Keratoconus and Visual Performance with Different Contact Lenses

Detalhes bibliográficos
Autor(a) principal: Marta, Ana
Data de Publicação: 2021
Outros Autores: Marques, Joao Heitor, Almeida, Daniel, José, Diana, Barbosa, Irene
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.16/2828
Resumo: Purpose: To analyze the visual performance in contact lens wearers with keratoconus. Methods: A retrospective study including contact lens (CL) wearers was performed. The current best-corrected visual acuity with contact lens (BCVA-CL) and with spectacles (BCVA-S) correction, contrast sensitivity (CS) (by Metrovision-MonPack3®), analysis of light scattering in the retina and vision break-up time (HD Analyzer®), and corneal tomography (Oculus Pentacam® HR) were evaluated. Results: This study included 96 eyes of 59 patients with Keratoconus. Rigid gas permeable contact lenses (RGPCL), hybrid contact lenses (HCL), and silicone hydrogel/hydrogel contact lenses (HGCL) were fitted in 67, 17, and 12 eyes, respectively. Dynamic objective scatter index (OSI) (p = 0.024), minimum OSI (p = 0.037) and maximum OSI (p = 0.040) were significantly better with RGPCL and worse with HGCL. Mean CS in photopic conditions was significantly worse with HGCL and better with HCL (p = 0.006), without differences in mesopic conditions (p = 0.121). RGPCL wearers showed a higher mean K (p = 0.020), and a lower corneal thickness at the thinnest point (p=0.011). Conclusion: Visual quality varied significantly with different types of CL. Although RGPCL was fitted in patients with worse Pentacam tomographic parameters, RGPCL was associated with a better dynamic visual quality.
id RCAP_f699082fb6da743fda046798cc78554a
oai_identifier_str oai:repositorio.chporto.pt:10400.16/2828
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Keratoconus and Visual Performance with Different Contact Lensescontact lenskeratoconusoptical qualityvisual performancePurpose: To analyze the visual performance in contact lens wearers with keratoconus. Methods: A retrospective study including contact lens (CL) wearers was performed. The current best-corrected visual acuity with contact lens (BCVA-CL) and with spectacles (BCVA-S) correction, contrast sensitivity (CS) (by Metrovision-MonPack3®), analysis of light scattering in the retina and vision break-up time (HD Analyzer®), and corneal tomography (Oculus Pentacam® HR) were evaluated. Results: This study included 96 eyes of 59 patients with Keratoconus. Rigid gas permeable contact lenses (RGPCL), hybrid contact lenses (HCL), and silicone hydrogel/hydrogel contact lenses (HGCL) were fitted in 67, 17, and 12 eyes, respectively. Dynamic objective scatter index (OSI) (p = 0.024), minimum OSI (p = 0.037) and maximum OSI (p = 0.040) were significantly better with RGPCL and worse with HGCL. Mean CS in photopic conditions was significantly worse with HGCL and better with HCL (p = 0.006), without differences in mesopic conditions (p = 0.121). RGPCL wearers showed a higher mean K (p = 0.020), and a lower corneal thickness at the thinnest point (p=0.011). Conclusion: Visual quality varied significantly with different types of CL. Although RGPCL was fitted in patients with worse Pentacam tomographic parameters, RGPCL was associated with a better dynamic visual quality.Dove Medical PressRepositório Científico do Centro Hospitalar Universitário de Santo AntónioMarta, AnaMarques, Joao HeitorAlmeida, DanielJosé, DianaBarbosa, Irene2023-10-23T08:22:25Z2021-122021-12-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.16/2828engMarta A, Marques JH, Almeida D, José D, Barbosa I. Keratoconus and Visual Performance with Different Contact Lenses. Clin Ophthalmol. 2021;15:4697-4705. doi:10.2147/OPTH.S3451541177-546710.2147/OPTH.S345154info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-10-26T05:19:13Zoai:repositorio.chporto.pt:10400.16/2828Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:39:38.175107Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Keratoconus and Visual Performance with Different Contact Lenses
title Keratoconus and Visual Performance with Different Contact Lenses
spellingShingle Keratoconus and Visual Performance with Different Contact Lenses
Marta, Ana
contact lens
keratoconus
optical quality
visual performance
title_short Keratoconus and Visual Performance with Different Contact Lenses
title_full Keratoconus and Visual Performance with Different Contact Lenses
title_fullStr Keratoconus and Visual Performance with Different Contact Lenses
title_full_unstemmed Keratoconus and Visual Performance with Different Contact Lenses
title_sort Keratoconus and Visual Performance with Different Contact Lenses
author Marta, Ana
author_facet Marta, Ana
Marques, Joao Heitor
Almeida, Daniel
José, Diana
Barbosa, Irene
author_role author
author2 Marques, Joao Heitor
Almeida, Daniel
José, Diana
Barbosa, Irene
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Repositório Científico do Centro Hospitalar Universitário de Santo António
dc.contributor.author.fl_str_mv Marta, Ana
Marques, Joao Heitor
Almeida, Daniel
José, Diana
Barbosa, Irene
dc.subject.por.fl_str_mv contact lens
keratoconus
optical quality
visual performance
topic contact lens
keratoconus
optical quality
visual performance
description Purpose: To analyze the visual performance in contact lens wearers with keratoconus. Methods: A retrospective study including contact lens (CL) wearers was performed. The current best-corrected visual acuity with contact lens (BCVA-CL) and with spectacles (BCVA-S) correction, contrast sensitivity (CS) (by Metrovision-MonPack3®), analysis of light scattering in the retina and vision break-up time (HD Analyzer®), and corneal tomography (Oculus Pentacam® HR) were evaluated. Results: This study included 96 eyes of 59 patients with Keratoconus. Rigid gas permeable contact lenses (RGPCL), hybrid contact lenses (HCL), and silicone hydrogel/hydrogel contact lenses (HGCL) were fitted in 67, 17, and 12 eyes, respectively. Dynamic objective scatter index (OSI) (p = 0.024), minimum OSI (p = 0.037) and maximum OSI (p = 0.040) were significantly better with RGPCL and worse with HGCL. Mean CS in photopic conditions was significantly worse with HGCL and better with HCL (p = 0.006), without differences in mesopic conditions (p = 0.121). RGPCL wearers showed a higher mean K (p = 0.020), and a lower corneal thickness at the thinnest point (p=0.011). Conclusion: Visual quality varied significantly with different types of CL. Although RGPCL was fitted in patients with worse Pentacam tomographic parameters, RGPCL was associated with a better dynamic visual quality.
publishDate 2021
dc.date.none.fl_str_mv 2021-12
2021-12-01T00:00:00Z
2023-10-23T08:22:25Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.16/2828
url http://hdl.handle.net/10400.16/2828
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Marta A, Marques JH, Almeida D, José D, Barbosa I. Keratoconus and Visual Performance with Different Contact Lenses. Clin Ophthalmol. 2021;15:4697-4705. doi:10.2147/OPTH.S345154
1177-5467
10.2147/OPTH.S345154
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Dove Medical Press
publisher.none.fl_str_mv Dove Medical Press
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799133657954254848