Stiffening Effect of Bolt-On Transducers on Strain Measurements
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Latin American journal of solids and structures (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-78252016000300536 |
Resumo: | Abstract The strain of a structural element is often measured indirectly by determining the strain of a transducer that is supposed to follow the deformation of the element perfectly, and with negligible interaction, around the mounting point. However, this assumption is not always true, and depends on the stiffness of the transducer relative to the local stiffness of the piece to which it is attached. This paper deals with the problem of evaluating the influence that a relatively rigid transducer (the HBM SLB-700A was chosen as an example) has on the strain field, studied from both the theoretical and the experimental points of view. The findings of the research have shown that, in order to interpret the measurements obtained from this kind of instruments correctly, the perturbation induced on the strain field cannot be disregarded. A corrective factor, obtained numerically by means of the FEM and discussed in the paper, can be used as a first approximation to evaluate the true strain, stress and forces in common structural steel elements. |
id |
ABCM-1_80988710ffddf12b67553ea114b62055 |
---|---|
oai_identifier_str |
oai:scielo:S1679-78252016000300536 |
network_acronym_str |
ABCM-1 |
network_name_str |
Latin American journal of solids and structures (Online) |
repository_id_str |
|
spelling |
Stiffening Effect of Bolt-On Transducers on Strain MeasurementsElastic half-spacefinite element analysismeasurement errorssize effectsstrain transducersAbstract The strain of a structural element is often measured indirectly by determining the strain of a transducer that is supposed to follow the deformation of the element perfectly, and with negligible interaction, around the mounting point. However, this assumption is not always true, and depends on the stiffness of the transducer relative to the local stiffness of the piece to which it is attached. This paper deals with the problem of evaluating the influence that a relatively rigid transducer (the HBM SLB-700A was chosen as an example) has on the strain field, studied from both the theoretical and the experimental points of view. The findings of the research have shown that, in order to interpret the measurements obtained from this kind of instruments correctly, the perturbation induced on the strain field cannot be disregarded. A corrective factor, obtained numerically by means of the FEM and discussed in the paper, can be used as a first approximation to evaluate the true strain, stress and forces in common structural steel elements.Associação Brasileira de Ciências Mecânicas2016-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-78252016000300536Latin American Journal of Solids and Structures v.13 n.3 2016reponame:Latin American journal of solids and structures (Online)instname:Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)instacron:ABCM10.1590/1679-78252109info:eu-repo/semantics/openAccessBorri-Brunetto,MauroAlessio,MarcoBarbero,MonicaBarpi,FabrizioBiagi,Valerio DePallara,Oronzoeng2016-04-06T00:00:00Zoai:scielo:S1679-78252016000300536Revistahttp://www.scielo.br/scielo.php?script=sci_serial&pid=1679-7825&lng=pt&nrm=isohttps://old.scielo.br/oai/scielo-oai.phpabcm@abcm.org.br||maralves@usp.br1679-78251679-7817opendoar:2016-04-06T00:00Latin American journal of solids and structures (Online) - Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)false |
dc.title.none.fl_str_mv |
Stiffening Effect of Bolt-On Transducers on Strain Measurements |
title |
Stiffening Effect of Bolt-On Transducers on Strain Measurements |
spellingShingle |
Stiffening Effect of Bolt-On Transducers on Strain Measurements Borri-Brunetto,Mauro Elastic half-space finite element analysis measurement errors size effects strain transducers |
title_short |
Stiffening Effect of Bolt-On Transducers on Strain Measurements |
title_full |
Stiffening Effect of Bolt-On Transducers on Strain Measurements |
title_fullStr |
Stiffening Effect of Bolt-On Transducers on Strain Measurements |
title_full_unstemmed |
Stiffening Effect of Bolt-On Transducers on Strain Measurements |
title_sort |
Stiffening Effect of Bolt-On Transducers on Strain Measurements |
author |
Borri-Brunetto,Mauro |
author_facet |
Borri-Brunetto,Mauro Alessio,Marco Barbero,Monica Barpi,Fabrizio Biagi,Valerio De Pallara,Oronzo |
author_role |
author |
author2 |
Alessio,Marco Barbero,Monica Barpi,Fabrizio Biagi,Valerio De Pallara,Oronzo |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Borri-Brunetto,Mauro Alessio,Marco Barbero,Monica Barpi,Fabrizio Biagi,Valerio De Pallara,Oronzo |
dc.subject.por.fl_str_mv |
Elastic half-space finite element analysis measurement errors size effects strain transducers |
topic |
Elastic half-space finite element analysis measurement errors size effects strain transducers |
description |
Abstract The strain of a structural element is often measured indirectly by determining the strain of a transducer that is supposed to follow the deformation of the element perfectly, and with negligible interaction, around the mounting point. However, this assumption is not always true, and depends on the stiffness of the transducer relative to the local stiffness of the piece to which it is attached. This paper deals with the problem of evaluating the influence that a relatively rigid transducer (the HBM SLB-700A was chosen as an example) has on the strain field, studied from both the theoretical and the experimental points of view. The findings of the research have shown that, in order to interpret the measurements obtained from this kind of instruments correctly, the perturbation induced on the strain field cannot be disregarded. A corrective factor, obtained numerically by means of the FEM and discussed in the paper, can be used as a first approximation to evaluate the true strain, stress and forces in common structural steel elements. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-03-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-78252016000300536 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-78252016000300536 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1679-78252109 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Ciências Mecânicas |
publisher.none.fl_str_mv |
Associação Brasileira de Ciências Mecânicas |
dc.source.none.fl_str_mv |
Latin American Journal of Solids and Structures v.13 n.3 2016 reponame:Latin American journal of solids and structures (Online) instname:Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM) instacron:ABCM |
instname_str |
Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM) |
instacron_str |
ABCM |
institution |
ABCM |
reponame_str |
Latin American journal of solids and structures (Online) |
collection |
Latin American journal of solids and structures (Online) |
repository.name.fl_str_mv |
Latin American journal of solids and structures (Online) - Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM) |
repository.mail.fl_str_mv |
abcm@abcm.org.br||maralves@usp.br |
_version_ |
1754302888397504512 |