referente ao assunto, descrevendo o histórico da sustentabilidade e as certificações existentes, o panorama do setor elétrico, a eficiência energética e o Selo Procel, além de abordar a simulação computacional e o programa Energyplus. Na metodologia, inicialmente foram determinadas as salas que seriam avaliadas, a sala 236, localizada no segundo pavimento e a sala 301, localizada no terceiro pavimento, nas condições críticas indicadas pela norma NBR 15575 (2013). A sala 236 foi avaliada para o período de inverno e a solução foi o emprego de esquadria de vidro duplo. Para a sala 301 foi avaliado o emprego de ventilação, isolamento térmico da cobertura, cobertura com telha metálica e proteção solar. Para a sala 236 o melhor resultado foi aquele que empregou esquadria com vidro duplo, empregando vidro incolor liso de 3 mm, com transmitância térmica de 2,731 W/m2K, sem infiltração. Para a sala 301, a melhor solução foi o emprego de isolamento térmico na laje de cobertura, com transmitância térmica de 0,621 W/m2K, ventilação de 15 renovações de ar por hora e o uso de proteção solar na parede oeste e telhas metálicas com = 0,15. Também foram avaliados o consumo de energia para as soluções, onde a melhor solução para a sala 236 trouxe uma redução do consumo energético de 36% e para a sala 301 a redução foi de 22%. Outra análise realizada foi o atendimento ao critério de desempenho da norma NBR 15575 (2013), após o emprego das estratégias passivas, a sala 236 apresenta desempenho superior e a sala 301 apresenta o desempenho intermediário. Ao final do trabalho foram apresentadas as conclusões e propostas para futuros trabalhos.Universidade Federal de Santa MariaBrasilEngenharia CivilUFSMPrograma de Pós-Graduação em Engenharia CivilCentro de TecnologiaSantos, Joaquim Cesar Pizzutti doshttp://lattes.cnpq.br/6591314076760539Pereira, Clarissa de Oliveirahttp://lattes.cnpq.br/1952567883594336Lopes, Caryl Eduardo Jovanovichhttp://lattes.cnpq.br/0701827238095286Saad, Denise de Souza2018-11-26T17:24:00Z2018-11-26T17:24:00Z2018-08-31info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://repositorio.ufsm.br/handle/1/14939ark:/26339/00130000083wdporAttribution-NonCommercial-NoDerivatives 4.0 Internationalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessreponame:Manancial - Repositório Digital da UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSM2018-11-27T05:01:01Zoai:repositorio.ufsm.br:1/14939Biblioteca Digital de Teses e Dissertaçõeshttps://repositorio.ufsm.br/ONGhttps://repositorio.ufsm.br/oai/requestatendimento.sib@ufsm.br||tedebc@gmail.comopendoar:2018-11-27T05:01:01Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)false
dc.title.none.fl_str_mv Proposta de estratégias para climatização passiva para as salas de aula do Centro de Tecnologia da UFSM
Proposal of strategies for passive climatization for the classrooms of the Technology Center from UFSM
title Proposta de estratégias para climatização passiva para as salas de aula do Centro de Tecnologia da UFSM
spellingShingle Proposta de estratégias para climatização passiva para as salas de aula do Centro de Tecnologia da UFSM
Saad, Denise de Souza
Climatização passiva
Salas de aula
Desempenho
NBR 15575
Passive acclimation
Classrooms
Performance
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
title_short Proposta de estratégias para climatização passiva para as salas de aula do Centro de Tecnologia da UFSM
title_full Proposta de estratégias para climatização passiva para as salas de aula do Centro de Tecnologia da UFSM
title_fullStr Proposta de estratégias para climatização passiva para as salas de aula do Centro de Tecnologia da UFSM
title_full_unstemmed Proposta de estratégias para climatização passiva para as salas de aula do Centro de Tecnologia da UFSM
title_sort Proposta de estratégias para climatização passiva para as salas de aula do Centro de Tecnologia da UFSM
author Saad, Denise de Souza
author_facet Saad, Denise de Souza
author_role author
dc.contributor.none.fl_str_mv Santos, Joaquim Cesar Pizzutti dos
http://lattes.cnpq.br/6591314076760539
Pereira, Clarissa de Oliveira
http://lattes.cnpq.br/1952567883594336
Lopes, Caryl Eduardo Jovanovich
http://lattes.cnpq.br/0701827238095286
dc.contributor.author.fl_str_mv Saad, Denise de Souza
dc.subject.por.fl_str_mv Climatização passiva
Salas de aula
Desempenho
NBR 15575
Passive acclimation
Classrooms
Performance
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
topic Climatização passiva
Salas de aula
Desempenho
NBR 15575
Passive acclimation
Classrooms
Performance
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
description In this work, passive strategies for air conditioning in the classrooms of the UFSM Technology Center were evaluated. In this work, the topic to be developed, the general and specific objectives, the justification and the work structure were presented. Afterwards, a review was made regarding the subject, describing the history of sustainability and the existing certifications, the panorama of the electric sector, the energy efficiency and the Procel Seal, besides addressing the computational simulation and the EnergyPlus program. In the methodology, it was initially determined the rooms that would be evaluated, room 236, located on the second floor and room 301, located on the third floor, under the critical conditions indicated by the norm NBR 15575(2013). Room 236 was evaluated for the winter period and the solution was the use of double glass miter. For room 301 were evaluated the use of ventilation, thermal insulation of the roof, roofing with metallic tile and sun protection. For room 236 the best result was the one that used double glazing, employing 3mm smooth colorless glass, with thermal transmittance of 2,731 W / m2K, without infiltration. For room 301, the best solution was the use of thermal insulation in the roof slab, with thermal transmittance of 0.621 W / m2K, ventilation of 15 air changes per hour and the use of solar protection on the west wall and metal roofing = 0.15. The energy consumption for the solutions was also evaluated, where the best solution for room 236 brought a reduction in energy consumption of 36% and for room 301 the reduction was of 22%. Another analysis was the fulfillment of the criterion of performance of NBR 15575 (2013) after passive strategies, room 236 performs superior performance and room 301 presents intermediate performance. At the end of the paper, the conclusions and proposals for future work were presented.
publishDate 2018
dc.date.none.fl_str_mv 2018-11-26T17:24:00Z
2018-11-26T17:24:00Z
2018-08-31
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.ufsm.br/handle/1/14939
dc.identifier.dark.fl_str_mv ark:/26339/00130000083wd
url http://repositorio.ufsm.br/handle/1/14939
identifier_str_mv ark:/26339/00130000083wd
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
Brasil
Engenharia Civil
UFSM
Programa de Pós-Graduação em Engenharia Civil
Centro de Tecnologia
publisher.none.fl_str_mv Universidade Federal de Santa Maria
Brasil
Engenharia Civil
UFSM
Programa de Pós-Graduação em Engenharia Civil
Centro de Tecnologia
dc.source.none.fl_str_mv reponame:Manancial - Repositório Digital da UFSM
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Manancial - Repositório Digital da UFSM
collection Manancial - Repositório Digital da UFSM
repository.name.fl_str_mv Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)
repository.mail.fl_str_mv atendimento.sib@ufsm.br||tedebc@gmail.com
_version_ 1815172302413758464