Is it possible to re-use mini-implants for orthodontic anchorage? Results of an in vitro study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Materials research (São Carlos. Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392010000400015 |
Resumo: | The aim of this study was to compare the surface morphology and fracture torque resistance of as-received, sterilized and retrieved mini-implants in order to evaluate the fracture risks of re-using orthodontic mini-implants after sterilization. Thirty mini-implants retrieved from 19 patients, twenty as-received and twenty autoclaved mini-implants from the same manufacturer were used in this study. Ten samples from each group were analyzed by scanning electron microscopy and the remaining specimens were tested for their fracture torque resistance. Results were statistically analyzed using one-way ANOVA. No defects or corrosion could be identified in autoclaved and retrieved mini-implants, but a worn surface and scratch marks could be observed on the retrieved ones. A statistical significant difference in the fracture torque was observed between the as-received and the retrieved groups. Re-use of retrieved mini-implants should not be recommended because their torque resistance is reduced. As-received mini-implants submitted to autoclave sterilization can be recommended to be used clinically. |
id |
ABMABCABPOL-1_c4434817e28b826fe24ae9c232db7bd1 |
---|---|
oai_identifier_str |
oai:scielo:S1516-14392010000400015 |
network_acronym_str |
ABMABCABPOL-1 |
network_name_str |
Materials research (São Carlos. Online) |
repository_id_str |
|
spelling |
Is it possible to re-use mini-implants for orthodontic anchorage? Results of an in vitro studyimplant fracturere-useScanning Electron Microscopy (SEM)sterilizationThe aim of this study was to compare the surface morphology and fracture torque resistance of as-received, sterilized and retrieved mini-implants in order to evaluate the fracture risks of re-using orthodontic mini-implants after sterilization. Thirty mini-implants retrieved from 19 patients, twenty as-received and twenty autoclaved mini-implants from the same manufacturer were used in this study. Ten samples from each group were analyzed by scanning electron microscopy and the remaining specimens were tested for their fracture torque resistance. Results were statistically analyzed using one-way ANOVA. No defects or corrosion could be identified in autoclaved and retrieved mini-implants, but a worn surface and scratch marks could be observed on the retrieved ones. A statistical significant difference in the fracture torque was observed between the as-received and the retrieved groups. Re-use of retrieved mini-implants should not be recommended because their torque resistance is reduced. As-received mini-implants submitted to autoclave sterilization can be recommended to be used clinically.ABM, ABC, ABPol2010-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392010000400015Materials Research v.13 n.4 2010reponame:Materials research (São Carlos. Online)instname:Universidade Federal de São Carlos (UFSCAR)instacron:ABM ABC ABPOL10.1590/S1516-14392010000400015info:eu-repo/semantics/openAccessMattos,Cláudia TrindadeRuellas,Antônio Carlos de OliveiraElias,Carlos Nelsoneng2011-01-24T00:00:00Zoai:scielo:S1516-14392010000400015Revistahttp://www.scielo.br/mrPUBhttps://old.scielo.br/oai/scielo-oai.phpdedz@power.ufscar.br1980-53731516-1439opendoar:2011-01-24T00:00Materials research (São Carlos. Online) - Universidade Federal de São Carlos (UFSCAR)false |
dc.title.none.fl_str_mv |
Is it possible to re-use mini-implants for orthodontic anchorage? Results of an in vitro study |
title |
Is it possible to re-use mini-implants for orthodontic anchorage? Results of an in vitro study |
spellingShingle |
Is it possible to re-use mini-implants for orthodontic anchorage? Results of an in vitro study Mattos,Cláudia Trindade implant fracture re-use Scanning Electron Microscopy (SEM) sterilization |
title_short |
Is it possible to re-use mini-implants for orthodontic anchorage? Results of an in vitro study |
title_full |
Is it possible to re-use mini-implants for orthodontic anchorage? Results of an in vitro study |
title_fullStr |
Is it possible to re-use mini-implants for orthodontic anchorage? Results of an in vitro study |
title_full_unstemmed |
Is it possible to re-use mini-implants for orthodontic anchorage? Results of an in vitro study |
title_sort |
Is it possible to re-use mini-implants for orthodontic anchorage? Results of an in vitro study |
author |
Mattos,Cláudia Trindade |
author_facet |
Mattos,Cláudia Trindade Ruellas,Antônio Carlos de Oliveira Elias,Carlos Nelson |
author_role |
author |
author2 |
Ruellas,Antônio Carlos de Oliveira Elias,Carlos Nelson |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Mattos,Cláudia Trindade Ruellas,Antônio Carlos de Oliveira Elias,Carlos Nelson |
dc.subject.por.fl_str_mv |
implant fracture re-use Scanning Electron Microscopy (SEM) sterilization |
topic |
implant fracture re-use Scanning Electron Microscopy (SEM) sterilization |
description |
The aim of this study was to compare the surface morphology and fracture torque resistance of as-received, sterilized and retrieved mini-implants in order to evaluate the fracture risks of re-using orthodontic mini-implants after sterilization. Thirty mini-implants retrieved from 19 patients, twenty as-received and twenty autoclaved mini-implants from the same manufacturer were used in this study. Ten samples from each group were analyzed by scanning electron microscopy and the remaining specimens were tested for their fracture torque resistance. Results were statistically analyzed using one-way ANOVA. No defects or corrosion could be identified in autoclaved and retrieved mini-implants, but a worn surface and scratch marks could be observed on the retrieved ones. A statistical significant difference in the fracture torque was observed between the as-received and the retrieved groups. Re-use of retrieved mini-implants should not be recommended because their torque resistance is reduced. As-received mini-implants submitted to autoclave sterilization can be recommended to be used clinically. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392010000400015 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392010000400015 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1516-14392010000400015 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
ABM, ABC, ABPol |
publisher.none.fl_str_mv |
ABM, ABC, ABPol |
dc.source.none.fl_str_mv |
Materials Research v.13 n.4 2010 reponame:Materials research (São Carlos. Online) instname:Universidade Federal de São Carlos (UFSCAR) instacron:ABM ABC ABPOL |
instname_str |
Universidade Federal de São Carlos (UFSCAR) |
instacron_str |
ABM ABC ABPOL |
institution |
ABM ABC ABPOL |
reponame_str |
Materials research (São Carlos. Online) |
collection |
Materials research (São Carlos. Online) |
repository.name.fl_str_mv |
Materials research (São Carlos. Online) - Universidade Federal de São Carlos (UFSCAR) |
repository.mail.fl_str_mv |
dedz@power.ufscar.br |
_version_ |
1754212659714064384 |