Tracheal cuff pressure change before and after the performance of nursing care
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Enfermagem (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-71672017000601145 |
Resumo: | ABSTRACT Objective: Verify the changes of endotracheal cuff pressure before and after oral hygiene, head-of-bed elevation at 0º, 30º, and 60º, change in body position, aspiration of the endotracheal tube, and in-bed bathing. Method: The study sample was composed of 88 patients. We performed 3,696 checks from July to September 2014. Results: Pressure values were analyzed in seven nursing care in the morning. Six of them were significantly altered before and after nursing procedure. In the afternoon, five of the health care provided were altered, and in the evening, only two. Most of pressure values were below recommended. Conclusion: There were differences before and after health care provided, showing changes in cuff pressure. In-bed bathing and head-of-bed elevation at 30º were the ones that most altered pressure values in the three working shifts. Therefore, it is necessary to measure cuff pressure at least twice per working shift, preferably after bathing. |
id |
ABEN-1_2de1fff168dd6b237612ab9aacf7b5e8 |
---|---|
oai_identifier_str |
oai:scielo:S0034-71672017000601145 |
network_acronym_str |
ABEN-1 |
network_name_str |
Revista Brasileira de Enfermagem (Online) |
repository_id_str |
|
spelling |
Tracheal cuff pressure change before and after the performance of nursing careIntubation, IntratrachealPressureIntensive Care UnitsNursingPatientABSTRACT Objective: Verify the changes of endotracheal cuff pressure before and after oral hygiene, head-of-bed elevation at 0º, 30º, and 60º, change in body position, aspiration of the endotracheal tube, and in-bed bathing. Method: The study sample was composed of 88 patients. We performed 3,696 checks from July to September 2014. Results: Pressure values were analyzed in seven nursing care in the morning. Six of them were significantly altered before and after nursing procedure. In the afternoon, five of the health care provided were altered, and in the evening, only two. Most of pressure values were below recommended. Conclusion: There were differences before and after health care provided, showing changes in cuff pressure. In-bed bathing and head-of-bed elevation at 30º were the ones that most altered pressure values in the three working shifts. Therefore, it is necessary to measure cuff pressure at least twice per working shift, preferably after bathing.Associação Brasileira de Enfermagem2017-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-71672017000601145Revista Brasileira de Enfermagem v.70 n.6 2017reponame:Revista Brasileira de Enfermagem (Online)instname:Associação Brasileira de Enfermagem (ABEN)instacron:ABEN10.1590/0034-7167-2016-0486info:eu-repo/semantics/openAccessBeccaria,Lúcia MarinilzaDoimo,Thays Marley AntonioPolletti,Nádia Aparecida AntoniaBarbosa,Tais PagliucoSilva,Daniele Cristiny daWerneck,Alexandre Linseng2017-11-10T00:00:00Zoai:scielo:S0034-71672017000601145Revistahttp://www.scielo.br/rebenhttps://old.scielo.br/oai/scielo-oai.phpreben@abennacional.org.br||telma.garcia@abennacional.org.br|| editorreben@abennacional.org.br1984-04460034-7167opendoar:2017-11-10T00:00Revista Brasileira de Enfermagem (Online) - Associação Brasileira de Enfermagem (ABEN)false |
dc.title.none.fl_str_mv |
Tracheal cuff pressure change before and after the performance of nursing care |
title |
Tracheal cuff pressure change before and after the performance of nursing care |
spellingShingle |
Tracheal cuff pressure change before and after the performance of nursing care Beccaria,Lúcia Marinilza Intubation, Intratracheal Pressure Intensive Care Units Nursing Patient |
title_short |
Tracheal cuff pressure change before and after the performance of nursing care |
title_full |
Tracheal cuff pressure change before and after the performance of nursing care |
title_fullStr |
Tracheal cuff pressure change before and after the performance of nursing care |
title_full_unstemmed |
Tracheal cuff pressure change before and after the performance of nursing care |
title_sort |
Tracheal cuff pressure change before and after the performance of nursing care |
author |
Beccaria,Lúcia Marinilza |
author_facet |
Beccaria,Lúcia Marinilza Doimo,Thays Marley Antonio Polletti,Nádia Aparecida Antonia Barbosa,Tais Pagliuco Silva,Daniele Cristiny da Werneck,Alexandre Lins |
author_role |
author |
author2 |
Doimo,Thays Marley Antonio Polletti,Nádia Aparecida Antonia Barbosa,Tais Pagliuco Silva,Daniele Cristiny da Werneck,Alexandre Lins |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Beccaria,Lúcia Marinilza Doimo,Thays Marley Antonio Polletti,Nádia Aparecida Antonia Barbosa,Tais Pagliuco Silva,Daniele Cristiny da Werneck,Alexandre Lins |
dc.subject.por.fl_str_mv |
Intubation, Intratracheal Pressure Intensive Care Units Nursing Patient |
topic |
Intubation, Intratracheal Pressure Intensive Care Units Nursing Patient |
description |
ABSTRACT Objective: Verify the changes of endotracheal cuff pressure before and after oral hygiene, head-of-bed elevation at 0º, 30º, and 60º, change in body position, aspiration of the endotracheal tube, and in-bed bathing. Method: The study sample was composed of 88 patients. We performed 3,696 checks from July to September 2014. Results: Pressure values were analyzed in seven nursing care in the morning. Six of them were significantly altered before and after nursing procedure. In the afternoon, five of the health care provided were altered, and in the evening, only two. Most of pressure values were below recommended. Conclusion: There were differences before and after health care provided, showing changes in cuff pressure. In-bed bathing and head-of-bed elevation at 30º were the ones that most altered pressure values in the three working shifts. Therefore, it is necessary to measure cuff pressure at least twice per working shift, preferably after bathing. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-71672017000601145 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-71672017000601145 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0034-7167-2016-0486 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Enfermagem |
publisher.none.fl_str_mv |
Associação Brasileira de Enfermagem |
dc.source.none.fl_str_mv |
Revista Brasileira de Enfermagem v.70 n.6 2017 reponame:Revista Brasileira de Enfermagem (Online) instname:Associação Brasileira de Enfermagem (ABEN) instacron:ABEN |
instname_str |
Associação Brasileira de Enfermagem (ABEN) |
instacron_str |
ABEN |
institution |
ABEN |
reponame_str |
Revista Brasileira de Enfermagem (Online) |
collection |
Revista Brasileira de Enfermagem (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Enfermagem (Online) - Associação Brasileira de Enfermagem (ABEN) |
repository.mail.fl_str_mv |
reben@abennacional.org.br||telma.garcia@abennacional.org.br|| editorreben@abennacional.org.br |
_version_ |
1754303034028982272 |