Stoichiometry-based estimates of ferric iron in calcic, sodic-calcic and sodic amphiboles: a comparison of various methods
Autor(a) principal: | |
---|---|
Data de Publicação: | 2005 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Anais da Academia Brasileira de Ciências (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652005000300012 |
Resumo: | An important drawback of the electron microprobe is its inability to quantify Fe3+/Fe2+ ratios in routine work. Although these ratios can be calculated, there is no unique criterion that can be applied to all amphiboles. Using a large data set of calcic, sodic-calcic, and sodic amphibole analysis from A-type granites and syenites from southern Brazil, weassess the choices made by the method of Schumacher (1997, Canadian Mineralogist, 35: 238-246), which uses the average between selected maximum and minimum estimates. Maximum estimates selected most frequently are: 13 cations excluding Ca, Na, and K (13eCNK - 66%); sum of Si and Al equal to 8 (8SiAl - 17%); 15 cations excluding K (15eK - 8%). These selections are appropriate based on crystallochemical considerations. Minimum estimates are mostly all iron as Fe2+ (all Fe2 - 71%), and are clearly inadequate. Hence, maximum estimates should better approximate the actual values. To test this, complete analyses were selected from the literature, and calculated and measured values were compared. 13eCNK and maximum estimates are precise and accurate (concordance correlation coefficient- r c <FONT FACE=Symbol>»</FONT> 0.85). As expected, averages yield poor estimates (r c = 0.56). We recommend, thus, that maximum estimates be used for calcic, sodic-calcic, and sodic amphiboles. |
id |
ABC-1_b9e6ddaa8fd1d7e5be158b04e630e7a7 |
---|---|
oai_identifier_str |
oai:scielo:S0001-37652005000300012 |
network_acronym_str |
ABC-1 |
network_name_str |
Anais da Academia Brasileira de Ciências (Online) |
repository_id_str |
|
spelling |
Stoichiometry-based estimates of ferric iron in calcic, sodic-calcic and sodic amphiboles: a comparison of various methodsamphibolesstoichiometryferric ironEPMAAn important drawback of the electron microprobe is its inability to quantify Fe3+/Fe2+ ratios in routine work. Although these ratios can be calculated, there is no unique criterion that can be applied to all amphiboles. Using a large data set of calcic, sodic-calcic, and sodic amphibole analysis from A-type granites and syenites from southern Brazil, weassess the choices made by the method of Schumacher (1997, Canadian Mineralogist, 35: 238-246), which uses the average between selected maximum and minimum estimates. Maximum estimates selected most frequently are: 13 cations excluding Ca, Na, and K (13eCNK - 66%); sum of Si and Al equal to 8 (8SiAl - 17%); 15 cations excluding K (15eK - 8%). These selections are appropriate based on crystallochemical considerations. Minimum estimates are mostly all iron as Fe2+ (all Fe2 - 71%), and are clearly inadequate. Hence, maximum estimates should better approximate the actual values. To test this, complete analyses were selected from the literature, and calculated and measured values were compared. 13eCNK and maximum estimates are precise and accurate (concordance correlation coefficient- r c <FONT FACE=Symbol>»</FONT> 0.85). As expected, averages yield poor estimates (r c = 0.56). We recommend, thus, that maximum estimates be used for calcic, sodic-calcic, and sodic amphiboles.Academia Brasileira de Ciências2005-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652005000300012Anais da Academia Brasileira de Ciências v.77 n.3 2005reponame:Anais da Academia Brasileira de Ciências (Online)instname:Academia Brasileira de Ciências (ABC)instacron:ABC10.1590/S0001-37652005000300012info:eu-repo/semantics/openAccessGualda,Guilherme A.R.Vlach,Silvio R.F.eng2005-08-24T00:00:00Zoai:scielo:S0001-37652005000300012Revistahttp://www.scielo.br/aabchttps://old.scielo.br/oai/scielo-oai.php||aabc@abc.org.br1678-26900001-3765opendoar:2005-08-24T00:00Anais da Academia Brasileira de Ciências (Online) - Academia Brasileira de Ciências (ABC)false |
dc.title.none.fl_str_mv |
Stoichiometry-based estimates of ferric iron in calcic, sodic-calcic and sodic amphiboles: a comparison of various methods |
title |
Stoichiometry-based estimates of ferric iron in calcic, sodic-calcic and sodic amphiboles: a comparison of various methods |
spellingShingle |
Stoichiometry-based estimates of ferric iron in calcic, sodic-calcic and sodic amphiboles: a comparison of various methods Gualda,Guilherme A.R. amphiboles stoichiometry ferric iron EPMA |
title_short |
Stoichiometry-based estimates of ferric iron in calcic, sodic-calcic and sodic amphiboles: a comparison of various methods |
title_full |
Stoichiometry-based estimates of ferric iron in calcic, sodic-calcic and sodic amphiboles: a comparison of various methods |
title_fullStr |
Stoichiometry-based estimates of ferric iron in calcic, sodic-calcic and sodic amphiboles: a comparison of various methods |
title_full_unstemmed |
Stoichiometry-based estimates of ferric iron in calcic, sodic-calcic and sodic amphiboles: a comparison of various methods |
title_sort |
Stoichiometry-based estimates of ferric iron in calcic, sodic-calcic and sodic amphiboles: a comparison of various methods |
author |
Gualda,Guilherme A.R. |
author_facet |
Gualda,Guilherme A.R. Vlach,Silvio R.F. |
author_role |
author |
author2 |
Vlach,Silvio R.F. |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Gualda,Guilherme A.R. Vlach,Silvio R.F. |
dc.subject.por.fl_str_mv |
amphiboles stoichiometry ferric iron EPMA |
topic |
amphiboles stoichiometry ferric iron EPMA |
description |
An important drawback of the electron microprobe is its inability to quantify Fe3+/Fe2+ ratios in routine work. Although these ratios can be calculated, there is no unique criterion that can be applied to all amphiboles. Using a large data set of calcic, sodic-calcic, and sodic amphibole analysis from A-type granites and syenites from southern Brazil, weassess the choices made by the method of Schumacher (1997, Canadian Mineralogist, 35: 238-246), which uses the average between selected maximum and minimum estimates. Maximum estimates selected most frequently are: 13 cations excluding Ca, Na, and K (13eCNK - 66%); sum of Si and Al equal to 8 (8SiAl - 17%); 15 cations excluding K (15eK - 8%). These selections are appropriate based on crystallochemical considerations. Minimum estimates are mostly all iron as Fe2+ (all Fe2 - 71%), and are clearly inadequate. Hence, maximum estimates should better approximate the actual values. To test this, complete analyses were selected from the literature, and calculated and measured values were compared. 13eCNK and maximum estimates are precise and accurate (concordance correlation coefficient- r c <FONT FACE=Symbol>»</FONT> 0.85). As expected, averages yield poor estimates (r c = 0.56). We recommend, thus, that maximum estimates be used for calcic, sodic-calcic, and sodic amphiboles. |
publishDate |
2005 |
dc.date.none.fl_str_mv |
2005-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652005000300012 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652005000300012 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0001-37652005000300012 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Academia Brasileira de Ciências |
publisher.none.fl_str_mv |
Academia Brasileira de Ciências |
dc.source.none.fl_str_mv |
Anais da Academia Brasileira de Ciências v.77 n.3 2005 reponame:Anais da Academia Brasileira de Ciências (Online) instname:Academia Brasileira de Ciências (ABC) instacron:ABC |
instname_str |
Academia Brasileira de Ciências (ABC) |
instacron_str |
ABC |
institution |
ABC |
reponame_str |
Anais da Academia Brasileira de Ciências (Online) |
collection |
Anais da Academia Brasileira de Ciências (Online) |
repository.name.fl_str_mv |
Anais da Academia Brasileira de Ciências (Online) - Academia Brasileira de Ciências (ABC) |
repository.mail.fl_str_mv |
||aabc@abc.org.br |
_version_ |
1754302856457879552 |