Resumo: A modified simplex algorithm was used to optimize a system of preconcentration for cadmium determination in samples of sediments, cigarettes and food using flame atomic absorption spectrometry. The preconcentration system is based on the sorption of cadmium in a minicolumn packed with Amberlite XAD-2 resin functionalized with 3,4-dihydroxybenzoic acid (DHB). The optimized variables were pH and sampling flow rate and the optimum conditions found for these variables were, respectively 8.7 and 8.8 mL min-1. The developed system showed a preconcentration factor of 15.3, detection limit of 0.49 µg L-1, quantification limit of 1.65 µg L-1 and precision expressed as relative standard deviation (% RSD, n=10) of 5.9. The accuracy of the method was checked by analysis of estuary sediment certified reference material (NIST 1646-1). The cadmium concentrations found in sediment samples ranged from 1.73 and 1.90 µg g-1. In cigarette samples the results were 0.085 and 0.193 µg g-1, and in food samples (coriander and lettuce) the concentrations found of this metal were, respectively, 0.33 and 0.12 µg g-1.
id ABC-1_6dac9added1d3a53e910dfc496c253e7
oai_identifier_str oai:scielo:S0001-37652016000300791
network_acronym_str ABC-1
network_name_str Anais da Academia Brasileira de Ciências (Online)
repository_id_str
spelling Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettessimplex optimizationpreconcentrationcadmiumsedimentscigarettesfoodA modified simplex algorithm was used to optimize a system of preconcentration for cadmium determination in samples of sediments, cigarettes and food using flame atomic absorption spectrometry. The preconcentration system is based on the sorption of cadmium in a minicolumn packed with Amberlite XAD-2 resin functionalized with 3,4-dihydroxybenzoic acid (DHB). The optimized variables were pH and sampling flow rate and the optimum conditions found for these variables were, respectively 8.7 and 8.8 mL min-1. The developed system showed a preconcentration factor of 15.3, detection limit of 0.49 µg L-1, quantification limit of 1.65 µg L-1 and precision expressed as relative standard deviation (% RSD, n=10) of 5.9. The accuracy of the method was checked by analysis of estuary sediment certified reference material (NIST 1646-1). The cadmium concentrations found in sediment samples ranged from 1.73 and 1.90 µg g-1. In cigarette samples the results were 0.085 and 0.193 µg g-1, and in food samples (coriander and lettuce) the concentrations found of this metal were, respectively, 0.33 and 0.12 µg g-1.Academia Brasileira de Ciências2016-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652016000300791Anais da Academia Brasileira de Ciências v.88 n.2 2016reponame:Anais da Academia Brasileira de Ciências (Online)instname:Academia Brasileira de Ciências (ABC)instacron:ABC10.1590/0001-3765201620150209info:eu-repo/semantics/openAccessSANTOS,QUEILA O.MORENO,ISLANIASANTOS,LEANDRO DOSSANTOS,ALDENOR G.SOUZA,VALDINEI S.BEZERRA,MARCOS A.eng2016-06-30T00:00:00Zoai:scielo:S0001-37652016000300791Revistahttp://www.scielo.br/aabchttps://old.scielo.br/oai/scielo-oai.php||aabc@abc.org.br1678-26900001-3765opendoar:2016-06-30T00:00Anais da Academia Brasileira de Ciências (Online) - Academia Brasileira de Ciências (ABC)false
dc.title.none.fl_str_mv Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
title Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
spellingShingle Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
SANTOS,QUEILA O.
simplex optimization
preconcentration
cadmium
sediments
cigarettes
food
title_short Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
title_full Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
title_fullStr Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
title_full_unstemmed Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
title_sort Application of modified simplex on the development of a preconcentration system for cadmium determination in sediments, food and cigarettes
author SANTOS,QUEILA O.
author_facet SANTOS,QUEILA O.
MORENO,ISLANIA
SANTOS,LEANDRO DOS
SANTOS,ALDENOR G.
SOUZA,VALDINEI S.
BEZERRA,MARCOS A.
author_role author
author2 MORENO,ISLANIA
SANTOS,LEANDRO DOS
SANTOS,ALDENOR G.
SOUZA,VALDINEI S.
BEZERRA,MARCOS A.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv SANTOS,QUEILA O.
MORENO,ISLANIA
SANTOS,LEANDRO DOS
SANTOS,ALDENOR G.
SOUZA,VALDINEI S.
BEZERRA,MARCOS A.
dc.subject.por.fl_str_mv simplex optimization
preconcentration
cadmium
sediments
cigarettes
food
topic simplex optimization
preconcentration
cadmium
sediments
cigarettes
food
description A modified simplex algorithm was used to optimize a system of preconcentration for cadmium determination in samples of sediments, cigarettes and food using flame atomic absorption spectrometry. The preconcentration system is based on the sorption of cadmium in a minicolumn packed with Amberlite XAD-2 resin functionalized with 3,4-dihydroxybenzoic acid (DHB). The optimized variables were pH and sampling flow rate and the optimum conditions found for these variables were, respectively 8.7 and 8.8 mL min-1. The developed system showed a preconcentration factor of 15.3, detection limit of 0.49 µg L-1, quantification limit of 1.65 µg L-1 and precision expressed as relative standard deviation (% RSD, n=10) of 5.9. The accuracy of the method was checked by analysis of estuary sediment certified reference material (NIST 1646-1). The cadmium concentrations found in sediment samples ranged from 1.73 and 1.90 µg g-1. In cigarette samples the results were 0.085 and 0.193 µg g-1, and in food samples (coriander and lettuce) the concentrations found of this metal were, respectively, 0.33 and 0.12 µg g-1.
publishDate 2016
dc.date.none.fl_str_mv 2016-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652016000300791
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652016000300791
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0001-3765201620150209
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Academia Brasileira de Ciências
publisher.none.fl_str_mv Academia Brasileira de Ciências
dc.source.none.fl_str_mv Anais da Academia Brasileira de Ciências v.88 n.2 2016
reponame:Anais da Academia Brasileira de Ciências (Online)
instname:Academia Brasileira de Ciências (ABC)
instacron:ABC
instname_str Academia Brasileira de Ciências (ABC)
instacron_str ABC
institution ABC
reponame_str Anais da Academia Brasileira de Ciências (Online)
collection Anais da Academia Brasileira de Ciências (Online)
repository.name.fl_str_mv Anais da Academia Brasileira de Ciências (Online) - Academia Brasileira de Ciências (ABC)
repository.mail.fl_str_mv ||aabc@abc.org.br
_version_ 1754302862813298688