Temperature pull-down of a retrofitted wine refrigerator cabinet cooled by a caloric system emulator

Detalhes bibliográficos
Autor(a) principal: CALOMENO,RICARDO S.
Data de Publicação: 2022
Outros Autores: DUTRA,SERGIO L., SÁ,NATÁLIA M. DE, PEIXER,GUILHERME F., LOZANO,JAIME A., BARBOSA JR.,JADER R.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Anais da Academia Brasileira de Ciências (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652022000601702
Resumo: Abstract The present study analyzes the time-dependent thermal behavior of a retrofitted wine refrigerator cabinet operated by a caloric system emulator. The presence of a full load of wine bottles enabled the assessment of the thermal stratification inside the cabinet. Further experimental tests have been performed to quantify the overall thermal conductance of the cabinet walls and the thermal conductance of the glass door. A detailed mathematical model was developed to predict the temperature pull down in the refrigerated compartment, considering the interaction between the cabinet air and the wine bottles. In addition to the air and bottle temperatures, a good agreement (lower than 15% relative error) was observed for the cooling capacity. The numerical simulations revealed that the cabinet door was responsible for approximately 60% of the thermal load (even though it corresponded to approximately 20% of the cabinet external area).
id ABC-1_e0411dba85f11a02bc61fb28ee7f165a
oai_identifier_str oai:scielo:S0001-37652022000601702
network_acronym_str ABC-1
network_name_str Anais da Academia Brasileira de Ciências (Online)
repository_id_str
spelling Temperature pull-down of a retrofitted wine refrigerator cabinet cooled by a caloric system emulatorCaloric coolingheat exchangersmathematical modelingrefrigerator cabinetwine coolerAbstract The present study analyzes the time-dependent thermal behavior of a retrofitted wine refrigerator cabinet operated by a caloric system emulator. The presence of a full load of wine bottles enabled the assessment of the thermal stratification inside the cabinet. Further experimental tests have been performed to quantify the overall thermal conductance of the cabinet walls and the thermal conductance of the glass door. A detailed mathematical model was developed to predict the temperature pull down in the refrigerated compartment, considering the interaction between the cabinet air and the wine bottles. In addition to the air and bottle temperatures, a good agreement (lower than 15% relative error) was observed for the cooling capacity. The numerical simulations revealed that the cabinet door was responsible for approximately 60% of the thermal load (even though it corresponded to approximately 20% of the cabinet external area).Academia Brasileira de Ciências2022-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652022000601702Anais da Academia Brasileira de Ciências v.94 n.4 2022reponame:Anais da Academia Brasileira de Ciências (Online)instname:Academia Brasileira de Ciências (ABC)instacron:ABC10.1590/0001-3765202220201510info:eu-repo/semantics/openAccessCALOMENO,RICARDO S.DUTRA,SERGIO L.SÁ,NATÁLIA M. DEPEIXER,GUILHERME F.LOZANO,JAIME A.BARBOSA JR.,JADER R.eng2022-10-13T00:00:00Zoai:scielo:S0001-37652022000601702Revistahttp://www.scielo.br/aabchttps://old.scielo.br/oai/scielo-oai.php||aabc@abc.org.br1678-26900001-3765opendoar:2022-10-13T00:00Anais da Academia Brasileira de Ciências (Online) - Academia Brasileira de Ciências (ABC)false
dc.title.none.fl_str_mv Temperature pull-down of a retrofitted wine refrigerator cabinet cooled by a caloric system emulator
title Temperature pull-down of a retrofitted wine refrigerator cabinet cooled by a caloric system emulator
spellingShingle Temperature pull-down of a retrofitted wine refrigerator cabinet cooled by a caloric system emulator
CALOMENO,RICARDO S.
Caloric cooling
heat exchangers
mathematical modeling
refrigerator cabinet
wine cooler
title_short Temperature pull-down of a retrofitted wine refrigerator cabinet cooled by a caloric system emulator
title_full Temperature pull-down of a retrofitted wine refrigerator cabinet cooled by a caloric system emulator
title_fullStr Temperature pull-down of a retrofitted wine refrigerator cabinet cooled by a caloric system emulator
title_full_unstemmed Temperature pull-down of a retrofitted wine refrigerator cabinet cooled by a caloric system emulator
title_sort Temperature pull-down of a retrofitted wine refrigerator cabinet cooled by a caloric system emulator
author CALOMENO,RICARDO S.
author_facet CALOMENO,RICARDO S.
DUTRA,SERGIO L.
SÁ,NATÁLIA M. DE
PEIXER,GUILHERME F.
LOZANO,JAIME A.
BARBOSA JR.,JADER R.
author_role author
author2 DUTRA,SERGIO L.
SÁ,NATÁLIA M. DE
PEIXER,GUILHERME F.
LOZANO,JAIME A.
BARBOSA JR.,JADER R.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv CALOMENO,RICARDO S.
DUTRA,SERGIO L.
SÁ,NATÁLIA M. DE
PEIXER,GUILHERME F.
LOZANO,JAIME A.
BARBOSA JR.,JADER R.
dc.subject.por.fl_str_mv Caloric cooling
heat exchangers
mathematical modeling
refrigerator cabinet
wine cooler
topic Caloric cooling
heat exchangers
mathematical modeling
refrigerator cabinet
wine cooler
description Abstract The present study analyzes the time-dependent thermal behavior of a retrofitted wine refrigerator cabinet operated by a caloric system emulator. The presence of a full load of wine bottles enabled the assessment of the thermal stratification inside the cabinet. Further experimental tests have been performed to quantify the overall thermal conductance of the cabinet walls and the thermal conductance of the glass door. A detailed mathematical model was developed to predict the temperature pull down in the refrigerated compartment, considering the interaction between the cabinet air and the wine bottles. In addition to the air and bottle temperatures, a good agreement (lower than 15% relative error) was observed for the cooling capacity. The numerical simulations revealed that the cabinet door was responsible for approximately 60% of the thermal load (even though it corresponded to approximately 20% of the cabinet external area).
publishDate 2022
dc.date.none.fl_str_mv 2022-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652022000601702
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652022000601702
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0001-3765202220201510
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Academia Brasileira de Ciências
publisher.none.fl_str_mv Academia Brasileira de Ciências
dc.source.none.fl_str_mv Anais da Academia Brasileira de Ciências v.94 n.4 2022
reponame:Anais da Academia Brasileira de Ciências (Online)
instname:Academia Brasileira de Ciências (ABC)
instacron:ABC
instname_str Academia Brasileira de Ciências (ABC)
instacron_str ABC
institution ABC
reponame_str Anais da Academia Brasileira de Ciências (Online)
collection Anais da Academia Brasileira de Ciências (Online)
repository.name.fl_str_mv Anais da Academia Brasileira de Ciências (Online) - Academia Brasileira de Ciências (ABC)
repository.mail.fl_str_mv ||aabc@abc.org.br
_version_ 1754302872555618304