Effect of light intensity and irradiation time on the polymerization process of a dental composite resin
Autor(a) principal: | |
---|---|
Data de Publicação: | 2004 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Materials research (São Carlos. Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392004000200015 |
Resumo: | Polymerization shrinkage is a critical factor affecting the longevity and acceptability of dental composite resins. The aim of this work was to evaluate the effect of light intensity and irradiation time on the polymerization process of a photo cured dental composite resin by measuring the Vickers hardness number (VHN) and the volumetric polymerization shrinkage. Samples were prepared using a dental manual light-curing unit. The samples were submitted to irradiation times of 5, 10, 20 and 40 s, using 200 and 400 mW.cm-2 light intensities. Vickers hardness number was obtained at four different moments after photoactivation (immediate, 1 h, 24 h and 168 h). After this, volumetric polymerization shrinkage values were obtained through a specific density method. The values were analyzed by ANOVA and Duncan's (p = 0.05). Results showed increase in hardness values from the immediate reading to 1 h and 24 h readings. After 24 h no changes were observed regardless the light intensities or activation times. The hardness values were always smaller for the 200 mW.cm-2 light intensity, except for the 40 s irradiation time. No significant differences were detected in volumetric polymerization shrinkage considering the light intensity (p = 0.539) and the activation time (p = 0.637) factors. In conclusion the polymerization of the material does not terminate immediately after photoactivation and the increase of irradiation time can compensate a lower light intensity. Different combinations between light intensity and irradiation time, i.e., different amounts of energy given to the system, have not affected the polymerization shrinkage. |
id |
ABMABCABPOL-1_435b74c57e4a69717f24e1980303306a |
---|---|
oai_identifier_str |
oai:scielo:S1516-14392004000200015 |
network_acronym_str |
ABMABCABPOL-1 |
network_name_str |
Materials research (São Carlos. Online) |
repository_id_str |
|
spelling |
Effect of light intensity and irradiation time on the polymerization process of a dental composite resinphotoactivationirradiation timelight intensitypolymerization shrinkagehardnessPolymerization shrinkage is a critical factor affecting the longevity and acceptability of dental composite resins. The aim of this work was to evaluate the effect of light intensity and irradiation time on the polymerization process of a photo cured dental composite resin by measuring the Vickers hardness number (VHN) and the volumetric polymerization shrinkage. Samples were prepared using a dental manual light-curing unit. The samples were submitted to irradiation times of 5, 10, 20 and 40 s, using 200 and 400 mW.cm-2 light intensities. Vickers hardness number was obtained at four different moments after photoactivation (immediate, 1 h, 24 h and 168 h). After this, volumetric polymerization shrinkage values were obtained through a specific density method. The values were analyzed by ANOVA and Duncan's (p = 0.05). Results showed increase in hardness values from the immediate reading to 1 h and 24 h readings. After 24 h no changes were observed regardless the light intensities or activation times. The hardness values were always smaller for the 200 mW.cm-2 light intensity, except for the 40 s irradiation time. No significant differences were detected in volumetric polymerization shrinkage considering the light intensity (p = 0.539) and the activation time (p = 0.637) factors. In conclusion the polymerization of the material does not terminate immediately after photoactivation and the increase of irradiation time can compensate a lower light intensity. Different combinations between light intensity and irradiation time, i.e., different amounts of energy given to the system, have not affected the polymerization shrinkage.ABM, ABC, ABPol2004-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392004000200015Materials Research v.7 n.2 2004reponame:Materials research (São Carlos. Online)instname:Universidade Federal de São Carlos (UFSCAR)instacron:ABM ABC ABPOL10.1590/S1516-14392004000200015info:eu-repo/semantics/openAccessDiscacciati,José Augusto CésarNeves,Alisson DiscacciatiOréfice,Rodrigo LambertPimenta,Flávio Juliano Garcia SantosSander,Herbert Haueiseneng2004-06-29T00:00:00Zoai:scielo:S1516-14392004000200015Revistahttp://www.scielo.br/mrPUBhttps://old.scielo.br/oai/scielo-oai.phpdedz@power.ufscar.br1980-53731516-1439opendoar:2004-06-29T00:00Materials research (São Carlos. Online) - Universidade Federal de São Carlos (UFSCAR)false |
dc.title.none.fl_str_mv |
Effect of light intensity and irradiation time on the polymerization process of a dental composite resin |
title |
Effect of light intensity and irradiation time on the polymerization process of a dental composite resin |
spellingShingle |
Effect of light intensity and irradiation time on the polymerization process of a dental composite resin Discacciati,José Augusto César photoactivation irradiation time light intensity polymerization shrinkage hardness |
title_short |
Effect of light intensity and irradiation time on the polymerization process of a dental composite resin |
title_full |
Effect of light intensity and irradiation time on the polymerization process of a dental composite resin |
title_fullStr |
Effect of light intensity and irradiation time on the polymerization process of a dental composite resin |
title_full_unstemmed |
Effect of light intensity and irradiation time on the polymerization process of a dental composite resin |
title_sort |
Effect of light intensity and irradiation time on the polymerization process of a dental composite resin |
author |
Discacciati,José Augusto César |
author_facet |
Discacciati,José Augusto César Neves,Alisson Discacciati Oréfice,Rodrigo Lambert Pimenta,Flávio Juliano Garcia Santos Sander,Herbert Haueisen |
author_role |
author |
author2 |
Neves,Alisson Discacciati Oréfice,Rodrigo Lambert Pimenta,Flávio Juliano Garcia Santos Sander,Herbert Haueisen |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Discacciati,José Augusto César Neves,Alisson Discacciati Oréfice,Rodrigo Lambert Pimenta,Flávio Juliano Garcia Santos Sander,Herbert Haueisen |
dc.subject.por.fl_str_mv |
photoactivation irradiation time light intensity polymerization shrinkage hardness |
topic |
photoactivation irradiation time light intensity polymerization shrinkage hardness |
description |
Polymerization shrinkage is a critical factor affecting the longevity and acceptability of dental composite resins. The aim of this work was to evaluate the effect of light intensity and irradiation time on the polymerization process of a photo cured dental composite resin by measuring the Vickers hardness number (VHN) and the volumetric polymerization shrinkage. Samples were prepared using a dental manual light-curing unit. The samples were submitted to irradiation times of 5, 10, 20 and 40 s, using 200 and 400 mW.cm-2 light intensities. Vickers hardness number was obtained at four different moments after photoactivation (immediate, 1 h, 24 h and 168 h). After this, volumetric polymerization shrinkage values were obtained through a specific density method. The values were analyzed by ANOVA and Duncan's (p = 0.05). Results showed increase in hardness values from the immediate reading to 1 h and 24 h readings. After 24 h no changes were observed regardless the light intensities or activation times. The hardness values were always smaller for the 200 mW.cm-2 light intensity, except for the 40 s irradiation time. No significant differences were detected in volumetric polymerization shrinkage considering the light intensity (p = 0.539) and the activation time (p = 0.637) factors. In conclusion the polymerization of the material does not terminate immediately after photoactivation and the increase of irradiation time can compensate a lower light intensity. Different combinations between light intensity and irradiation time, i.e., different amounts of energy given to the system, have not affected the polymerization shrinkage. |
publishDate |
2004 |
dc.date.none.fl_str_mv |
2004-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392004000200015 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392004000200015 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1516-14392004000200015 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
ABM, ABC, ABPol |
publisher.none.fl_str_mv |
ABM, ABC, ABPol |
dc.source.none.fl_str_mv |
Materials Research v.7 n.2 2004 reponame:Materials research (São Carlos. Online) instname:Universidade Federal de São Carlos (UFSCAR) instacron:ABM ABC ABPOL |
instname_str |
Universidade Federal de São Carlos (UFSCAR) |
instacron_str |
ABM ABC ABPOL |
institution |
ABM ABC ABPOL |
reponame_str |
Materials research (São Carlos. Online) |
collection |
Materials research (São Carlos. Online) |
repository.name.fl_str_mv |
Materials research (São Carlos. Online) - Universidade Federal de São Carlos (UFSCAR) |
repository.mail.fl_str_mv |
dedz@power.ufscar.br |
_version_ |
1754212657708138496 |