Critical evaluation of commonly used objective functions to optimize overall quality and nutrient retention of heat-preserved foods

Detalhes bibliográficos
Autor(a) principal: Silva, C.
Data de Publicação: 1992
Outros Autores: Hendrickx, M., Oliveira, F., Tobback, P.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.14/6630
Resumo: Two objective functions—volume average retention and volume average cook-value—commonly used to optimize the overall quality and nutrient retention of heat-preserved foods, were studied and optimal processing conditions based on the two approaches were compared. Case studies from the literature were run and tested for the two objective functions. The influence of the decimal reduction time (at the reference temperature, Dref value) of the quality factor on the optimal processing temperature was evaluated. For high Dref values, e.g. for vitamins, the two objective functions give the same results and the Dref value has a minor influence on the optimum processing conditions. For low Dref values, such as for texture and colour, the optimal sterilization temperature is affected by this parameter and the use of volume average cook-value, as objective function, does not take this effect into account, which may result in underestimation of the optimal processing temperature.
id RCAP_578f8841aa61624473a60a3bfaea8f5d
oai_identifier_str oai:repositorio.ucp.pt:10400.14/6630
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Critical evaluation of commonly used objective functions to optimize overall quality and nutrient retention of heat-preserved foodsTwo objective functions—volume average retention and volume average cook-value—commonly used to optimize the overall quality and nutrient retention of heat-preserved foods, were studied and optimal processing conditions based on the two approaches were compared. Case studies from the literature were run and tested for the two objective functions. The influence of the decimal reduction time (at the reference temperature, Dref value) of the quality factor on the optimal processing temperature was evaluated. For high Dref values, e.g. for vitamins, the two objective functions give the same results and the Dref value has a minor influence on the optimum processing conditions. For low Dref values, such as for texture and colour, the optimal sterilization temperature is affected by this parameter and the use of volume average cook-value, as objective function, does not take this effect into account, which may result in underestimation of the optimal processing temperature.ElsevierVeritati - Repositório Institucional da Universidade Católica PortuguesaSilva, C.Hendrickx, M.Oliveira, F.Tobback, P.2011-10-21T10:38:54Z19921992-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.14/6630engSILVA, C....[et al] - Critical evaluation of commonly used objective functions to optimize overall quality and nutrient retention of heat-preserved foods. Journal of Food Engineering. ISSN 0260-8774. Vol. 17 n.º 4 (1992), p. 241-25810.1016/0260-8774(92)90043-6info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-12T17:11:17Zoai:repositorio.ucp.pt:10400.14/6630Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:06:18.664244Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Critical evaluation of commonly used objective functions to optimize overall quality and nutrient retention of heat-preserved foods
title Critical evaluation of commonly used objective functions to optimize overall quality and nutrient retention of heat-preserved foods
spellingShingle Critical evaluation of commonly used objective functions to optimize overall quality and nutrient retention of heat-preserved foods
Silva, C.
title_short Critical evaluation of commonly used objective functions to optimize overall quality and nutrient retention of heat-preserved foods
title_full Critical evaluation of commonly used objective functions to optimize overall quality and nutrient retention of heat-preserved foods
title_fullStr Critical evaluation of commonly used objective functions to optimize overall quality and nutrient retention of heat-preserved foods
title_full_unstemmed Critical evaluation of commonly used objective functions to optimize overall quality and nutrient retention of heat-preserved foods
title_sort Critical evaluation of commonly used objective functions to optimize overall quality and nutrient retention of heat-preserved foods
author Silva, C.
author_facet Silva, C.
Hendrickx, M.
Oliveira, F.
Tobback, P.
author_role author
author2 Hendrickx, M.
Oliveira, F.
Tobback, P.
author2_role author
author
author
dc.contributor.none.fl_str_mv Veritati - Repositório Institucional da Universidade Católica Portuguesa
dc.contributor.author.fl_str_mv Silva, C.
Hendrickx, M.
Oliveira, F.
Tobback, P.
description Two objective functions—volume average retention and volume average cook-value—commonly used to optimize the overall quality and nutrient retention of heat-preserved foods, were studied and optimal processing conditions based on the two approaches were compared. Case studies from the literature were run and tested for the two objective functions. The influence of the decimal reduction time (at the reference temperature, Dref value) of the quality factor on the optimal processing temperature was evaluated. For high Dref values, e.g. for vitamins, the two objective functions give the same results and the Dref value has a minor influence on the optimum processing conditions. For low Dref values, such as for texture and colour, the optimal sterilization temperature is affected by this parameter and the use of volume average cook-value, as objective function, does not take this effect into account, which may result in underestimation of the optimal processing temperature.
publishDate 1992
dc.date.none.fl_str_mv 1992
1992-01-01T00:00:00Z
2011-10-21T10:38:54Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.14/6630
url http://hdl.handle.net/10400.14/6630
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv SILVA, C....[et al] - Critical evaluation of commonly used objective functions to optimize overall quality and nutrient retention of heat-preserved foods. Journal of Food Engineering. ISSN 0260-8774. Vol. 17 n.º 4 (1992), p. 241-258
10.1016/0260-8774(92)90043-6
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799131729511841793