Comparison of two systems for the video head impulse test (vHIT) for the lateral semicircular canal: description of results from normal and pathological subjects
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos de neuro-psiquiatria (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2021000700571 |
Resumo: | ABSTRACT Background: The video head impulse test (vHIT) is a recent technique for functional evaluation of semicircular canals (SSCs). The vHIT examines eye movements at high frequencies of stimulation and provides an objective assessment of the functioning of the high-frequency domain of the vestibular system. Objective: To describe the results from vHIT performed using two systems. Methods: All subjects were evaluated through an audiological and otoneurological battery of tests and were diagnosed as normal or abnormal by an otorhinolaryngologist. The results from two systems: 1. ICS Impulse (Otometrics/Natus, Denmark) and 2. EyeSeeCam (InterAcoustics, Denmark) were recorded. The same operator delivered every impulse to every subject. The head impulses were performed while the operator was standing behind the subject, using both hands on the top of the subject’s head, well away from the goggles strap and forehead skin. Two calibrations were completed in each system, prior to beginning the test. Results: Test parameters were recorded through both systems for healthy subjects with no history or complaint of any vestibular disorder (N = 12; M/F = 5/7; age 35.1 ± 13.5 y) and for pathological subjects with a diagnosis of unilateral or bilateral vestibular disorder (N = 15; M/F = 7/8; age 53.4 ± 16.7 y). Conclusions: The vHIT is an important tool for otoneurological complementary evaluation. Both systems are reliable for vestibular disorders. The EyeSeeCam seems to reject fewer data and provides more information to include in diagnostics. Because of the small sample, there is a need for further in-depth comparison of both systems. |
id |
ABNEURO-1_3c3e031ebffe940e1012fdd025bd1d7f |
---|---|
oai_identifier_str |
oai:scielo:S0004-282X2021000700571 |
network_acronym_str |
ABNEURO-1 |
network_name_str |
Arquivos de neuro-psiquiatria (Online) |
repository_id_str |
|
spelling |
Comparison of two systems for the video head impulse test (vHIT) for the lateral semicircular canal: description of results from normal and pathological subjectsDiagnosisHead Impulse TestPostural BalanceSemicircular CanalsVestibular Function TestsABSTRACT Background: The video head impulse test (vHIT) is a recent technique for functional evaluation of semicircular canals (SSCs). The vHIT examines eye movements at high frequencies of stimulation and provides an objective assessment of the functioning of the high-frequency domain of the vestibular system. Objective: To describe the results from vHIT performed using two systems. Methods: All subjects were evaluated through an audiological and otoneurological battery of tests and were diagnosed as normal or abnormal by an otorhinolaryngologist. The results from two systems: 1. ICS Impulse (Otometrics/Natus, Denmark) and 2. EyeSeeCam (InterAcoustics, Denmark) were recorded. The same operator delivered every impulse to every subject. The head impulses were performed while the operator was standing behind the subject, using both hands on the top of the subject’s head, well away from the goggles strap and forehead skin. Two calibrations were completed in each system, prior to beginning the test. Results: Test parameters were recorded through both systems for healthy subjects with no history or complaint of any vestibular disorder (N = 12; M/F = 5/7; age 35.1 ± 13.5 y) and for pathological subjects with a diagnosis of unilateral or bilateral vestibular disorder (N = 15; M/F = 7/8; age 53.4 ± 16.7 y). Conclusions: The vHIT is an important tool for otoneurological complementary evaluation. Both systems are reliable for vestibular disorders. The EyeSeeCam seems to reject fewer data and provides more information to include in diagnostics. Because of the small sample, there is a need for further in-depth comparison of both systems.Academia Brasileira de Neurologia - ABNEURO2021-07-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2021000700571Arquivos de Neuro-Psiquiatria v.79 n.7 2021reponame:Arquivos de neuro-psiquiatria (Online)instname:Academia Brasileira de Neurologiainstacron:ABNEURO10.1590/0004-282x-anp-2020-0301info:eu-repo/semantics/openAccessFelipe,Lilianeng2021-08-23T00:00:00Zoai:scielo:S0004-282X2021000700571Revistahttp://www.scielo.br/anphttps://old.scielo.br/oai/scielo-oai.php||revista.arquivos@abneuro.org1678-42270004-282Xopendoar:2021-08-23T00:00Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologiafalse |
dc.title.none.fl_str_mv |
Comparison of two systems for the video head impulse test (vHIT) for the lateral semicircular canal: description of results from normal and pathological subjects |
title |
Comparison of two systems for the video head impulse test (vHIT) for the lateral semicircular canal: description of results from normal and pathological subjects |
spellingShingle |
Comparison of two systems for the video head impulse test (vHIT) for the lateral semicircular canal: description of results from normal and pathological subjects Felipe,Lilian Diagnosis Head Impulse Test Postural Balance Semicircular Canals Vestibular Function Tests |
title_short |
Comparison of two systems for the video head impulse test (vHIT) for the lateral semicircular canal: description of results from normal and pathological subjects |
title_full |
Comparison of two systems for the video head impulse test (vHIT) for the lateral semicircular canal: description of results from normal and pathological subjects |
title_fullStr |
Comparison of two systems for the video head impulse test (vHIT) for the lateral semicircular canal: description of results from normal and pathological subjects |
title_full_unstemmed |
Comparison of two systems for the video head impulse test (vHIT) for the lateral semicircular canal: description of results from normal and pathological subjects |
title_sort |
Comparison of two systems for the video head impulse test (vHIT) for the lateral semicircular canal: description of results from normal and pathological subjects |
author |
Felipe,Lilian |
author_facet |
Felipe,Lilian |
author_role |
author |
dc.contributor.author.fl_str_mv |
Felipe,Lilian |
dc.subject.por.fl_str_mv |
Diagnosis Head Impulse Test Postural Balance Semicircular Canals Vestibular Function Tests |
topic |
Diagnosis Head Impulse Test Postural Balance Semicircular Canals Vestibular Function Tests |
description |
ABSTRACT Background: The video head impulse test (vHIT) is a recent technique for functional evaluation of semicircular canals (SSCs). The vHIT examines eye movements at high frequencies of stimulation and provides an objective assessment of the functioning of the high-frequency domain of the vestibular system. Objective: To describe the results from vHIT performed using two systems. Methods: All subjects were evaluated through an audiological and otoneurological battery of tests and were diagnosed as normal or abnormal by an otorhinolaryngologist. The results from two systems: 1. ICS Impulse (Otometrics/Natus, Denmark) and 2. EyeSeeCam (InterAcoustics, Denmark) were recorded. The same operator delivered every impulse to every subject. The head impulses were performed while the operator was standing behind the subject, using both hands on the top of the subject’s head, well away from the goggles strap and forehead skin. Two calibrations were completed in each system, prior to beginning the test. Results: Test parameters were recorded through both systems for healthy subjects with no history or complaint of any vestibular disorder (N = 12; M/F = 5/7; age 35.1 ± 13.5 y) and for pathological subjects with a diagnosis of unilateral or bilateral vestibular disorder (N = 15; M/F = 7/8; age 53.4 ± 16.7 y). Conclusions: The vHIT is an important tool for otoneurological complementary evaluation. Both systems are reliable for vestibular disorders. The EyeSeeCam seems to reject fewer data and provides more information to include in diagnostics. Because of the small sample, there is a need for further in-depth comparison of both systems. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-07-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2021000700571 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2021000700571 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0004-282x-anp-2020-0301 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Academia Brasileira de Neurologia - ABNEURO |
publisher.none.fl_str_mv |
Academia Brasileira de Neurologia - ABNEURO |
dc.source.none.fl_str_mv |
Arquivos de Neuro-Psiquiatria v.79 n.7 2021 reponame:Arquivos de neuro-psiquiatria (Online) instname:Academia Brasileira de Neurologia instacron:ABNEURO |
instname_str |
Academia Brasileira de Neurologia |
instacron_str |
ABNEURO |
institution |
ABNEURO |
reponame_str |
Arquivos de neuro-psiquiatria (Online) |
collection |
Arquivos de neuro-psiquiatria (Online) |
repository.name.fl_str_mv |
Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologia |
repository.mail.fl_str_mv |
||revista.arquivos@abneuro.org |
_version_ |
1754212789117779968 |