Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures

Detalhes bibliográficos
Autor(a) principal: SUEDAM, Valdey
Data de Publicação: 2016
Outros Autores: MORETTI NETO, Rafael Tobias, SOUSA, Edson Antonio Capello, RUBO, José Henrique
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of applied oral science (Online)
Texto Completo: https://www.revistas.usp.br/jaos/article/view/114785
Resumo: Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. Objectives To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. Material and Methods A U-shaped polyurethane model simulating the mandibular bone containing two implants (Ø 3.75 mm) was used. Six groups were formed according to the alloy’s framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the mesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. Results Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p
id USP-17_7737ca476be97c1c78ac6828b45b4297
oai_identifier_str oai:revistas.usp.br:article/114785
network_acronym_str USP-17
network_name_str Journal of applied oral science (Online)
repository_id_str
spelling Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. Objectives To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. Material and Methods A U-shaped polyurethane model simulating the mandibular bone containing two implants (Ø 3.75 mm) was used. Six groups were formed according to the alloy’s framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the mesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. Results Two-way ANOVA and Tukey statistical tests were applied showing significant differences (pUniversidade de São Paulo. Faculdade de Odontologia de Bauru2016-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/jaos/article/view/11478510.1590/1678-775720150297Journal of Applied Oral Science; Vol. 24 No. 2 (2016); 114-120Journal of Applied Oral Science; Vol. 24 Núm. 2 (2016); 114-120Journal of Applied Oral Science; v. 24 n. 2 (2016); 114-1201678-77651678-7757reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USPenghttps://www.revistas.usp.br/jaos/article/view/114785/112519Copyright (c) 2016 Journal of Applied Oral Scienceinfo:eu-repo/semantics/openAccessSUEDAM, ValdeyMORETTI NETO, Rafael TobiasSOUSA, Edson Antonio CapelloRUBO, José Henrique2016-04-26T19:50:05Zoai:revistas.usp.br:article/114785Revistahttp://www.scielo.br/jaosPUBhttps://www.revistas.usp.br/jaos/oai||jaos@usp.br1678-77651678-7757opendoar:2016-04-26T19:50:05Journal of applied oral science (Online) - Universidade de São Paulo (USP)false
dc.title.none.fl_str_mv Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
spellingShingle Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
SUEDAM, Valdey
title_short Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title_full Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title_fullStr Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title_full_unstemmed Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
title_sort Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures
author SUEDAM, Valdey
author_facet SUEDAM, Valdey
MORETTI NETO, Rafael Tobias
SOUSA, Edson Antonio Capello
RUBO, José Henrique
author_role author
author2 MORETTI NETO, Rafael Tobias
SOUSA, Edson Antonio Capello
RUBO, José Henrique
author2_role author
author
author
dc.contributor.author.fl_str_mv SUEDAM, Valdey
MORETTI NETO, Rafael Tobias
SOUSA, Edson Antonio Capello
RUBO, José Henrique
description Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. Objectives To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. Material and Methods A U-shaped polyurethane model simulating the mandibular bone containing two implants (Ø 3.75 mm) was used. Six groups were formed according to the alloy’s framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the mesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. Results Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p
publishDate 2016
dc.date.none.fl_str_mv 2016-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/jaos/article/view/114785
10.1590/1678-775720150297
url https://www.revistas.usp.br/jaos/article/view/114785
identifier_str_mv 10.1590/1678-775720150297
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/jaos/article/view/114785/112519
dc.rights.driver.fl_str_mv Copyright (c) 2016 Journal of Applied Oral Science
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2016 Journal of Applied Oral Science
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
publisher.none.fl_str_mv Universidade de São Paulo. Faculdade de Odontologia de Bauru
dc.source.none.fl_str_mv Journal of Applied Oral Science; Vol. 24 No. 2 (2016); 114-120
Journal of Applied Oral Science; Vol. 24 Núm. 2 (2016); 114-120
Journal of Applied Oral Science; v. 24 n. 2 (2016); 114-120
1678-7765
1678-7757
reponame:Journal of applied oral science (Online)
instname:Universidade de São Paulo (USP)
instacron:USP
instname_str Universidade de São Paulo (USP)
instacron_str USP
institution USP
reponame_str Journal of applied oral science (Online)
collection Journal of applied oral science (Online)
repository.name.fl_str_mv Journal of applied oral science (Online) - Universidade de São Paulo (USP)
repository.mail.fl_str_mv ||jaos@usp.br
_version_ 1800221679607087104