Clinical experience with a novel bovine collagen dura mater substitute
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos de neuro-psiquiatria (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2011000200015 |
Resumo: | Dural substitutes are used to achieve watertight closure of the dura mater when adequate closure is not possible. The purpose of this study was to evaluate the efficacy and safety of a new collagen matrix dural substitute (Duradry, Technodry, Belo Horizonte MG) in the repair or expansion of cranial and spinal dura mater. METHOD: Thirty patients, operated on between March and September, 2008, were studied. Surgical records were reviewed for sex, age, location of graft, technique, and presence of fistula or infection. The patients were followed up for at least 3 months, and presence of complications, such as cerebrospinal fluid leakage, infection, asseptic meningitis hydrocephalus, pseudomeningocele, was analyzed. RESULTS: Only one patient presented cerebrospinal fluid fistula. No patients presented wound infections, hydrocephalus, pseudomenigocele, meningites, brain abscesses or signs of toxicity related to the dural substitute. CONCLUSION: The new dural substitute used in this study is effective and safe, and the initial results are similar to those of other dural substitutes reported in the literature. |
id |
ABNEURO-1_0d3ceb123f71ba5417c56aa8d1daee36 |
---|---|
oai_identifier_str |
oai:scielo:S0004-282X2011000200015 |
network_acronym_str |
ABNEURO-1 |
network_name_str |
Arquivos de neuro-psiquiatria (Online) |
repository_id_str |
|
spelling |
Clinical experience with a novel bovine collagen dura mater substitutecerebrospinal fluid leakduraplastycollagen matrixDural substitutes are used to achieve watertight closure of the dura mater when adequate closure is not possible. The purpose of this study was to evaluate the efficacy and safety of a new collagen matrix dural substitute (Duradry, Technodry, Belo Horizonte MG) in the repair or expansion of cranial and spinal dura mater. METHOD: Thirty patients, operated on between March and September, 2008, were studied. Surgical records were reviewed for sex, age, location of graft, technique, and presence of fistula or infection. The patients were followed up for at least 3 months, and presence of complications, such as cerebrospinal fluid leakage, infection, asseptic meningitis hydrocephalus, pseudomeningocele, was analyzed. RESULTS: Only one patient presented cerebrospinal fluid fistula. No patients presented wound infections, hydrocephalus, pseudomenigocele, meningites, brain abscesses or signs of toxicity related to the dural substitute. CONCLUSION: The new dural substitute used in this study is effective and safe, and the initial results are similar to those of other dural substitutes reported in the literature.Academia Brasileira de Neurologia - ABNEURO2011-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2011000200015Arquivos de Neuro-Psiquiatria v.69 n.2a 2011reponame:Arquivos de neuro-psiquiatria (Online)instname:Academia Brasileira de Neurologiainstacron:ABNEURO10.1590/S0004-282X2011000200015info:eu-repo/semantics/openAccessCosta,Bruno SilvaCavalcanti-Mendes,George de AlbuquerqueAbreu,Marcelo Sartori deSousa,Atos Alves deeng2011-04-26T00:00:00Zoai:scielo:S0004-282X2011000200015Revistahttp://www.scielo.br/anphttps://old.scielo.br/oai/scielo-oai.php||revista.arquivos@abneuro.org1678-42270004-282Xopendoar:2011-04-26T00:00Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologiafalse |
dc.title.none.fl_str_mv |
Clinical experience with a novel bovine collagen dura mater substitute |
title |
Clinical experience with a novel bovine collagen dura mater substitute |
spellingShingle |
Clinical experience with a novel bovine collagen dura mater substitute Costa,Bruno Silva cerebrospinal fluid leak duraplasty collagen matrix |
title_short |
Clinical experience with a novel bovine collagen dura mater substitute |
title_full |
Clinical experience with a novel bovine collagen dura mater substitute |
title_fullStr |
Clinical experience with a novel bovine collagen dura mater substitute |
title_full_unstemmed |
Clinical experience with a novel bovine collagen dura mater substitute |
title_sort |
Clinical experience with a novel bovine collagen dura mater substitute |
author |
Costa,Bruno Silva |
author_facet |
Costa,Bruno Silva Cavalcanti-Mendes,George de Albuquerque Abreu,Marcelo Sartori de Sousa,Atos Alves de |
author_role |
author |
author2 |
Cavalcanti-Mendes,George de Albuquerque Abreu,Marcelo Sartori de Sousa,Atos Alves de |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Costa,Bruno Silva Cavalcanti-Mendes,George de Albuquerque Abreu,Marcelo Sartori de Sousa,Atos Alves de |
dc.subject.por.fl_str_mv |
cerebrospinal fluid leak duraplasty collagen matrix |
topic |
cerebrospinal fluid leak duraplasty collagen matrix |
description |
Dural substitutes are used to achieve watertight closure of the dura mater when adequate closure is not possible. The purpose of this study was to evaluate the efficacy and safety of a new collagen matrix dural substitute (Duradry, Technodry, Belo Horizonte MG) in the repair or expansion of cranial and spinal dura mater. METHOD: Thirty patients, operated on between March and September, 2008, were studied. Surgical records were reviewed for sex, age, location of graft, technique, and presence of fistula or infection. The patients were followed up for at least 3 months, and presence of complications, such as cerebrospinal fluid leakage, infection, asseptic meningitis hydrocephalus, pseudomeningocele, was analyzed. RESULTS: Only one patient presented cerebrospinal fluid fistula. No patients presented wound infections, hydrocephalus, pseudomenigocele, meningites, brain abscesses or signs of toxicity related to the dural substitute. CONCLUSION: The new dural substitute used in this study is effective and safe, and the initial results are similar to those of other dural substitutes reported in the literature. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2011000200015 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2011000200015 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0004-282X2011000200015 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Academia Brasileira de Neurologia - ABNEURO |
publisher.none.fl_str_mv |
Academia Brasileira de Neurologia - ABNEURO |
dc.source.none.fl_str_mv |
Arquivos de Neuro-Psiquiatria v.69 n.2a 2011 reponame:Arquivos de neuro-psiquiatria (Online) instname:Academia Brasileira de Neurologia instacron:ABNEURO |
instname_str |
Academia Brasileira de Neurologia |
instacron_str |
ABNEURO |
institution |
ABNEURO |
reponame_str |
Arquivos de neuro-psiquiatria (Online) |
collection |
Arquivos de neuro-psiquiatria (Online) |
repository.name.fl_str_mv |
Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologia |
repository.mail.fl_str_mv |
||revista.arquivos@abneuro.org |
_version_ |
1754212770562179072 |