Noninvasive intracranial pressure monitoring methods: a critical review
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos de neuro-psiquiatria (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2021000500437 |
Resumo: | ABSTRACT Background: Intracranial pressure (ICP) monitoring has been used for decades in management of various neurological conditions. The gold standard for measuring ICP is a ventricular catheter connected to an external strain gauge, which is an invasive system associated with a number of complications. Despite its limitations, no noninvasive ICP monitoring (niICP) method fulfilling the technical requirements for replacing invasive techniques has yet been developed, not even in cases requiring only ICP monitoring without cerebrospinal fluid (CSF) drainage. Objectives: Here, we review the current methods for niICP monitoring. Methods: The different methods and approaches were grouped according to the mechanism used for detecting elevated ICP or its associated consequences. Results: The main approaches reviewed here were: physical examination, brain imaging (magnetic resonance imaging, computed tomography), indirect ICP estimation techniques (fundoscopy, tympanic membrane displacement, skull elasticity, optic nerve sheath ultrasound), cerebral blood flow evaluation (transcranial Doppler, ophthalmic artery Doppler), metabolic changes measurements (near-infrared spectroscopy) and neurophysiological studies (electroencephalogram, visual evoked potential, otoacoustic emissions). Conclusion: In terms of accuracy, reliability and therapeutic options, intraventricular catheter systems still remain the gold standard method. However, with advances in technology, noninvasive monitoring methods have become more relevant. Further evidence is needed before noninvasive methods for ICP monitoring or estimation become a more widespread alternative to invasive techniques. |
id |
ABNEURO-1_50e6a4e61d2b3cce659f5d5412278ca7 |
---|---|
oai_identifier_str |
oai:scielo:S0004-282X2021000500437 |
network_acronym_str |
ABNEURO-1 |
network_name_str |
Arquivos de neuro-psiquiatria (Online) |
repository_id_str |
|
spelling |
Noninvasive intracranial pressure monitoring methods: a critical reviewBrain InjuryIntracranial HypertensionStrokeIntracranial PressureHead TraumaABSTRACT Background: Intracranial pressure (ICP) monitoring has been used for decades in management of various neurological conditions. The gold standard for measuring ICP is a ventricular catheter connected to an external strain gauge, which is an invasive system associated with a number of complications. Despite its limitations, no noninvasive ICP monitoring (niICP) method fulfilling the technical requirements for replacing invasive techniques has yet been developed, not even in cases requiring only ICP monitoring without cerebrospinal fluid (CSF) drainage. Objectives: Here, we review the current methods for niICP monitoring. Methods: The different methods and approaches were grouped according to the mechanism used for detecting elevated ICP or its associated consequences. Results: The main approaches reviewed here were: physical examination, brain imaging (magnetic resonance imaging, computed tomography), indirect ICP estimation techniques (fundoscopy, tympanic membrane displacement, skull elasticity, optic nerve sheath ultrasound), cerebral blood flow evaluation (transcranial Doppler, ophthalmic artery Doppler), metabolic changes measurements (near-infrared spectroscopy) and neurophysiological studies (electroencephalogram, visual evoked potential, otoacoustic emissions). Conclusion: In terms of accuracy, reliability and therapeutic options, intraventricular catheter systems still remain the gold standard method. However, with advances in technology, noninvasive monitoring methods have become more relevant. Further evidence is needed before noninvasive methods for ICP monitoring or estimation become a more widespread alternative to invasive techniques.Academia Brasileira de Neurologia - ABNEURO2021-05-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2021000500437Arquivos de Neuro-Psiquiatria v.79 n.5 2021reponame:Arquivos de neuro-psiquiatria (Online)instname:Academia Brasileira de Neurologiainstacron:ABNEURO10.1590/0004-282x-anp-2020-0300info:eu-repo/semantics/openAccessMoraes,Fabiano Moulin deSilva,Gisele Sampaioeng2021-06-18T00:00:00Zoai:scielo:S0004-282X2021000500437Revistahttp://www.scielo.br/anphttps://old.scielo.br/oai/scielo-oai.php||revista.arquivos@abneuro.org1678-42270004-282Xopendoar:2021-06-18T00:00Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologiafalse |
dc.title.none.fl_str_mv |
Noninvasive intracranial pressure monitoring methods: a critical review |
title |
Noninvasive intracranial pressure monitoring methods: a critical review |
spellingShingle |
Noninvasive intracranial pressure monitoring methods: a critical review Moraes,Fabiano Moulin de Brain Injury Intracranial Hypertension Stroke Intracranial Pressure Head Trauma |
title_short |
Noninvasive intracranial pressure monitoring methods: a critical review |
title_full |
Noninvasive intracranial pressure monitoring methods: a critical review |
title_fullStr |
Noninvasive intracranial pressure monitoring methods: a critical review |
title_full_unstemmed |
Noninvasive intracranial pressure monitoring methods: a critical review |
title_sort |
Noninvasive intracranial pressure monitoring methods: a critical review |
author |
Moraes,Fabiano Moulin de |
author_facet |
Moraes,Fabiano Moulin de Silva,Gisele Sampaio |
author_role |
author |
author2 |
Silva,Gisele Sampaio |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Moraes,Fabiano Moulin de Silva,Gisele Sampaio |
dc.subject.por.fl_str_mv |
Brain Injury Intracranial Hypertension Stroke Intracranial Pressure Head Trauma |
topic |
Brain Injury Intracranial Hypertension Stroke Intracranial Pressure Head Trauma |
description |
ABSTRACT Background: Intracranial pressure (ICP) monitoring has been used for decades in management of various neurological conditions. The gold standard for measuring ICP is a ventricular catheter connected to an external strain gauge, which is an invasive system associated with a number of complications. Despite its limitations, no noninvasive ICP monitoring (niICP) method fulfilling the technical requirements for replacing invasive techniques has yet been developed, not even in cases requiring only ICP monitoring without cerebrospinal fluid (CSF) drainage. Objectives: Here, we review the current methods for niICP monitoring. Methods: The different methods and approaches were grouped according to the mechanism used for detecting elevated ICP or its associated consequences. Results: The main approaches reviewed here were: physical examination, brain imaging (magnetic resonance imaging, computed tomography), indirect ICP estimation techniques (fundoscopy, tympanic membrane displacement, skull elasticity, optic nerve sheath ultrasound), cerebral blood flow evaluation (transcranial Doppler, ophthalmic artery Doppler), metabolic changes measurements (near-infrared spectroscopy) and neurophysiological studies (electroencephalogram, visual evoked potential, otoacoustic emissions). Conclusion: In terms of accuracy, reliability and therapeutic options, intraventricular catheter systems still remain the gold standard method. However, with advances in technology, noninvasive monitoring methods have become more relevant. Further evidence is needed before noninvasive methods for ICP monitoring or estimation become a more widespread alternative to invasive techniques. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-05-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2021000500437 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2021000500437 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0004-282x-anp-2020-0300 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Academia Brasileira de Neurologia - ABNEURO |
publisher.none.fl_str_mv |
Academia Brasileira de Neurologia - ABNEURO |
dc.source.none.fl_str_mv |
Arquivos de Neuro-Psiquiatria v.79 n.5 2021 reponame:Arquivos de neuro-psiquiatria (Online) instname:Academia Brasileira de Neurologia instacron:ABNEURO |
instname_str |
Academia Brasileira de Neurologia |
instacron_str |
ABNEURO |
institution |
ABNEURO |
reponame_str |
Arquivos de neuro-psiquiatria (Online) |
collection |
Arquivos de neuro-psiquiatria (Online) |
repository.name.fl_str_mv |
Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologia |
repository.mail.fl_str_mv |
||revista.arquivos@abneuro.org |
_version_ |
1754212788571471872 |