Stiffening Effect of Bolt-On Transducers on Strain Measurements

Detalhes bibliográficos
Autor(a) principal: Borri-Brunetto,Mauro
Data de Publicação: 2016
Outros Autores: Alessio,Marco, Barbero,Monica, Barpi,Fabrizio, Biagi,Valerio De, Pallara,Oronzo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Latin American journal of solids and structures (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-78252016000300536
Resumo: Abstract The strain of a structural element is often measured indirectly by determining the strain of a transducer that is supposed to follow the deformation of the element perfectly, and with negligible interaction, around the mounting point. However, this assumption is not always true, and depends on the stiffness of the transducer relative to the local stiffness of the piece to which it is attached. This paper deals with the problem of evaluating the influence that a relatively rigid transducer (the HBM SLB-700A was chosen as an example) has on the strain field, studied from both the theoretical and the experimental points of view. The findings of the research have shown that, in order to interpret the measurements obtained from this kind of instruments correctly, the perturbation induced on the strain field cannot be disregarded. A corrective factor, obtained numerically by means of the FEM and discussed in the paper, can be used as a first approximation to evaluate the true strain, stress and forces in common structural steel elements.
id ABCM-1_80988710ffddf12b67553ea114b62055
oai_identifier_str oai:scielo:S1679-78252016000300536
network_acronym_str ABCM-1
network_name_str Latin American journal of solids and structures (Online)
repository_id_str
spelling Stiffening Effect of Bolt-On Transducers on Strain MeasurementsElastic half-spacefinite element analysismeasurement errorssize effectsstrain transducersAbstract The strain of a structural element is often measured indirectly by determining the strain of a transducer that is supposed to follow the deformation of the element perfectly, and with negligible interaction, around the mounting point. However, this assumption is not always true, and depends on the stiffness of the transducer relative to the local stiffness of the piece to which it is attached. This paper deals with the problem of evaluating the influence that a relatively rigid transducer (the HBM SLB-700A was chosen as an example) has on the strain field, studied from both the theoretical and the experimental points of view. The findings of the research have shown that, in order to interpret the measurements obtained from this kind of instruments correctly, the perturbation induced on the strain field cannot be disregarded. A corrective factor, obtained numerically by means of the FEM and discussed in the paper, can be used as a first approximation to evaluate the true strain, stress and forces in common structural steel elements.Associação Brasileira de Ciências Mecânicas2016-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-78252016000300536Latin American Journal of Solids and Structures v.13 n.3 2016reponame:Latin American journal of solids and structures (Online)instname:Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)instacron:ABCM10.1590/1679-78252109info:eu-repo/semantics/openAccessBorri-Brunetto,MauroAlessio,MarcoBarbero,MonicaBarpi,FabrizioBiagi,Valerio DePallara,Oronzoeng2016-04-06T00:00:00Zoai:scielo:S1679-78252016000300536Revistahttp://www.scielo.br/scielo.php?script=sci_serial&pid=1679-7825&lng=pt&nrm=isohttps://old.scielo.br/oai/scielo-oai.phpabcm@abcm.org.br||maralves@usp.br1679-78251679-7817opendoar:2016-04-06T00:00Latin American journal of solids and structures (Online) - Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)false
dc.title.none.fl_str_mv Stiffening Effect of Bolt-On Transducers on Strain Measurements
title Stiffening Effect of Bolt-On Transducers on Strain Measurements
spellingShingle Stiffening Effect of Bolt-On Transducers on Strain Measurements
Borri-Brunetto,Mauro
Elastic half-space
finite element analysis
measurement errors
size effects
strain transducers
title_short Stiffening Effect of Bolt-On Transducers on Strain Measurements
title_full Stiffening Effect of Bolt-On Transducers on Strain Measurements
title_fullStr Stiffening Effect of Bolt-On Transducers on Strain Measurements
title_full_unstemmed Stiffening Effect of Bolt-On Transducers on Strain Measurements
title_sort Stiffening Effect of Bolt-On Transducers on Strain Measurements
author Borri-Brunetto,Mauro
author_facet Borri-Brunetto,Mauro
Alessio,Marco
Barbero,Monica
Barpi,Fabrizio
Biagi,Valerio De
Pallara,Oronzo
author_role author
author2 Alessio,Marco
Barbero,Monica
Barpi,Fabrizio
Biagi,Valerio De
Pallara,Oronzo
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Borri-Brunetto,Mauro
Alessio,Marco
Barbero,Monica
Barpi,Fabrizio
Biagi,Valerio De
Pallara,Oronzo
dc.subject.por.fl_str_mv Elastic half-space
finite element analysis
measurement errors
size effects
strain transducers
topic Elastic half-space
finite element analysis
measurement errors
size effects
strain transducers
description Abstract The strain of a structural element is often measured indirectly by determining the strain of a transducer that is supposed to follow the deformation of the element perfectly, and with negligible interaction, around the mounting point. However, this assumption is not always true, and depends on the stiffness of the transducer relative to the local stiffness of the piece to which it is attached. This paper deals with the problem of evaluating the influence that a relatively rigid transducer (the HBM SLB-700A was chosen as an example) has on the strain field, studied from both the theoretical and the experimental points of view. The findings of the research have shown that, in order to interpret the measurements obtained from this kind of instruments correctly, the perturbation induced on the strain field cannot be disregarded. A corrective factor, obtained numerically by means of the FEM and discussed in the paper, can be used as a first approximation to evaluate the true strain, stress and forces in common structural steel elements.
publishDate 2016
dc.date.none.fl_str_mv 2016-03-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-78252016000300536
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-78252016000300536
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1679-78252109
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Ciências Mecânicas
publisher.none.fl_str_mv Associação Brasileira de Ciências Mecânicas
dc.source.none.fl_str_mv Latin American Journal of Solids and Structures v.13 n.3 2016
reponame:Latin American journal of solids and structures (Online)
instname:Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)
instacron:ABCM
instname_str Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)
instacron_str ABCM
institution ABCM
reponame_str Latin American journal of solids and structures (Online)
collection Latin American journal of solids and structures (Online)
repository.name.fl_str_mv Latin American journal of solids and structures (Online) - Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)
repository.mail.fl_str_mv abcm@abcm.org.br||maralves@usp.br
_version_ 1754302888397504512