Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures

Detalhes bibliográficos
Autor(a) principal: Suedam, Valdey
Data de Publicação: 2016
Outros Autores: Moretti Neto, Rafael Tobias, Capello Sousa, Edson Antonio [UNESP], Rubo, Jose Henrique
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1590/1678-775720150297
http://hdl.handle.net/11449/161459
Resumo: Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. Objectives: To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. Material and Methods: A U-shaped polyurethane model simulating the mandibular bone containing two implants (circle divide 3.75 mm) was used. Six groups were formed according to the alloy's framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the nnesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. Results: Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p<0.05) between the groups. Pearson correlation test (p<0.05) was applied showing positive correlations between the increase of the cantilever arm and the deformation of the peri-implant area. Conclusions: This report demonstrated the CoCr alloy shows larger compression values compared to the PdAg alloy for the same distances of cantilever. The point of load application influences the deformation on the peri-implant area, increasing in accordance with the increase of the lever arm.
id UNSP_33bd44b26bb30cb24d7a97b5b3cba05a
oai_identifier_str oai:repositorio.unesp.br:11449/161459
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial denturesImplant-supported dental prosthesisDental implantsIn vitro techniquesMechanical stressBecause many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. Objectives: To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. Material and Methods: A U-shaped polyurethane model simulating the mandibular bone containing two implants (circle divide 3.75 mm) was used. Six groups were formed according to the alloy's framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the nnesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. Results: Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p<0.05) between the groups. Pearson correlation test (p<0.05) was applied showing positive correlations between the increase of the cantilever arm and the deformation of the peri-implant area. Conclusions: This report demonstrated the CoCr alloy shows larger compression values compared to the PdAg alloy for the same distances of cantilever. The point of load application influences the deformation on the peri-implant area, increasing in accordance with the increase of the lever arm.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Univ Sagrado Coracao, Fac Odontol, Bauru, SP, BrazilUniv Fed Alfenas, Fac Odontol, Dept Clin & Cirurgia, Alfenas, MG, BrazilUniv Estadual Paulista, Fac Engn, Dept Engn Mecan, Bauru, SP, BrazilUniv Sao Paulo, Fac Odontol Bauru, Dept Protese, Bauru, SP, BrazilUniv Estadual Paulista, Fac Engn, Dept Engn Mecan, Bauru, SP, BrazilFAPESP: 99/01402-6FAPESP: 05/56182-3Univ Sao Paulo Fac Odontologia BauruUniv Sagrado CoracaoUniv Fed AlfenasUniversidade Estadual Paulista (Unesp)Universidade de São Paulo (USP)Suedam, ValdeyMoretti Neto, Rafael TobiasCapello Sousa, Edson Antonio [UNESP]Rubo, Jose Henrique2018-11-26T16:32:49Z2018-11-26T16:32:49Z2016-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article114-120application/pdfhttp://dx.doi.org/10.1590/1678-775720150297Journal Of Applied Oral Science. Bauru-sp: Univ Sao Paulo Fac Odontologia Bauru, v. 24, n. 2, p. 114-120, 2016.1678-7757http://hdl.handle.net/11449/16145910.1590/1678-775720150297S1678-77572016000200114WOS:000375085400002S1678-77572016000200114.pdfWeb of Sciencereponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal Of Applied Oral Science0,645info:eu-repo/semantics/openAccess2024-01-14T06:20:54Zoai:repositorio.unesp.br:11449/161459Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-01-14T06:20:54Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
spellingShingle Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
Suedam, Valdey
Implant-supported dental prosthesis
Dental implants
In vitro techniques
Mechanical stress
title_short Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title_full Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title_fullStr Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title_full_unstemmed Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title_sort Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
author Suedam, Valdey
author_facet Suedam, Valdey
Moretti Neto, Rafael Tobias
Capello Sousa, Edson Antonio [UNESP]
Rubo, Jose Henrique
author_role author
author2 Moretti Neto, Rafael Tobias
Capello Sousa, Edson Antonio [UNESP]
Rubo, Jose Henrique
author2_role author
author
author
dc.contributor.none.fl_str_mv Univ Sagrado Coracao
Univ Fed Alfenas
Universidade Estadual Paulista (Unesp)
Universidade de São Paulo (USP)
dc.contributor.author.fl_str_mv Suedam, Valdey
Moretti Neto, Rafael Tobias
Capello Sousa, Edson Antonio [UNESP]
Rubo, Jose Henrique
dc.subject.por.fl_str_mv Implant-supported dental prosthesis
Dental implants
In vitro techniques
Mechanical stress
topic Implant-supported dental prosthesis
Dental implants
In vitro techniques
Mechanical stress
description Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. Objectives: To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. Material and Methods: A U-shaped polyurethane model simulating the mandibular bone containing two implants (circle divide 3.75 mm) was used. Six groups were formed according to the alloy's framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the nnesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. Results: Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p<0.05) between the groups. Pearson correlation test (p<0.05) was applied showing positive correlations between the increase of the cantilever arm and the deformation of the peri-implant area. Conclusions: This report demonstrated the CoCr alloy shows larger compression values compared to the PdAg alloy for the same distances of cantilever. The point of load application influences the deformation on the peri-implant area, increasing in accordance with the increase of the lever arm.
publishDate 2016
dc.date.none.fl_str_mv 2016-03-01
2018-11-26T16:32:49Z
2018-11-26T16:32:49Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1590/1678-775720150297
Journal Of Applied Oral Science. Bauru-sp: Univ Sao Paulo Fac Odontologia Bauru, v. 24, n. 2, p. 114-120, 2016.
1678-7757
http://hdl.handle.net/11449/161459
10.1590/1678-775720150297
S1678-77572016000200114
WOS:000375085400002
S1678-77572016000200114.pdf
url http://dx.doi.org/10.1590/1678-775720150297
http://hdl.handle.net/11449/161459
identifier_str_mv Journal Of Applied Oral Science. Bauru-sp: Univ Sao Paulo Fac Odontologia Bauru, v. 24, n. 2, p. 114-120, 2016.
1678-7757
10.1590/1678-775720150297
S1678-77572016000200114
WOS:000375085400002
S1678-77572016000200114.pdf
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal Of Applied Oral Science
0,645
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 114-120
application/pdf
dc.publisher.none.fl_str_mv Univ Sao Paulo Fac Odontologia Bauru
publisher.none.fl_str_mv Univ Sao Paulo Fac Odontologia Bauru
dc.source.none.fl_str_mv Web of Science
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1799965613368541184