Damage diagram of blast test results for determining reinforced concrete slab response for varying scaled distance, concrete strength and reinforcement ratio

Detalhes bibliográficos
Autor(a) principal: MENDONÇA,FAUSTO B.
Data de Publicação: 2021
Outros Autores: URGESSA,GIRUM S., ALMEIDA,LUIZ E.N., ROCCO,JOSÉ A.F.F.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Anais da Academia Brasileira de Ciências (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652021000101801
Resumo: Abstract Dynamic loads continue to draw the interest of structural engineers. The sources of these loads can be earthquakes, blast effects or transportation loads from railroads or highways. Especially for blast loads, terrorist attacks or military actions have caused many loses of lives and damages in several buildings. The verification of structural behavior is necessary to help designers to plan structures that support these loads and reduce damages. Although computer simulation with, specific software, have helped these designers, full-scale tests can provide valuable information about the real response of the structure. This paper presents damage diagram from ten full-scale field tests using approximately 2.70 kg of non-confined plastic bonded explosive against reinforced concrete slabs with different scaled distance, reinforcement ratio and concrete strength. The damage diagram is expected to be a help tool for designers to understand the effects of blast loads on slabs.
id ABC-1_bf58255a1893b95143fced7ce3a1f681
oai_identifier_str oai:scielo:S0001-37652021000101801
network_acronym_str ABC-1
network_name_str Anais da Academia Brasileira de Ciências (Online)
repository_id_str
spelling Damage diagram of blast test results for determining reinforced concrete slab response for varying scaled distance, concrete strength and reinforcement ratioBlast field testdynamic loadreinforced concretenon-confined plastic explosiveAbstract Dynamic loads continue to draw the interest of structural engineers. The sources of these loads can be earthquakes, blast effects or transportation loads from railroads or highways. Especially for blast loads, terrorist attacks or military actions have caused many loses of lives and damages in several buildings. The verification of structural behavior is necessary to help designers to plan structures that support these loads and reduce damages. Although computer simulation with, specific software, have helped these designers, full-scale tests can provide valuable information about the real response of the structure. This paper presents damage diagram from ten full-scale field tests using approximately 2.70 kg of non-confined plastic bonded explosive against reinforced concrete slabs with different scaled distance, reinforcement ratio and concrete strength. The damage diagram is expected to be a help tool for designers to understand the effects of blast loads on slabs.Academia Brasileira de Ciências2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652021000101801Anais da Academia Brasileira de Ciências v.93 n.1 2021reponame:Anais da Academia Brasileira de Ciências (Online)instname:Academia Brasileira de Ciências (ABC)instacron:ABC10.1590/0001-3765202120200511info:eu-repo/semantics/openAccessMENDONÇA,FAUSTO B.URGESSA,GIRUM S.ALMEIDA,LUIZ E.N.ROCCO,JOSÉ A.F.F.eng2021-03-15T00:00:00Zoai:scielo:S0001-37652021000101801Revistahttp://www.scielo.br/aabchttps://old.scielo.br/oai/scielo-oai.php||aabc@abc.org.br1678-26900001-3765opendoar:2021-03-15T00:00Anais da Academia Brasileira de Ciências (Online) - Academia Brasileira de Ciências (ABC)false
dc.title.none.fl_str_mv Damage diagram of blast test results for determining reinforced concrete slab response for varying scaled distance, concrete strength and reinforcement ratio
title Damage diagram of blast test results for determining reinforced concrete slab response for varying scaled distance, concrete strength and reinforcement ratio
spellingShingle Damage diagram of blast test results for determining reinforced concrete slab response for varying scaled distance, concrete strength and reinforcement ratio
MENDONÇA,FAUSTO B.
Blast field test
dynamic load
reinforced concrete
non-confined plastic explosive
title_short Damage diagram of blast test results for determining reinforced concrete slab response for varying scaled distance, concrete strength and reinforcement ratio
title_full Damage diagram of blast test results for determining reinforced concrete slab response for varying scaled distance, concrete strength and reinforcement ratio
title_fullStr Damage diagram of blast test results for determining reinforced concrete slab response for varying scaled distance, concrete strength and reinforcement ratio
title_full_unstemmed Damage diagram of blast test results for determining reinforced concrete slab response for varying scaled distance, concrete strength and reinforcement ratio
title_sort Damage diagram of blast test results for determining reinforced concrete slab response for varying scaled distance, concrete strength and reinforcement ratio
author MENDONÇA,FAUSTO B.
author_facet MENDONÇA,FAUSTO B.
URGESSA,GIRUM S.
ALMEIDA,LUIZ E.N.
ROCCO,JOSÉ A.F.F.
author_role author
author2 URGESSA,GIRUM S.
ALMEIDA,LUIZ E.N.
ROCCO,JOSÉ A.F.F.
author2_role author
author
author
dc.contributor.author.fl_str_mv MENDONÇA,FAUSTO B.
URGESSA,GIRUM S.
ALMEIDA,LUIZ E.N.
ROCCO,JOSÉ A.F.F.
dc.subject.por.fl_str_mv Blast field test
dynamic load
reinforced concrete
non-confined plastic explosive
topic Blast field test
dynamic load
reinforced concrete
non-confined plastic explosive
description Abstract Dynamic loads continue to draw the interest of structural engineers. The sources of these loads can be earthquakes, blast effects or transportation loads from railroads or highways. Especially for blast loads, terrorist attacks or military actions have caused many loses of lives and damages in several buildings. The verification of structural behavior is necessary to help designers to plan structures that support these loads and reduce damages. Although computer simulation with, specific software, have helped these designers, full-scale tests can provide valuable information about the real response of the structure. This paper presents damage diagram from ten full-scale field tests using approximately 2.70 kg of non-confined plastic bonded explosive against reinforced concrete slabs with different scaled distance, reinforcement ratio and concrete strength. The damage diagram is expected to be a help tool for designers to understand the effects of blast loads on slabs.
publishDate 2021
dc.date.none.fl_str_mv 2021-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652021000101801
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652021000101801
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0001-3765202120200511
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Academia Brasileira de Ciências
publisher.none.fl_str_mv Academia Brasileira de Ciências
dc.source.none.fl_str_mv Anais da Academia Brasileira de Ciências v.93 n.1 2021
reponame:Anais da Academia Brasileira de Ciências (Online)
instname:Academia Brasileira de Ciências (ABC)
instacron:ABC
instname_str Academia Brasileira de Ciências (ABC)
instacron_str ABC
institution ABC
reponame_str Anais da Academia Brasileira de Ciências (Online)
collection Anais da Academia Brasileira de Ciências (Online)
repository.name.fl_str_mv Anais da Academia Brasileira de Ciências (Online) - Academia Brasileira de Ciências (ABC)
repository.mail.fl_str_mv ||aabc@abc.org.br
_version_ 1754302869763260416