An experimental investigation of new bent V-shaped shear connector

Detalhes bibliográficos
Autor(a) principal: Al-kroom,Hussein
Data de Publicação: 2021
Outros Autores: Thneibat,Mujahed, Alghrir,Yassin, Schmid,Volker
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Latin American journal of solids and structures (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-78252021000500502
Resumo: Abstract This paper investigates the behavior of a new form of V-shaped shear connector. The assessment of the proposed connector’s performance is conducted through an experimental work of fourteen push-out tests. The results show that the developed V-shaped shear connector is able to transfer higher shear load than the conventional shear connectors. In addition, its behavior is considered as ductile. Geometrical parameters of the connector are studied to observe their influence on its behavior. The experimental outcomes show that changing the length, width, and thickness of the connector significantly affects its ultimate strength while the connector's ductile behavior is preserved. Furthermore, the work proves that neither creating holes nor adding transverse reinforcement to the connector has significant effect on shear resistance and that the uplift-displacement of the connector is improved. A comprehensive comparison between the proposed shear connector and commonly used shear connectors is executed. Based on the experimental results, an empirical equation is suggested to predict the load capacity of the connector.
id ABCM-1_fc22d286b2385bbaa6c25a515a76dbf0
oai_identifier_str oai:scielo:S1679-78252021000500502
network_acronym_str ABCM-1
network_name_str Latin American journal of solids and structures (Online)
repository_id_str
spelling An experimental investigation of new bent V-shaped shear connectorShear connectorV-shaped shear connectorReinforced concreteSteel-concrete composite structuresAbstract This paper investigates the behavior of a new form of V-shaped shear connector. The assessment of the proposed connector’s performance is conducted through an experimental work of fourteen push-out tests. The results show that the developed V-shaped shear connector is able to transfer higher shear load than the conventional shear connectors. In addition, its behavior is considered as ductile. Geometrical parameters of the connector are studied to observe their influence on its behavior. The experimental outcomes show that changing the length, width, and thickness of the connector significantly affects its ultimate strength while the connector's ductile behavior is preserved. Furthermore, the work proves that neither creating holes nor adding transverse reinforcement to the connector has significant effect on shear resistance and that the uplift-displacement of the connector is improved. A comprehensive comparison between the proposed shear connector and commonly used shear connectors is executed. Based on the experimental results, an empirical equation is suggested to predict the load capacity of the connector.Associação Brasileira de Ciências Mecânicas2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-78252021000500502Latin American Journal of Solids and Structures v.18 n.5 2021reponame:Latin American journal of solids and structures (Online)instname:Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)instacron:ABCM10.1590/1679-78256438info:eu-repo/semantics/openAccessAl-kroom,HusseinThneibat,MujahedAlghrir,YassinSchmid,Volkereng2021-06-16T00:00:00Zoai:scielo:S1679-78252021000500502Revistahttp://www.scielo.br/scielo.php?script=sci_serial&pid=1679-7825&lng=pt&nrm=isohttps://old.scielo.br/oai/scielo-oai.phpabcm@abcm.org.br||maralves@usp.br1679-78251679-7817opendoar:2021-06-16T00:00Latin American journal of solids and structures (Online) - Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)false
dc.title.none.fl_str_mv An experimental investigation of new bent V-shaped shear connector
title An experimental investigation of new bent V-shaped shear connector
spellingShingle An experimental investigation of new bent V-shaped shear connector
Al-kroom,Hussein
Shear connector
V-shaped shear connector
Reinforced concrete
Steel-concrete composite structures
title_short An experimental investigation of new bent V-shaped shear connector
title_full An experimental investigation of new bent V-shaped shear connector
title_fullStr An experimental investigation of new bent V-shaped shear connector
title_full_unstemmed An experimental investigation of new bent V-shaped shear connector
title_sort An experimental investigation of new bent V-shaped shear connector
author Al-kroom,Hussein
author_facet Al-kroom,Hussein
Thneibat,Mujahed
Alghrir,Yassin
Schmid,Volker
author_role author
author2 Thneibat,Mujahed
Alghrir,Yassin
Schmid,Volker
author2_role author
author
author
dc.contributor.author.fl_str_mv Al-kroom,Hussein
Thneibat,Mujahed
Alghrir,Yassin
Schmid,Volker
dc.subject.por.fl_str_mv Shear connector
V-shaped shear connector
Reinforced concrete
Steel-concrete composite structures
topic Shear connector
V-shaped shear connector
Reinforced concrete
Steel-concrete composite structures
description Abstract This paper investigates the behavior of a new form of V-shaped shear connector. The assessment of the proposed connector’s performance is conducted through an experimental work of fourteen push-out tests. The results show that the developed V-shaped shear connector is able to transfer higher shear load than the conventional shear connectors. In addition, its behavior is considered as ductile. Geometrical parameters of the connector are studied to observe their influence on its behavior. The experimental outcomes show that changing the length, width, and thickness of the connector significantly affects its ultimate strength while the connector's ductile behavior is preserved. Furthermore, the work proves that neither creating holes nor adding transverse reinforcement to the connector has significant effect on shear resistance and that the uplift-displacement of the connector is improved. A comprehensive comparison between the proposed shear connector and commonly used shear connectors is executed. Based on the experimental results, an empirical equation is suggested to predict the load capacity of the connector.
publishDate 2021
dc.date.none.fl_str_mv 2021-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-78252021000500502
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-78252021000500502
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1679-78256438
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Ciências Mecânicas
publisher.none.fl_str_mv Associação Brasileira de Ciências Mecânicas
dc.source.none.fl_str_mv Latin American Journal of Solids and Structures v.18 n.5 2021
reponame:Latin American journal of solids and structures (Online)
instname:Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)
instacron:ABCM
instname_str Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)
instacron_str ABCM
institution ABCM
reponame_str Latin American journal of solids and structures (Online)
collection Latin American journal of solids and structures (Online)
repository.name.fl_str_mv Latin American journal of solids and structures (Online) - Associação Brasileira de Engenharia e Ciências Mecânicas (ABCM)
repository.mail.fl_str_mv abcm@abcm.org.br||maralves@usp.br
_version_ 1754302890790354944