Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT

Detalhes bibliográficos
Autor(a) principal: Rodrigues, Patrícia
Data de Publicação: 2015
Outros Autores: Ferreira, Daniela Lopes, Catarino, A., Cerviño, Alejandro, Queirós, A., González-Méijome, José Manuel
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/33538
Resumo: In this study, we aimed to evaluate the intra/inter-session and intra/inter-observer variability of manual segmentation of thickness of the pre-lens tear film, contact lens (CL), post-lens tear film, epithelium, bowman’s layer, stroma and the whole cornea and CLs with a flat and a steep fit, using a commercial high-resolution spectral domain optical coherence tomographer (OCT). Two different observers obtained three repeated measures in two separate sessions. A high correlation was found between the values obtained by the two different observers, except for the thinner layers, epithelium, and Bowman’s layer. Inter-observer analysis showed a high consistency in the measurements obtained by both observers (r 2 ≥ 0.80; p < 0.001) for the thicker layers: CL, stroma, and total cornea. Intra-observer analysis of measurements obtained by each observer within the same session displayed no statistically significant differences between the three repeated measures for both observers (p > 0.05). The present results suggest that manual segmentation of anterior segment OCT images in CL wearers provides acceptable levels of repeatability between observers and between different sessions for the thinner layers, while presenting a high level of repeatability for the thicker layers.
id RCAP_eeba6946dca7aeaeb8c195d8a8dfe600
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/33538
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str
spelling Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCTOptical coherence tomographyManual layer segmentationRepeatabilityCorneal thicknessEpithelial thicknessTear film thicknessScience & TechnologyIn this study, we aimed to evaluate the intra/inter-session and intra/inter-observer variability of manual segmentation of thickness of the pre-lens tear film, contact lens (CL), post-lens tear film, epithelium, bowman’s layer, stroma and the whole cornea and CLs with a flat and a steep fit, using a commercial high-resolution spectral domain optical coherence tomographer (OCT). Two different observers obtained three repeated measures in two separate sessions. A high correlation was found between the values obtained by the two different observers, except for the thinner layers, epithelium, and Bowman’s layer. Inter-observer analysis showed a high consistency in the measurements obtained by both observers (r 2 ≥ 0.80; p < 0.001) for the thicker layers: CL, stroma, and total cornea. Intra-observer analysis of measurements obtained by each observer within the same session displayed no statistically significant differences between the three repeated measures for both observers (p > 0.05). The present results suggest that manual segmentation of anterior segment OCT images in CL wearers provides acceptable levels of repeatability between observers and between different sessions for the thinner layers, while presenting a high level of repeatability for the thicker layers.This work was supported by FEDER through the COMPETE Program and by the Portuguese Foundation for Science and Technology (FCT) in the framework of the Strategic Project PEST-C/FIS/UI607/2011. Supported in part by research grants to A. Cervino from the Universitat de Valencia (UV-AE-20070225), the "Jose Castillejo" Research Grant from the Spanish Ministry of Science and Technology (JC2008-00078) and the Spanish Network for Research in Optometry (SAF2008-01114-E).Taylor and FrancisUniversidade do MinhoRodrigues, PatríciaFerreira, Daniela LopesCatarino, A.Cerviño, AlejandroQueirós, A.González-Méijome, José Manuel20152015-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/33538engRodrigues, Patrícia; Lopes-Ferreira, Daniela; Catarino, Andreia; Cervino, Alejandro; Queirós, Antonio; González-Méijome, José Manuel. Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT, Journal of Modern Optics, 1, 1-8, 2015.0950-034010.1080/09500340.2014.995733info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:26:25ZPortal AgregadorONG
dc.title.none.fl_str_mv Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT
title Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT
spellingShingle Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT
Rodrigues, Patrícia
Optical coherence tomography
Manual layer segmentation
Repeatability
Corneal thickness
Epithelial thickness
Tear film thickness
Science & Technology
title_short Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT
title_full Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT
title_fullStr Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT
title_full_unstemmed Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT
title_sort Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT
author Rodrigues, Patrícia
author_facet Rodrigues, Patrícia
Ferreira, Daniela Lopes
Catarino, A.
Cerviño, Alejandro
Queirós, A.
González-Méijome, José Manuel
author_role author
author2 Ferreira, Daniela Lopes
Catarino, A.
Cerviño, Alejandro
Queirós, A.
González-Méijome, José Manuel
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Rodrigues, Patrícia
Ferreira, Daniela Lopes
Catarino, A.
Cerviño, Alejandro
Queirós, A.
González-Méijome, José Manuel
dc.subject.por.fl_str_mv Optical coherence tomography
Manual layer segmentation
Repeatability
Corneal thickness
Epithelial thickness
Tear film thickness
Science & Technology
topic Optical coherence tomography
Manual layer segmentation
Repeatability
Corneal thickness
Epithelial thickness
Tear film thickness
Science & Technology
description In this study, we aimed to evaluate the intra/inter-session and intra/inter-observer variability of manual segmentation of thickness of the pre-lens tear film, contact lens (CL), post-lens tear film, epithelium, bowman’s layer, stroma and the whole cornea and CLs with a flat and a steep fit, using a commercial high-resolution spectral domain optical coherence tomographer (OCT). Two different observers obtained three repeated measures in two separate sessions. A high correlation was found between the values obtained by the two different observers, except for the thinner layers, epithelium, and Bowman’s layer. Inter-observer analysis showed a high consistency in the measurements obtained by both observers (r 2 ≥ 0.80; p < 0.001) for the thicker layers: CL, stroma, and total cornea. Intra-observer analysis of measurements obtained by each observer within the same session displayed no statistically significant differences between the three repeated measures for both observers (p > 0.05). The present results suggest that manual segmentation of anterior segment OCT images in CL wearers provides acceptable levels of repeatability between observers and between different sessions for the thinner layers, while presenting a high level of repeatability for the thicker layers.
publishDate 2015
dc.date.none.fl_str_mv 2015
2015-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/33538
url http://hdl.handle.net/1822/33538
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Rodrigues, Patrícia; Lopes-Ferreira, Daniela; Catarino, Andreia; Cervino, Alejandro; Queirós, Antonio; González-Méijome, José Manuel. Reliability of manual segmentation of cornea, contact lens and tear film using a high-resolution OCT, Journal of Modern Optics, 1, 1-8, 2015.
0950-0340
10.1080/09500340.2014.995733
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Taylor and Francis
publisher.none.fl_str_mv Taylor and Francis
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1777303757937180672