Optimization of Methodology for Determination of Inorganic Chromium Species in Sewage Sludge Samples by HPLC-ICP-MS/MS

Detalhes bibliográficos
Autor(a) principal: Barbosa,Érica S.
Data de Publicação: 2020
Outros Autores: Cacique,Ane P., Pinho,Gevany P. de, Silvério,Flaviano O.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532020001202491
Resumo: This study developed a methodology for extracting and speciating CrIII and CrVI in sewage sludge by high performance liquid chromatography, inductively coupled plasma tandem mass spectrometry (HPLC-ICP-MS/MS). The optimal procedure was solid-liquid extraction in a water bath with stirring at 50 °C for 16 h and 50 mmol L−1 ethylenediaminetetraacetic acid (EDTA) extraction phase at pH 9.5. In the validated method, the recovery in the fortification experiment was greater than 70% and the relative standard deviation was less than 7%. Speciation analyses showed that all CrVI was spontaneously reduced to CrIII in the sludge sample. The limits of detection and quantification were 0.060 and 0.20 µg L−1, respectively, and the analyses of CrIII by means of ICP-MS/MS were linear from 0.20 to 50 µg L−1. The extraction efficiency of Cr specie in this validated method improved from 4.09 to 53.3% compared to the EPA 1311 method. The methodology was successfully applied to quantify CrIII in a sludge sample with a lower concentration than that established by European legislation 80568/4225/91.
id SBQ-2_81ae08f97eb490585805a9fbc4c5018f
oai_identifier_str oai:scielo:S0103-50532020001202491
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Optimization of Methodology for Determination of Inorganic Chromium Species in Sewage Sludge Samples by HPLC-ICP-MS/MSsewage sludgechromiumextractionreductioninorganic chromium speciesThis study developed a methodology for extracting and speciating CrIII and CrVI in sewage sludge by high performance liquid chromatography, inductively coupled plasma tandem mass spectrometry (HPLC-ICP-MS/MS). The optimal procedure was solid-liquid extraction in a water bath with stirring at 50 °C for 16 h and 50 mmol L−1 ethylenediaminetetraacetic acid (EDTA) extraction phase at pH 9.5. In the validated method, the recovery in the fortification experiment was greater than 70% and the relative standard deviation was less than 7%. Speciation analyses showed that all CrVI was spontaneously reduced to CrIII in the sludge sample. The limits of detection and quantification were 0.060 and 0.20 µg L−1, respectively, and the analyses of CrIII by means of ICP-MS/MS were linear from 0.20 to 50 µg L−1. The extraction efficiency of Cr specie in this validated method improved from 4.09 to 53.3% compared to the EPA 1311 method. The methodology was successfully applied to quantify CrIII in a sludge sample with a lower concentration than that established by European legislation 80568/4225/91.Sociedade Brasileira de Química2020-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532020001202491Journal of the Brazilian Chemical Society v.31 n.12 2020reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0103-5053.20200124info:eu-repo/semantics/openAccessBarbosa,Érica S.Cacique,Ane P.Pinho,Gevany P. deSilvério,Flaviano O.eng2020-12-09T00:00:00Zoai:scielo:S0103-50532020001202491Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2020-12-09T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Optimization of Methodology for Determination of Inorganic Chromium Species in Sewage Sludge Samples by HPLC-ICP-MS/MS
title Optimization of Methodology for Determination of Inorganic Chromium Species in Sewage Sludge Samples by HPLC-ICP-MS/MS
spellingShingle Optimization of Methodology for Determination of Inorganic Chromium Species in Sewage Sludge Samples by HPLC-ICP-MS/MS
Barbosa,Érica S.
sewage sludge
chromium
extraction
reduction
inorganic chromium species
title_short Optimization of Methodology for Determination of Inorganic Chromium Species in Sewage Sludge Samples by HPLC-ICP-MS/MS
title_full Optimization of Methodology for Determination of Inorganic Chromium Species in Sewage Sludge Samples by HPLC-ICP-MS/MS
title_fullStr Optimization of Methodology for Determination of Inorganic Chromium Species in Sewage Sludge Samples by HPLC-ICP-MS/MS
title_full_unstemmed Optimization of Methodology for Determination of Inorganic Chromium Species in Sewage Sludge Samples by HPLC-ICP-MS/MS
title_sort Optimization of Methodology for Determination of Inorganic Chromium Species in Sewage Sludge Samples by HPLC-ICP-MS/MS
author Barbosa,Érica S.
author_facet Barbosa,Érica S.
Cacique,Ane P.
Pinho,Gevany P. de
Silvério,Flaviano O.
author_role author
author2 Cacique,Ane P.
Pinho,Gevany P. de
Silvério,Flaviano O.
author2_role author
author
author
dc.contributor.author.fl_str_mv Barbosa,Érica S.
Cacique,Ane P.
Pinho,Gevany P. de
Silvério,Flaviano O.
dc.subject.por.fl_str_mv sewage sludge
chromium
extraction
reduction
inorganic chromium species
topic sewage sludge
chromium
extraction
reduction
inorganic chromium species
description This study developed a methodology for extracting and speciating CrIII and CrVI in sewage sludge by high performance liquid chromatography, inductively coupled plasma tandem mass spectrometry (HPLC-ICP-MS/MS). The optimal procedure was solid-liquid extraction in a water bath with stirring at 50 °C for 16 h and 50 mmol L−1 ethylenediaminetetraacetic acid (EDTA) extraction phase at pH 9.5. In the validated method, the recovery in the fortification experiment was greater than 70% and the relative standard deviation was less than 7%. Speciation analyses showed that all CrVI was spontaneously reduced to CrIII in the sludge sample. The limits of detection and quantification were 0.060 and 0.20 µg L−1, respectively, and the analyses of CrIII by means of ICP-MS/MS were linear from 0.20 to 50 µg L−1. The extraction efficiency of Cr specie in this validated method improved from 4.09 to 53.3% compared to the EPA 1311 method. The methodology was successfully applied to quantify CrIII in a sludge sample with a lower concentration than that established by European legislation 80568/4225/91.
publishDate 2020
dc.date.none.fl_str_mv 2020-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532020001202491
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532020001202491
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.21577/0103-5053.20200124
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.31 n.12 2020
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318183535869952