Resumo: Polymerization shrinkage is a critical factor affecting the longevity and acceptability of dental composite resins. The aim of this work was to evaluate the effect of light intensity and irradiation time on the polymerization process of a photo cured dental composite resin by measuring the Vickers hardness number (VHN) and the volumetric polymerization shrinkage. Samples were prepared using a dental manual light-curing unit. The samples were submitted to irradiation times of 5, 10, 20 and 40 s, using 200 and 400 mW.cm-2 light intensities. Vickers hardness number was obtained at four different moments after photoactivation (immediate, 1 h, 24 h and 168 h). After this, volumetric polymerization shrinkage values were obtained through a specific density method. The values were analyzed by ANOVA and Duncan's (p = 0.05). Results showed increase in hardness values from the immediate reading to 1 h and 24 h readings. After 24 h no changes were observed regardless the light intensities or activation times. The hardness values were always smaller for the 200 mW.cm-2 light intensity, except for the 40 s irradiation time. No significant differences were detected in volumetric polymerization shrinkage considering the light intensity (p = 0.539) and the activation time (p = 0.637) factors. In conclusion the polymerization of the material does not terminate immediately after photoactivation and the increase of irradiation time can compensate a lower light intensity. Different combinations between light intensity and irradiation time, i.e., different amounts of energy given to the system, have not affected the polymerization shrinkage.
id ABMABCABPOL-1_435b74c57e4a69717f24e1980303306a
oai_identifier_str oai:scielo:S1516-14392004000200015
network_acronym_str ABMABCABPOL-1
network_name_str Materials research (São Carlos. Online)
repository_id_str
spelling Effect of light intensity and irradiation time on the polymerization process of a dental composite resinphotoactivationirradiation timelight intensitypolymerization shrinkagehardnessPolymerization shrinkage is a critical factor affecting the longevity and acceptability of dental composite resins. The aim of this work was to evaluate the effect of light intensity and irradiation time on the polymerization process of a photo cured dental composite resin by measuring the Vickers hardness number (VHN) and the volumetric polymerization shrinkage. Samples were prepared using a dental manual light-curing unit. The samples were submitted to irradiation times of 5, 10, 20 and 40 s, using 200 and 400 mW.cm-2 light intensities. Vickers hardness number was obtained at four different moments after photoactivation (immediate, 1 h, 24 h and 168 h). After this, volumetric polymerization shrinkage values were obtained through a specific density method. The values were analyzed by ANOVA and Duncan's (p = 0.05). Results showed increase in hardness values from the immediate reading to 1 h and 24 h readings. After 24 h no changes were observed regardless the light intensities or activation times. The hardness values were always smaller for the 200 mW.cm-2 light intensity, except for the 40 s irradiation time. No significant differences were detected in volumetric polymerization shrinkage considering the light intensity (p = 0.539) and the activation time (p = 0.637) factors. In conclusion the polymerization of the material does not terminate immediately after photoactivation and the increase of irradiation time can compensate a lower light intensity. Different combinations between light intensity and irradiation time, i.e., different amounts of energy given to the system, have not affected the polymerization shrinkage.ABM, ABC, ABPol2004-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392004000200015Materials Research v.7 n.2 2004reponame:Materials research (São Carlos. Online)instname:Universidade Federal de São Carlos (UFSCAR)instacron:ABM ABC ABPOL10.1590/S1516-14392004000200015info:eu-repo/semantics/openAccessDiscacciati,José Augusto CésarNeves,Alisson DiscacciatiOréfice,Rodrigo LambertPimenta,Flávio Juliano Garcia SantosSander,Herbert Haueiseneng2004-06-29T00:00:00Zoai:scielo:S1516-14392004000200015Revistahttp://www.scielo.br/mrPUBhttps://old.scielo.br/oai/scielo-oai.phpdedz@power.ufscar.br1980-53731516-1439opendoar:2004-06-29T00:00Materials research (São Carlos. Online) - Universidade Federal de São Carlos (UFSCAR)false
dc.title.none.fl_str_mv Effect of light intensity and irradiation time on the polymerization process of a dental composite resin
title Effect of light intensity and irradiation time on the polymerization process of a dental composite resin
spellingShingle Effect of light intensity and irradiation time on the polymerization process of a dental composite resin
Discacciati,José Augusto César
photoactivation
irradiation time
light intensity
polymerization shrinkage
hardness
title_short Effect of light intensity and irradiation time on the polymerization process of a dental composite resin
title_full Effect of light intensity and irradiation time on the polymerization process of a dental composite resin
title_fullStr Effect of light intensity and irradiation time on the polymerization process of a dental composite resin
title_full_unstemmed Effect of light intensity and irradiation time on the polymerization process of a dental composite resin
title_sort Effect of light intensity and irradiation time on the polymerization process of a dental composite resin
author Discacciati,José Augusto César
author_facet Discacciati,José Augusto César
Neves,Alisson Discacciati
Oréfice,Rodrigo Lambert
Pimenta,Flávio Juliano Garcia Santos
Sander,Herbert Haueisen
author_role author
author2 Neves,Alisson Discacciati
Oréfice,Rodrigo Lambert
Pimenta,Flávio Juliano Garcia Santos
Sander,Herbert Haueisen
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Discacciati,José Augusto César
Neves,Alisson Discacciati
Oréfice,Rodrigo Lambert
Pimenta,Flávio Juliano Garcia Santos
Sander,Herbert Haueisen
dc.subject.por.fl_str_mv photoactivation
irradiation time
light intensity
polymerization shrinkage
hardness
topic photoactivation
irradiation time
light intensity
polymerization shrinkage
hardness
description Polymerization shrinkage is a critical factor affecting the longevity and acceptability of dental composite resins. The aim of this work was to evaluate the effect of light intensity and irradiation time on the polymerization process of a photo cured dental composite resin by measuring the Vickers hardness number (VHN) and the volumetric polymerization shrinkage. Samples were prepared using a dental manual light-curing unit. The samples were submitted to irradiation times of 5, 10, 20 and 40 s, using 200 and 400 mW.cm-2 light intensities. Vickers hardness number was obtained at four different moments after photoactivation (immediate, 1 h, 24 h and 168 h). After this, volumetric polymerization shrinkage values were obtained through a specific density method. The values were analyzed by ANOVA and Duncan's (p = 0.05). Results showed increase in hardness values from the immediate reading to 1 h and 24 h readings. After 24 h no changes were observed regardless the light intensities or activation times. The hardness values were always smaller for the 200 mW.cm-2 light intensity, except for the 40 s irradiation time. No significant differences were detected in volumetric polymerization shrinkage considering the light intensity (p = 0.539) and the activation time (p = 0.637) factors. In conclusion the polymerization of the material does not terminate immediately after photoactivation and the increase of irradiation time can compensate a lower light intensity. Different combinations between light intensity and irradiation time, i.e., different amounts of energy given to the system, have not affected the polymerization shrinkage.
publishDate 2004
dc.date.none.fl_str_mv 2004-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392004000200015
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392004000200015
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1516-14392004000200015
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv ABM, ABC, ABPol
publisher.none.fl_str_mv ABM, ABC, ABPol
dc.source.none.fl_str_mv Materials Research v.7 n.2 2004
reponame:Materials research (São Carlos. Online)
instname:Universidade Federal de São Carlos (UFSCAR)
instacron:ABM ABC ABPOL
instname_str Universidade Federal de São Carlos (UFSCAR)
instacron_str ABM ABC ABPOL
institution ABM ABC ABPOL
reponame_str Materials research (São Carlos. Online)
collection Materials research (São Carlos. Online)
repository.name.fl_str_mv Materials research (São Carlos. Online) - Universidade Federal de São Carlos (UFSCAR)
repository.mail.fl_str_mv dedz@power.ufscar.br
_version_ 1754212657708138496