Effects of PEEP on Hemodynamic Variables in Pigs Submitted to Volume-controlled Ventilation under Pneumoperitoneum associated to Cephalodeclive

Detalhes bibliográficos
Autor(a) principal: Ido, Cléber Kazuo [UNESP]
Data de Publicação: 2021
Outros Autores: Nunes, Newton [UNESP]
Tipo de documento: Artigo
Idioma: por
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.22456/1679-9216.113720
http://hdl.handle.net/11449/230217
Resumo: Background: Videolaparoscopic procedures have gained prominence due to their low invasiveness, causing less surgical trauma and better post-surgical recovery. However, the increase in intra-abdominal pressure due to the institution of pneumoperitoneum can alter the patient's homeostasis. Therefore, volume-controlled ventilation, associated with positive end-expiratory pressure (PEEP), improves arterial oxygenation and prevents pulmonary collapse, but it can lead to important hemodynamic changes. The aim of this study was to evaluate, comparatively, the effects of positive end expiratory-pressure (PEEP) on hemodynamic variables of pigs submitted to volume-controlled ventilation, during pneumoperitoneum and maintained in head-down tilt and determine which PEEP value promotes greater stability on hemodynamic variables. Materials, Methods & Results: Twenty-four pigs were used, between 55 and 65-day-old, weighing between 15 and 25 kg, randomly divided into 3 distinct groups differentiated by positive end-expiratory pressure: PEEP 0 (volume-controlled ventilation and PEEP of 0 cmH2O), PEEP 5 (volume-controlled ventilation and PEEP of 5 cmH2O) and PEEP 10 (volume-controlled ventilation and PEEP of 10 cmH2O). Volume-controlled ventilation was adjusted to 8 mL/kg of tidal volume and a respiratory rate of 25 movements per min. Anesthesia was maintained with continuous infusion of propofol (0.2 mg/kg/min) and midazolam (1 mg/kg/h). Pneumoperitoneum was performed with carbon dioxide (CO2), keeping the intra-abdominal pressure at 15 mmHg and the animals were positioned on a 30° head-down tilt. The evaluations of hemodynamic variables started 30 min after induction of anesthesia (M0), followed by measurements at 15-min intervals (from M15 to M90), completing a total of 7 evaluations. The variables of interest were collected over 90 min and submitted to analysis of variance followed by Tukey's post-hoc test, with P < 0.05. The PEEP 10 group had higher values of CVP and mCPP, while the PEEP 5 group, mPAP and PVR were higher. The PEEP 0 group, on the other hand, had higher means of CI. Regarding the moments, there were differences in HR, SAP, DAP, MAP, CO, IC and TPR. Discussion: According to the literature, important hemodynamic effects due to pneumoperitoneum are reported, which can be caused by the pressure used in abdominal insufflation, CO2 accumulation, duration of the surgical procedure, hydration status and patient positioning. Mechanical ventilation associated with PEEP can also cause an increase in intrathoracic pressure and, therefore, reduce cardiac output. Cardiovascular changes are proportional to the PEEP used. Central venous pressure (PVC) measure the patient's preload, and intrathoracic pressure can interfere with this parameter. The peak pressure values in the PEEP 10 group were higher than the other groups, demonstrating that the increase in intrathoracic pressure results in higher PVC values. Regarding PAPm and PCPm, these variables can be influenced according to the PEEP values and the patient's position. In relation to CI, the increase in PEEP may reflect on intrathoracic pressure, resulting in greater compression of the heart, with a consequent reduction in cardiac output and cardiac index. Therefore, it is concluded that the PEEP effects of 0 cmH2O and 5 cmH2O on hemodynamics are discrete, under the proposed conditions.
id UNSP_30d0972be8706b9ff07402b10e500c0f
oai_identifier_str oai:repositorio.unesp.br:11449/230217
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Effects of PEEP on Hemodynamic Variables in Pigs Submitted to Volume-controlled Ventilation under Pneumoperitoneum associated to CephalodecliveEfeitos da PEEP na ventilação controlada a volume sobre parâmetros hemodinâmicos em suínos submetidos ao pneumoperitônio associado ao cefalodecliveHead-down tiltMechanical ventilationPEEPSwineVCVBackground: Videolaparoscopic procedures have gained prominence due to their low invasiveness, causing less surgical trauma and better post-surgical recovery. However, the increase in intra-abdominal pressure due to the institution of pneumoperitoneum can alter the patient's homeostasis. Therefore, volume-controlled ventilation, associated with positive end-expiratory pressure (PEEP), improves arterial oxygenation and prevents pulmonary collapse, but it can lead to important hemodynamic changes. The aim of this study was to evaluate, comparatively, the effects of positive end expiratory-pressure (PEEP) on hemodynamic variables of pigs submitted to volume-controlled ventilation, during pneumoperitoneum and maintained in head-down tilt and determine which PEEP value promotes greater stability on hemodynamic variables. Materials, Methods & Results: Twenty-four pigs were used, between 55 and 65-day-old, weighing between 15 and 25 kg, randomly divided into 3 distinct groups differentiated by positive end-expiratory pressure: PEEP 0 (volume-controlled ventilation and PEEP of 0 cmH2O), PEEP 5 (volume-controlled ventilation and PEEP of 5 cmH2O) and PEEP 10 (volume-controlled ventilation and PEEP of 10 cmH2O). Volume-controlled ventilation was adjusted to 8 mL/kg of tidal volume and a respiratory rate of 25 movements per min. Anesthesia was maintained with continuous infusion of propofol (0.2 mg/kg/min) and midazolam (1 mg/kg/h). Pneumoperitoneum was performed with carbon dioxide (CO2), keeping the intra-abdominal pressure at 15 mmHg and the animals were positioned on a 30° head-down tilt. The evaluations of hemodynamic variables started 30 min after induction of anesthesia (M0), followed by measurements at 15-min intervals (from M15 to M90), completing a total of 7 evaluations. The variables of interest were collected over 90 min and submitted to analysis of variance followed by Tukey's post-hoc test, with P < 0.05. The PEEP 10 group had higher values of CVP and mCPP, while the PEEP 5 group, mPAP and PVR were higher. The PEEP 0 group, on the other hand, had higher means of CI. Regarding the moments, there were differences in HR, SAP, DAP, MAP, CO, IC and TPR. Discussion: According to the literature, important hemodynamic effects due to pneumoperitoneum are reported, which can be caused by the pressure used in abdominal insufflation, CO2 accumulation, duration of the surgical procedure, hydration status and patient positioning. Mechanical ventilation associated with PEEP can also cause an increase in intrathoracic pressure and, therefore, reduce cardiac output. Cardiovascular changes are proportional to the PEEP used. Central venous pressure (PVC) measure the patient's preload, and intrathoracic pressure can interfere with this parameter. The peak pressure values in the PEEP 10 group were higher than the other groups, demonstrating that the increase in intrathoracic pressure results in higher PVC values. Regarding PAPm and PCPm, these variables can be influenced according to the PEEP values and the patient's position. In relation to CI, the increase in PEEP may reflect on intrathoracic pressure, resulting in greater compression of the heart, with a consequent reduction in cardiac output and cardiac index. Therefore, it is concluded that the PEEP effects of 0 cmH2O and 5 cmH2O on hemodynamics are discrete, under the proposed conditions.Departamento de Clínica e Cirurgia Veterinária (DCCV) Faculdade de Ciências Agrárias e Veterinárias (FCAV) Unesp, Jaboticabal, SPDepartamento de Clínica e Cirurgia Veterinária (DCCV) Faculdade de Ciências Agrárias e Veterinárias (FCAV) Unesp, Jaboticabal, SPUniversidade Estadual Paulista (UNESP)Ido, Cléber Kazuo [UNESP]Nunes, Newton [UNESP]2022-04-29T08:38:36Z2022-04-29T08:38:36Z2021-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.22456/1679-9216.113720Acta Scientiae Veterinariae, v. 49.1679-92161678-0345http://hdl.handle.net/11449/23021710.22456/1679-9216.1137202-s2.0-85122835774Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPporActa Scientiae Veterinariaeinfo:eu-repo/semantics/openAccess2022-04-29T08:38:36Zoai:repositorio.unesp.br:11449/230217Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462022-04-29T08:38:36Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Effects of PEEP on Hemodynamic Variables in Pigs Submitted to Volume-controlled Ventilation under Pneumoperitoneum associated to Cephalodeclive
Efeitos da PEEP na ventilação controlada a volume sobre parâmetros hemodinâmicos em suínos submetidos ao pneumoperitônio associado ao cefalodeclive
title Effects of PEEP on Hemodynamic Variables in Pigs Submitted to Volume-controlled Ventilation under Pneumoperitoneum associated to Cephalodeclive
spellingShingle Effects of PEEP on Hemodynamic Variables in Pigs Submitted to Volume-controlled Ventilation under Pneumoperitoneum associated to Cephalodeclive
Ido, Cléber Kazuo [UNESP]
Head-down tilt
Mechanical ventilation
PEEP
Swine
VCV
title_short Effects of PEEP on Hemodynamic Variables in Pigs Submitted to Volume-controlled Ventilation under Pneumoperitoneum associated to Cephalodeclive
title_full Effects of PEEP on Hemodynamic Variables in Pigs Submitted to Volume-controlled Ventilation under Pneumoperitoneum associated to Cephalodeclive
title_fullStr Effects of PEEP on Hemodynamic Variables in Pigs Submitted to Volume-controlled Ventilation under Pneumoperitoneum associated to Cephalodeclive
title_full_unstemmed Effects of PEEP on Hemodynamic Variables in Pigs Submitted to Volume-controlled Ventilation under Pneumoperitoneum associated to Cephalodeclive
title_sort Effects of PEEP on Hemodynamic Variables in Pigs Submitted to Volume-controlled Ventilation under Pneumoperitoneum associated to Cephalodeclive
author Ido, Cléber Kazuo [UNESP]
author_facet Ido, Cléber Kazuo [UNESP]
Nunes, Newton [UNESP]
author_role author
author2 Nunes, Newton [UNESP]
author2_role author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (UNESP)
dc.contributor.author.fl_str_mv Ido, Cléber Kazuo [UNESP]
Nunes, Newton [UNESP]
dc.subject.por.fl_str_mv Head-down tilt
Mechanical ventilation
PEEP
Swine
VCV
topic Head-down tilt
Mechanical ventilation
PEEP
Swine
VCV
description Background: Videolaparoscopic procedures have gained prominence due to their low invasiveness, causing less surgical trauma and better post-surgical recovery. However, the increase in intra-abdominal pressure due to the institution of pneumoperitoneum can alter the patient's homeostasis. Therefore, volume-controlled ventilation, associated with positive end-expiratory pressure (PEEP), improves arterial oxygenation and prevents pulmonary collapse, but it can lead to important hemodynamic changes. The aim of this study was to evaluate, comparatively, the effects of positive end expiratory-pressure (PEEP) on hemodynamic variables of pigs submitted to volume-controlled ventilation, during pneumoperitoneum and maintained in head-down tilt and determine which PEEP value promotes greater stability on hemodynamic variables. Materials, Methods & Results: Twenty-four pigs were used, between 55 and 65-day-old, weighing between 15 and 25 kg, randomly divided into 3 distinct groups differentiated by positive end-expiratory pressure: PEEP 0 (volume-controlled ventilation and PEEP of 0 cmH2O), PEEP 5 (volume-controlled ventilation and PEEP of 5 cmH2O) and PEEP 10 (volume-controlled ventilation and PEEP of 10 cmH2O). Volume-controlled ventilation was adjusted to 8 mL/kg of tidal volume and a respiratory rate of 25 movements per min. Anesthesia was maintained with continuous infusion of propofol (0.2 mg/kg/min) and midazolam (1 mg/kg/h). Pneumoperitoneum was performed with carbon dioxide (CO2), keeping the intra-abdominal pressure at 15 mmHg and the animals were positioned on a 30° head-down tilt. The evaluations of hemodynamic variables started 30 min after induction of anesthesia (M0), followed by measurements at 15-min intervals (from M15 to M90), completing a total of 7 evaluations. The variables of interest were collected over 90 min and submitted to analysis of variance followed by Tukey's post-hoc test, with P < 0.05. The PEEP 10 group had higher values of CVP and mCPP, while the PEEP 5 group, mPAP and PVR were higher. The PEEP 0 group, on the other hand, had higher means of CI. Regarding the moments, there were differences in HR, SAP, DAP, MAP, CO, IC and TPR. Discussion: According to the literature, important hemodynamic effects due to pneumoperitoneum are reported, which can be caused by the pressure used in abdominal insufflation, CO2 accumulation, duration of the surgical procedure, hydration status and patient positioning. Mechanical ventilation associated with PEEP can also cause an increase in intrathoracic pressure and, therefore, reduce cardiac output. Cardiovascular changes are proportional to the PEEP used. Central venous pressure (PVC) measure the patient's preload, and intrathoracic pressure can interfere with this parameter. The peak pressure values in the PEEP 10 group were higher than the other groups, demonstrating that the increase in intrathoracic pressure results in higher PVC values. Regarding PAPm and PCPm, these variables can be influenced according to the PEEP values and the patient's position. In relation to CI, the increase in PEEP may reflect on intrathoracic pressure, resulting in greater compression of the heart, with a consequent reduction in cardiac output and cardiac index. Therefore, it is concluded that the PEEP effects of 0 cmH2O and 5 cmH2O on hemodynamics are discrete, under the proposed conditions.
publishDate 2021
dc.date.none.fl_str_mv 2021-01-01
2022-04-29T08:38:36Z
2022-04-29T08:38:36Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.22456/1679-9216.113720
Acta Scientiae Veterinariae, v. 49.
1679-9216
1678-0345
http://hdl.handle.net/11449/230217
10.22456/1679-9216.113720
2-s2.0-85122835774
url http://dx.doi.org/10.22456/1679-9216.113720
http://hdl.handle.net/11449/230217
identifier_str_mv Acta Scientiae Veterinariae, v. 49.
1679-9216
1678-0345
10.22456/1679-9216.113720
2-s2.0-85122835774
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv Acta Scientiae Veterinariae
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1792961460948697088