Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Anais da Academia Brasileira de Ciências (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652016000300791 |
Resumo: | A modified simplex algorithm was used to optimize a system of preconcentration for cadmium determination in samples of sediments, cigarettes and food using flame atomic absorption spectrometry. The preconcentration system is based on the sorption of cadmium in a minicolumn packed with Amberlite XAD-2 resin functionalized with 3,4-dihydroxybenzoic acid (DHB). The optimized variables were pH and sampling flow rate and the optimum conditions found for these variables were, respectively 8.7 and 8.8 mL min-1. The developed system showed a preconcentration factor of 15.3, detection limit of 0.49 µg L-1, quantification limit of 1.65 µg L-1 and precision expressed as relative standard deviation (% RSD, n=10) of 5.9. The accuracy of the method was checked by analysis of estuary sediment certified reference material (NIST 1646-1). The cadmium concentrations found in sediment samples ranged from 1.73 and 1.90 µg g-1. In cigarette samples the results were 0.085 and 0.193 µg g-1, and in food samples (coriander and lettuce) the concentrations found of this metal were, respectively, 0.33 and 0.12 µg g-1. |
id |
ABC-1_6dac9added1d3a53e910dfc496c253e7 |
---|---|
oai_identifier_str |
oai:scielo:S0001-37652016000300791 |
network_acronym_str |
ABC-1 |
network_name_str |
Anais da Academia Brasileira de Ciências (Online) |
repository_id_str |
|
spelling |
Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettessimplex optimizationpreconcentrationcadmiumsedimentscigarettesfoodA modified simplex algorithm was used to optimize a system of preconcentration for cadmium determination in samples of sediments, cigarettes and food using flame atomic absorption spectrometry. The preconcentration system is based on the sorption of cadmium in a minicolumn packed with Amberlite XAD-2 resin functionalized with 3,4-dihydroxybenzoic acid (DHB). The optimized variables were pH and sampling flow rate and the optimum conditions found for these variables were, respectively 8.7 and 8.8 mL min-1. The developed system showed a preconcentration factor of 15.3, detection limit of 0.49 µg L-1, quantification limit of 1.65 µg L-1 and precision expressed as relative standard deviation (% RSD, n=10) of 5.9. The accuracy of the method was checked by analysis of estuary sediment certified reference material (NIST 1646-1). The cadmium concentrations found in sediment samples ranged from 1.73 and 1.90 µg g-1. In cigarette samples the results were 0.085 and 0.193 µg g-1, and in food samples (coriander and lettuce) the concentrations found of this metal were, respectively, 0.33 and 0.12 µg g-1.Academia Brasileira de Ciências2016-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652016000300791Anais da Academia Brasileira de Ciências v.88 n.2 2016reponame:Anais da Academia Brasileira de Ciências (Online)instname:Academia Brasileira de Ciências (ABC)instacron:ABC10.1590/0001-3765201620150209info:eu-repo/semantics/openAccessSANTOS,QUEILA O.MORENO,ISLANIASANTOS,LEANDRO DOSSANTOS,ALDENOR G.SOUZA,VALDINEI S.BEZERRA,MARCOS A.eng2016-06-30T00:00:00Zoai:scielo:S0001-37652016000300791Revistahttp://www.scielo.br/aabchttps://old.scielo.br/oai/scielo-oai.php||aabc@abc.org.br1678-26900001-3765opendoar:2016-06-30T00:00Anais da Academia Brasileira de Ciências (Online) - Academia Brasileira de Ciências (ABC)false |
dc.title.none.fl_str_mv |
Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes |
title |
Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes |
spellingShingle |
Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes SANTOS,QUEILA O. simplex optimization preconcentration cadmium sediments cigarettes food |
title_short |
Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes |
title_full |
Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes |
title_fullStr |
Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes |
title_full_unstemmed |
Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes |
title_sort |
Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes |
author |
SANTOS,QUEILA O. |
author_facet |
SANTOS,QUEILA O. MORENO,ISLANIA SANTOS,LEANDRO DOS SANTOS,ALDENOR G. SOUZA,VALDINEI S. BEZERRA,MARCOS A. |
author_role |
author |
author2 |
MORENO,ISLANIA SANTOS,LEANDRO DOS SANTOS,ALDENOR G. SOUZA,VALDINEI S. BEZERRA,MARCOS A. |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
SANTOS,QUEILA O. MORENO,ISLANIA SANTOS,LEANDRO DOS SANTOS,ALDENOR G. SOUZA,VALDINEI S. BEZERRA,MARCOS A. |
dc.subject.por.fl_str_mv |
simplex optimization preconcentration cadmium sediments cigarettes food |
topic |
simplex optimization preconcentration cadmium sediments cigarettes food |
description |
A modified simplex algorithm was used to optimize a system of preconcentration for cadmium determination in samples of sediments, cigarettes and food using flame atomic absorption spectrometry. The preconcentration system is based on the sorption of cadmium in a minicolumn packed with Amberlite XAD-2 resin functionalized with 3,4-dihydroxybenzoic acid (DHB). The optimized variables were pH and sampling flow rate and the optimum conditions found for these variables were, respectively 8.7 and 8.8 mL min-1. The developed system showed a preconcentration factor of 15.3, detection limit of 0.49 µg L-1, quantification limit of 1.65 µg L-1 and precision expressed as relative standard deviation (% RSD, n=10) of 5.9. The accuracy of the method was checked by analysis of estuary sediment certified reference material (NIST 1646-1). The cadmium concentrations found in sediment samples ranged from 1.73 and 1.90 µg g-1. In cigarette samples the results were 0.085 and 0.193 µg g-1, and in food samples (coriander and lettuce) the concentrations found of this metal were, respectively, 0.33 and 0.12 µg g-1. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652016000300791 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652016000300791 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0001-3765201620150209 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Academia Brasileira de Ciências |
publisher.none.fl_str_mv |
Academia Brasileira de Ciências |
dc.source.none.fl_str_mv |
Anais da Academia Brasileira de Ciências v.88 n.2 2016 reponame:Anais da Academia Brasileira de Ciências (Online) instname:Academia Brasileira de Ciências (ABC) instacron:ABC |
instname_str |
Academia Brasileira de Ciências (ABC) |
instacron_str |
ABC |
institution |
ABC |
reponame_str |
Anais da Academia Brasileira de Ciências (Online) |
collection |
Anais da Academia Brasileira de Ciências (Online) |
repository.name.fl_str_mv |
Anais da Academia Brasileira de Ciências (Online) - Academia Brasileira de Ciências (ABC) |
repository.mail.fl_str_mv |
||aabc@abc.org.br |
_version_ |
1754302862813298688 |