Analysis of mean transcutaneous capnography in consecutive patients undergoing polysomnography

Detalhes bibliográficos
Autor(a) principal: Pinnola,Giulio Cesare
Data de Publicação: 2014
Outros Autores: Bastos,Patrícia Souza
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos de neuro-psiquiatria (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2014001100841
Resumo: Transcutaneous capnography is a noninvasive method useful for analysis of the behavioral tendency of transcutaneous CO2 pressure (PtcCO2) in patients undergoing polysomnography, to evaluate respiratory sleep disorders. Objective Determine normative PtcCO2 values in normal patients undergoing polysomnography. Method One hundred seventy-nine patients who underwent polysomnography with simultaneous PtcCO2 measurement were assessed by means of a transcutaneous capnograph (TCM4 series from Radiomiter). Results The group classified as normal (N=53) presented a apnea/hypopnea index (AHI) <5 events/per hour of sleep and their age groups varied between 7 and 76 years of age. Conclusion Global mean values of PtcCO2 in the normal group had a Gaussian distribution that varied between 33.1 and 50.0 mmHg (SD 4,363). Such findings allowed the establishment of normative PtcCO2 values for normal individuals.
id ABNEURO-1_a9fde7a51b4a1e4c277082f838e6edc8
oai_identifier_str oai:scielo:S0004-282X2014001100841
network_acronym_str ABNEURO-1
network_name_str Arquivos de neuro-psiquiatria (Online)
repository_id_str
spelling Analysis of mean transcutaneous capnography in consecutive patients undergoing polysomnographypolysomonographytranscutaneous capnographyCO2 pressureTranscutaneous capnography is a noninvasive method useful for analysis of the behavioral tendency of transcutaneous CO2 pressure (PtcCO2) in patients undergoing polysomnography, to evaluate respiratory sleep disorders. Objective Determine normative PtcCO2 values in normal patients undergoing polysomnography. Method One hundred seventy-nine patients who underwent polysomnography with simultaneous PtcCO2 measurement were assessed by means of a transcutaneous capnograph (TCM4 series from Radiomiter). Results The group classified as normal (N=53) presented a apnea/hypopnea index (AHI) <5 events/per hour of sleep and their age groups varied between 7 and 76 years of age. Conclusion Global mean values of PtcCO2 in the normal group had a Gaussian distribution that varied between 33.1 and 50.0 mmHg (SD 4,363). Such findings allowed the establishment of normative PtcCO2 values for normal individuals. Academia Brasileira de Neurologia - ABNEURO2014-11-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2014001100841Arquivos de Neuro-Psiquiatria v.72 n.11 2014reponame:Arquivos de neuro-psiquiatria (Online)instname:Academia Brasileira de Neurologiainstacron:ABNEURO10.1590/0004-282X20140138info:eu-repo/semantics/openAccessPinnola,Giulio CesareBastos,Patrícia Souzaeng2014-11-14T00:00:00Zoai:scielo:S0004-282X2014001100841Revistahttp://www.scielo.br/anphttps://old.scielo.br/oai/scielo-oai.php||revista.arquivos@abneuro.org1678-42270004-282Xopendoar:2014-11-14T00:00Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologiafalse
dc.title.none.fl_str_mv Analysis of mean transcutaneous capnography in consecutive patients undergoing polysomnography
title Analysis of mean transcutaneous capnography in consecutive patients undergoing polysomnography
spellingShingle Analysis of mean transcutaneous capnography in consecutive patients undergoing polysomnography
Pinnola,Giulio Cesare
polysomonography
transcutaneous capnography
CO2 pressure
title_short Analysis of mean transcutaneous capnography in consecutive patients undergoing polysomnography
title_full Analysis of mean transcutaneous capnography in consecutive patients undergoing polysomnography
title_fullStr Analysis of mean transcutaneous capnography in consecutive patients undergoing polysomnography
title_full_unstemmed Analysis of mean transcutaneous capnography in consecutive patients undergoing polysomnography
title_sort Analysis of mean transcutaneous capnography in consecutive patients undergoing polysomnography
author Pinnola,Giulio Cesare
author_facet Pinnola,Giulio Cesare
Bastos,Patrícia Souza
author_role author
author2 Bastos,Patrícia Souza
author2_role author
dc.contributor.author.fl_str_mv Pinnola,Giulio Cesare
Bastos,Patrícia Souza
dc.subject.por.fl_str_mv polysomonography
transcutaneous capnography
CO2 pressure
topic polysomonography
transcutaneous capnography
CO2 pressure
description Transcutaneous capnography is a noninvasive method useful for analysis of the behavioral tendency of transcutaneous CO2 pressure (PtcCO2) in patients undergoing polysomnography, to evaluate respiratory sleep disorders. Objective Determine normative PtcCO2 values in normal patients undergoing polysomnography. Method One hundred seventy-nine patients who underwent polysomnography with simultaneous PtcCO2 measurement were assessed by means of a transcutaneous capnograph (TCM4 series from Radiomiter). Results The group classified as normal (N=53) presented a apnea/hypopnea index (AHI) <5 events/per hour of sleep and their age groups varied between 7 and 76 years of age. Conclusion Global mean values of PtcCO2 in the normal group had a Gaussian distribution that varied between 33.1 and 50.0 mmHg (SD 4,363). Such findings allowed the establishment of normative PtcCO2 values for normal individuals.
publishDate 2014
dc.date.none.fl_str_mv 2014-11-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2014001100841
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X2014001100841
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0004-282X20140138
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Academia Brasileira de Neurologia - ABNEURO
publisher.none.fl_str_mv Academia Brasileira de Neurologia - ABNEURO
dc.source.none.fl_str_mv Arquivos de Neuro-Psiquiatria v.72 n.11 2014
reponame:Arquivos de neuro-psiquiatria (Online)
instname:Academia Brasileira de Neurologia
instacron:ABNEURO
instname_str Academia Brasileira de Neurologia
instacron_str ABNEURO
institution ABNEURO
reponame_str Arquivos de neuro-psiquiatria (Online)
collection Arquivos de neuro-psiquiatria (Online)
repository.name.fl_str_mv Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologia
repository.mail.fl_str_mv ||revista.arquivos@abneuro.org
_version_ 1754212777197568000