Detection and quantification of Roundup Ready soybean residues in sausage samples by conventional and real-time PCR.

Detalhes bibliográficos
Autor(a) principal: MARCELINO-GUIMARÃES, F. C.
Data de Publicação: 2008
Outros Autores: GUIMARÃES, M. F. M., DE-BARROS, E. G.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice)
Texto Completo: http://www.alice.cnptia.embrapa.br/alice/handle/doc/471154
http://dx.doi.org/10.1590/S0101-20612008000500007
Resumo: ABSTRACT: The increasing presence of products derived from genetically modified (GM) plants in human and animal diets has led to the development of detection methods to distinguish biotechnology-derived foods from conventional ones. The conventional and real-time PCR have been used, respectively, to detect and quantify GM residues in highly processed foods. DNA extraction is a critical step during the analysis process. Some factors such as DNA degradation, matrix effects, and the presence of PCR inhibitors imply that a detection or quantification limit, established for a given method, is restricted to a matrix used during validation and cannot be projected to any other matrix outside the scope of the method. In Brazil, sausage samples were the main class of processed products in which Roundup Ready® (RR) soybean residues were detected. Thus, the validation of methodologies for the detection and quantification of those residues is absolutely necessary. Sausage samples were submitted to two different methods of DNA extraction: modified Wizard and the CTAB method. The yield and quality were compared for both methods. DNA samples were analyzed by conventional and real-time PCR for the detection and quantification of Roundup Ready® soybean in the samples. At least 200 ng of total sausage DNA was necessary for a reliable quantification. Reactions containing DNA amounts below this value led to large variations on the expected GM percentage value. In conventional PCR, the detection limit varied from 1.0 to 500 ng, depending on the GM soybean content in the sample. The precision, performance, and linearity were relatively high indicating that the method used for analysis was satisfactory. RESUMO: A presença crescente de produtos derivados de plantas geneticamente modificadas (GM) na dieta humana e de animais tem levado ao desenvolvimento de métodos de detecção capazes de distinguir entre alimentos derivados da biotecnologia e alimentos convencionais. As técnicas de PCR convencional e em tempo real têm sido as mais utilizadas para detectar e quantificar resíduos GM em alimentos altamente processados, respectivamente. A extração de DNA é um passo crítico durante o processo de análise. Alguns fatores, tais como, degradação de DNA, efeito de matriz e a presença de inibidores da PCR, implicam que um limite de detecção ou quantificação estabelecido para um determinado método é restrito à matriz usada durante validação e não pode ser estendido a qualquer outra matriz fora do escopo do método. No Brasil, amostras de salsicha constituíram a principal classe de produtos, nas quais resíduos de soja Roundup Ready® (RR) foram detectados. Então a validação de metodologias para detecção e quantificação destes resíduos é urgente. Amostras de salsicha foram submetidas a dois diferentes métodos de extração de DNA: Wizard modificado e CTAB. O rendimento e a qualidade foram comparados em ambos os métodos. As amostras foram analisadas por PCR convencional e em tempo real para detecção e quantificação de resíduos de soja RR. Pelo menos 200 ng de DNA total da amostra de salsicha foram necessários para garantir uma quantificação confiável. Reações contendo concentrações de DNA abaixo deste limite apresentaram grande variação nos valores de porcentagem de GM esperados. Na PCR convencional, o limite de detecção variou de 1,0 a 500 ng, dependendo do conteúdo de soja GM na amostra. A precisão, performance e linearidade foram relativamente altas, indicando que o método de análise foi satisfatório.
id EMBR_cb2e7e56b3ecf77e91e6b380fd576d10
oai_identifier_str oai:www.alice.cnptia.embrapa.br:doc/471154
network_acronym_str EMBR
network_name_str Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice)
repository_id_str 2154
spelling Detection and quantification of Roundup Ready soybean residues in sausage samples by conventional and real-time PCR.Planta TransgênicaSojaABSTRACT: The increasing presence of products derived from genetically modified (GM) plants in human and animal diets has led to the development of detection methods to distinguish biotechnology-derived foods from conventional ones. The conventional and real-time PCR have been used, respectively, to detect and quantify GM residues in highly processed foods. DNA extraction is a critical step during the analysis process. Some factors such as DNA degradation, matrix effects, and the presence of PCR inhibitors imply that a detection or quantification limit, established for a given method, is restricted to a matrix used during validation and cannot be projected to any other matrix outside the scope of the method. In Brazil, sausage samples were the main class of processed products in which Roundup Ready® (RR) soybean residues were detected. Thus, the validation of methodologies for the detection and quantification of those residues is absolutely necessary. Sausage samples were submitted to two different methods of DNA extraction: modified Wizard and the CTAB method. The yield and quality were compared for both methods. DNA samples were analyzed by conventional and real-time PCR for the detection and quantification of Roundup Ready® soybean in the samples. At least 200 ng of total sausage DNA was necessary for a reliable quantification. Reactions containing DNA amounts below this value led to large variations on the expected GM percentage value. In conventional PCR, the detection limit varied from 1.0 to 500 ng, depending on the GM soybean content in the sample. The precision, performance, and linearity were relatively high indicating that the method used for analysis was satisfactory. RESUMO: A presença crescente de produtos derivados de plantas geneticamente modificadas (GM) na dieta humana e de animais tem levado ao desenvolvimento de métodos de detecção capazes de distinguir entre alimentos derivados da biotecnologia e alimentos convencionais. As técnicas de PCR convencional e em tempo real têm sido as mais utilizadas para detectar e quantificar resíduos GM em alimentos altamente processados, respectivamente. A extração de DNA é um passo crítico durante o processo de análise. Alguns fatores, tais como, degradação de DNA, efeito de matriz e a presença de inibidores da PCR, implicam que um limite de detecção ou quantificação estabelecido para um determinado método é restrito à matriz usada durante validação e não pode ser estendido a qualquer outra matriz fora do escopo do método. No Brasil, amostras de salsicha constituíram a principal classe de produtos, nas quais resíduos de soja Roundup Ready® (RR) foram detectados. Então a validação de metodologias para detecção e quantificação destes resíduos é urgente. Amostras de salsicha foram submetidas a dois diferentes métodos de extração de DNA: Wizard modificado e CTAB. O rendimento e a qualidade foram comparados em ambos os métodos. As amostras foram analisadas por PCR convencional e em tempo real para detecção e quantificação de resíduos de soja RR. Pelo menos 200 ng de DNA total da amostra de salsicha foram necessários para garantir uma quantificação confiável. Reações contendo concentrações de DNA abaixo deste limite apresentaram grande variação nos valores de porcentagem de GM esperados. Na PCR convencional, o limite de detecção variou de 1,0 a 500 ng, dependendo do conteúdo de soja GM na amostra. A precisão, performance e linearidade foram relativamente altas, indicando que o método de análise foi satisfatório.FRANCISMAR CORREA MARCELINO-GUIMARÃES, CNPSO; MARTA FONSECA GUIMARÃES, CNPGL; EVERALDO GONÇALVES DE-BARROS, Bioagro/UFV.MARCELINO-GUIMARÃES, F. C.GUIMARÃES, M. F. M.DE-BARROS, E. G.2014-03-27T21:09:42Z2014-03-27T21:09:42Z2009-02-1720082014-03-27T21:09:42Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleCiência e Tecnologia de Alimentos, Campinas, v. 28, p. 38-45, 2008. Suplemento.0101-2061http://www.alice.cnptia.embrapa.br/alice/handle/doc/471154http://dx.doi.org/10.1590/S0101-20612008000500007enginfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice)instname:Empresa Brasileira de Pesquisa Agropecuária (Embrapa)instacron:EMBRAPA2017-08-16T02:01:06Zoai:www.alice.cnptia.embrapa.br:doc/471154Repositório InstitucionalPUBhttps://www.alice.cnptia.embrapa.br/oai/requestopendoar:21542017-08-16T02:01:06falseRepositório InstitucionalPUBhttps://www.alice.cnptia.embrapa.br/oai/requestcg-riaa@embrapa.bropendoar:21542017-08-16T02:01:06Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice) - Empresa Brasileira de Pesquisa Agropecuária (Embrapa)false
dc.title.none.fl_str_mv Detection and quantification of Roundup Ready soybean residues in sausage samples by conventional and real-time PCR.
title Detection and quantification of Roundup Ready soybean residues in sausage samples by conventional and real-time PCR.
spellingShingle Detection and quantification of Roundup Ready soybean residues in sausage samples by conventional and real-time PCR.
MARCELINO-GUIMARÃES, F. C.
Planta Transgênica
Soja
title_short Detection and quantification of Roundup Ready soybean residues in sausage samples by conventional and real-time PCR.
title_full Detection and quantification of Roundup Ready soybean residues in sausage samples by conventional and real-time PCR.
title_fullStr Detection and quantification of Roundup Ready soybean residues in sausage samples by conventional and real-time PCR.
title_full_unstemmed Detection and quantification of Roundup Ready soybean residues in sausage samples by conventional and real-time PCR.
title_sort Detection and quantification of Roundup Ready soybean residues in sausage samples by conventional and real-time PCR.
author MARCELINO-GUIMARÃES, F. C.
author_facet MARCELINO-GUIMARÃES, F. C.
GUIMARÃES, M. F. M.
DE-BARROS, E. G.
author_role author
author2 GUIMARÃES, M. F. M.
DE-BARROS, E. G.
author2_role author
author
dc.contributor.none.fl_str_mv FRANCISMAR CORREA MARCELINO-GUIMARÃES, CNPSO; MARTA FONSECA GUIMARÃES, CNPGL; EVERALDO GONÇALVES DE-BARROS, Bioagro/UFV.
dc.contributor.author.fl_str_mv MARCELINO-GUIMARÃES, F. C.
GUIMARÃES, M. F. M.
DE-BARROS, E. G.
dc.subject.por.fl_str_mv Planta Transgênica
Soja
topic Planta Transgênica
Soja
description ABSTRACT: The increasing presence of products derived from genetically modified (GM) plants in human and animal diets has led to the development of detection methods to distinguish biotechnology-derived foods from conventional ones. The conventional and real-time PCR have been used, respectively, to detect and quantify GM residues in highly processed foods. DNA extraction is a critical step during the analysis process. Some factors such as DNA degradation, matrix effects, and the presence of PCR inhibitors imply that a detection or quantification limit, established for a given method, is restricted to a matrix used during validation and cannot be projected to any other matrix outside the scope of the method. In Brazil, sausage samples were the main class of processed products in which Roundup Ready® (RR) soybean residues were detected. Thus, the validation of methodologies for the detection and quantification of those residues is absolutely necessary. Sausage samples were submitted to two different methods of DNA extraction: modified Wizard and the CTAB method. The yield and quality were compared for both methods. DNA samples were analyzed by conventional and real-time PCR for the detection and quantification of Roundup Ready® soybean in the samples. At least 200 ng of total sausage DNA was necessary for a reliable quantification. Reactions containing DNA amounts below this value led to large variations on the expected GM percentage value. In conventional PCR, the detection limit varied from 1.0 to 500 ng, depending on the GM soybean content in the sample. The precision, performance, and linearity were relatively high indicating that the method used for analysis was satisfactory. RESUMO: A presença crescente de produtos derivados de plantas geneticamente modificadas (GM) na dieta humana e de animais tem levado ao desenvolvimento de métodos de detecção capazes de distinguir entre alimentos derivados da biotecnologia e alimentos convencionais. As técnicas de PCR convencional e em tempo real têm sido as mais utilizadas para detectar e quantificar resíduos GM em alimentos altamente processados, respectivamente. A extração de DNA é um passo crítico durante o processo de análise. Alguns fatores, tais como, degradação de DNA, efeito de matriz e a presença de inibidores da PCR, implicam que um limite de detecção ou quantificação estabelecido para um determinado método é restrito à matriz usada durante validação e não pode ser estendido a qualquer outra matriz fora do escopo do método. No Brasil, amostras de salsicha constituíram a principal classe de produtos, nas quais resíduos de soja Roundup Ready® (RR) foram detectados. Então a validação de metodologias para detecção e quantificação destes resíduos é urgente. Amostras de salsicha foram submetidas a dois diferentes métodos de extração de DNA: Wizard modificado e CTAB. O rendimento e a qualidade foram comparados em ambos os métodos. As amostras foram analisadas por PCR convencional e em tempo real para detecção e quantificação de resíduos de soja RR. Pelo menos 200 ng de DNA total da amostra de salsicha foram necessários para garantir uma quantificação confiável. Reações contendo concentrações de DNA abaixo deste limite apresentaram grande variação nos valores de porcentagem de GM esperados. Na PCR convencional, o limite de detecção variou de 1,0 a 500 ng, dependendo do conteúdo de soja GM na amostra. A precisão, performance e linearidade foram relativamente altas, indicando que o método de análise foi satisfatório.
publishDate 2008
dc.date.none.fl_str_mv 2008
2009-02-17
2014-03-27T21:09:42Z
2014-03-27T21:09:42Z
2014-03-27T21:09:42Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv Ciência e Tecnologia de Alimentos, Campinas, v. 28, p. 38-45, 2008. Suplemento.
0101-2061
http://www.alice.cnptia.embrapa.br/alice/handle/doc/471154
http://dx.doi.org/10.1590/S0101-20612008000500007
identifier_str_mv Ciência e Tecnologia de Alimentos, Campinas, v. 28, p. 38-45, 2008. Suplemento.
0101-2061
url http://www.alice.cnptia.embrapa.br/alice/handle/doc/471154
http://dx.doi.org/10.1590/S0101-20612008000500007
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice)
instname:Empresa Brasileira de Pesquisa Agropecuária (Embrapa)
instacron:EMBRAPA
instname_str Empresa Brasileira de Pesquisa Agropecuária (Embrapa)
instacron_str EMBRAPA
institution EMBRAPA
reponame_str Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice)
collection Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice)
repository.name.fl_str_mv Repositório Institucional da EMBRAPA (Repository Open Access to Scientific Information from EMBRAPA - Alice) - Empresa Brasileira de Pesquisa Agropecuária (Embrapa)
repository.mail.fl_str_mv cg-riaa@embrapa.br
_version_ 1794503389173776384