Is endobronchial ultrasound-guided transbronchial needle aspiration with a stylet necessary for lymph node screening in lung cancer patients?

Detalhes bibliográficos
Autor(a) principal: Xu,Y.
Data de Publicação: 2017
Outros Autores: Lin,J., Jin,Y., Wu,X., Zheng,H., Feng,J.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Medical and Biological Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2017001000606
Resumo: During endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), a needle is commonly used with a stylet, although recently the stylet has been omitted. This prospective study aimed to compare the quality of specimens obtained by EBUS-TBNA performed with and without a stylet. Between November 2013 and November 2014, 131 patients with lung cancer underwent EBUS-TBNA, with a total of 148 mediastinal or hilar lymph nodes sampled both with and without an inner-stylet, yielding 296 cytological specimens. Specimens were scored cytologically using five parameters: background blood or clot, amount of cellular material, degree of cellular degeneration, degree of cellular trauma, and retention of appropriate architecture. The procedure with a stylet required significantly longer operation time than without a stylet (14.5±0.8 vs 12.7±1.1 min, P<0.001). Excellent specimens were obtained in 261/296 and 260/296 samples in the procedures with and without a stylet, respectively (P=0.9), while the remaining 35 and 36 samples, respectively, were adequate. The diagnosing and staging of lung cancer using EBUS-TBNA did not differ significantly between the groups. In conclusion, specimen collection by EBUS-TBNA without a stylet is easier and faster than the procedure using a stylet and absence of a stylet did not alter specimen quality or diagnostic accuracy.
id ABDC-1_21cfe6210892b7b4a229171e8cecc149
oai_identifier_str oai:scielo:S0100-879X2017001000606
network_acronym_str ABDC-1
network_name_str Brazilian Journal of Medical and Biological Research
repository_id_str
spelling Is endobronchial ultrasound-guided transbronchial needle aspiration with a stylet necessary for lymph node screening in lung cancer patients?Endobronchial ultrasound-guidedTransbronchial needle aspirationStyletCytologyPathological diagnosisDuring endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), a needle is commonly used with a stylet, although recently the stylet has been omitted. This prospective study aimed to compare the quality of specimens obtained by EBUS-TBNA performed with and without a stylet. Between November 2013 and November 2014, 131 patients with lung cancer underwent EBUS-TBNA, with a total of 148 mediastinal or hilar lymph nodes sampled both with and without an inner-stylet, yielding 296 cytological specimens. Specimens were scored cytologically using five parameters: background blood or clot, amount of cellular material, degree of cellular degeneration, degree of cellular trauma, and retention of appropriate architecture. The procedure with a stylet required significantly longer operation time than without a stylet (14.5±0.8 vs 12.7±1.1 min, P<0.001). Excellent specimens were obtained in 261/296 and 260/296 samples in the procedures with and without a stylet, respectively (P=0.9), while the remaining 35 and 36 samples, respectively, were adequate. The diagnosing and staging of lung cancer using EBUS-TBNA did not differ significantly between the groups. In conclusion, specimen collection by EBUS-TBNA without a stylet is easier and faster than the procedure using a stylet and absence of a stylet did not alter specimen quality or diagnostic accuracy.Associação Brasileira de Divulgação Científica2017-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2017001000606Brazilian Journal of Medical and Biological Research v.50 n.10 2017reponame:Brazilian Journal of Medical and Biological Researchinstname:Associação Brasileira de Divulgação Científica (ABDC)instacron:ABDC10.1590/1414-431x20176372info:eu-repo/semantics/openAccessXu,Y.Lin,J.Jin,Y.Wu,X.Zheng,H.Feng,J.eng2019-03-19T00:00:00Zoai:scielo:S0100-879X2017001000606Revistahttps://www.bjournal.org/https://old.scielo.br/oai/scielo-oai.phpbjournal@terra.com.br||bjournal@terra.com.br1414-431X0100-879Xopendoar:2019-03-19T00:00Brazilian Journal of Medical and Biological Research - Associação Brasileira de Divulgação Científica (ABDC)false
dc.title.none.fl_str_mv Is endobronchial ultrasound-guided transbronchial needle aspiration with a stylet necessary for lymph node screening in lung cancer patients?
title Is endobronchial ultrasound-guided transbronchial needle aspiration with a stylet necessary for lymph node screening in lung cancer patients?
spellingShingle Is endobronchial ultrasound-guided transbronchial needle aspiration with a stylet necessary for lymph node screening in lung cancer patients?
Xu,Y.
Endobronchial ultrasound-guided
Transbronchial needle aspiration
Stylet
Cytology
Pathological diagnosis
title_short Is endobronchial ultrasound-guided transbronchial needle aspiration with a stylet necessary for lymph node screening in lung cancer patients?
title_full Is endobronchial ultrasound-guided transbronchial needle aspiration with a stylet necessary for lymph node screening in lung cancer patients?
title_fullStr Is endobronchial ultrasound-guided transbronchial needle aspiration with a stylet necessary for lymph node screening in lung cancer patients?
title_full_unstemmed Is endobronchial ultrasound-guided transbronchial needle aspiration with a stylet necessary for lymph node screening in lung cancer patients?
title_sort Is endobronchial ultrasound-guided transbronchial needle aspiration with a stylet necessary for lymph node screening in lung cancer patients?
author Xu,Y.
author_facet Xu,Y.
Lin,J.
Jin,Y.
Wu,X.
Zheng,H.
Feng,J.
author_role author
author2 Lin,J.
Jin,Y.
Wu,X.
Zheng,H.
Feng,J.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Xu,Y.
Lin,J.
Jin,Y.
Wu,X.
Zheng,H.
Feng,J.
dc.subject.por.fl_str_mv Endobronchial ultrasound-guided
Transbronchial needle aspiration
Stylet
Cytology
Pathological diagnosis
topic Endobronchial ultrasound-guided
Transbronchial needle aspiration
Stylet
Cytology
Pathological diagnosis
description During endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), a needle is commonly used with a stylet, although recently the stylet has been omitted. This prospective study aimed to compare the quality of specimens obtained by EBUS-TBNA performed with and without a stylet. Between November 2013 and November 2014, 131 patients with lung cancer underwent EBUS-TBNA, with a total of 148 mediastinal or hilar lymph nodes sampled both with and without an inner-stylet, yielding 296 cytological specimens. Specimens were scored cytologically using five parameters: background blood or clot, amount of cellular material, degree of cellular degeneration, degree of cellular trauma, and retention of appropriate architecture. The procedure with a stylet required significantly longer operation time than without a stylet (14.5±0.8 vs 12.7±1.1 min, P<0.001). Excellent specimens were obtained in 261/296 and 260/296 samples in the procedures with and without a stylet, respectively (P=0.9), while the remaining 35 and 36 samples, respectively, were adequate. The diagnosing and staging of lung cancer using EBUS-TBNA did not differ significantly between the groups. In conclusion, specimen collection by EBUS-TBNA without a stylet is easier and faster than the procedure using a stylet and absence of a stylet did not alter specimen quality or diagnostic accuracy.
publishDate 2017
dc.date.none.fl_str_mv 2017-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2017001000606
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2017001000606
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1414-431x20176372
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Divulgação Científica
publisher.none.fl_str_mv Associação Brasileira de Divulgação Científica
dc.source.none.fl_str_mv Brazilian Journal of Medical and Biological Research v.50 n.10 2017
reponame:Brazilian Journal of Medical and Biological Research
instname:Associação Brasileira de Divulgação Científica (ABDC)
instacron:ABDC
instname_str Associação Brasileira de Divulgação Científica (ABDC)
instacron_str ABDC
institution ABDC
reponame_str Brazilian Journal of Medical and Biological Research
collection Brazilian Journal of Medical and Biological Research
repository.name.fl_str_mv Brazilian Journal of Medical and Biological Research - Associação Brasileira de Divulgação Científica (ABDC)
repository.mail.fl_str_mv bjournal@terra.com.br||bjournal@terra.com.br
_version_ 1754302945867857920