Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X1996000300005
Resumo: Twenty normal individuals were submitted to facial nerve electroneurography using different techniques in order to determine the most accurate to obtain the latencies and amplitudes of the compound muscle action potentials (CMAP) of the facial muscles. First of all it was determined in which muscle or muscle group highest amplitude CMAP could be recorded with the lowest variability between sides and in test-retest. Different techniques were studied in order to determine which could give the best results. This was shown to be an arrangement of bipolar surface electrodes fixed to a plastic bar. The records with higher amplitude where obtained from the nasolabial fold muscles. Therefore 65 normal volunteers were examined using this technique and recording the potentials obtained over the nasolabial fold muscles. Normal values were determined (latency lower than 4.5 ms and amplitude larger than 2 mV - 95% confidence limits).
id ABNEURO-1_adc1537a7c4fab455ea635e0f2196bbe
oai_identifier_str oai:scielo:S0004-282X1996000300005
network_acronym_str ABNEURO-1
network_name_str Arquivos de neuro-psiquiatria (Online)
repository_id_str
spelling Facial nerve electroneurography: variability in normal subjectsfacial nerveeletroneurographyTwenty normal individuals were submitted to facial nerve electroneurography using different techniques in order to determine the most accurate to obtain the latencies and amplitudes of the compound muscle action potentials (CMAP) of the facial muscles. First of all it was determined in which muscle or muscle group highest amplitude CMAP could be recorded with the lowest variability between sides and in test-retest. Different techniques were studied in order to determine which could give the best results. This was shown to be an arrangement of bipolar surface electrodes fixed to a plastic bar. The records with higher amplitude where obtained from the nasolabial fold muscles. Therefore 65 normal volunteers were examined using this technique and recording the potentials obtained over the nasolabial fold muscles. Normal values were determined (latency lower than 4.5 ms and amplitude larger than 2 mV - 95% confidence limits).Academia Brasileira de Neurologia - ABNEURO1996-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X1996000300005Arquivos de Neuro-Psiquiatria v.54 n.3 1996reponame:Arquivos de neuro-psiquiatria (Online)instname:Academia Brasileira de Neurologiainstacron:ABNEURO10.1590/S0004-282X1996000300005info:eu-repo/semantics/openAccessMedeiros,Jovany Luis Alves deNobrega,João Antonio MacielAndrade,Luiz Augusto Franco deJuliano,Yaraeng2010-11-10T00:00:00Zoai:scielo:S0004-282X1996000300005Revistahttp://www.scielo.br/anphttps://old.scielo.br/oai/scielo-oai.php||revista.arquivos@abneuro.org1678-42270004-282Xopendoar:2010-11-10T00:00Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologiafalse
dc.title.none.fl_str_mv Facial nerve electroneurography: variability in normal subjects
title Facial nerve electroneurography: variability in normal subjects
spellingShingle Facial nerve electroneurography: variability in normal subjects
Medeiros,Jovany Luis Alves de
facial nerve
eletroneurography
title_short Facial nerve electroneurography: variability in normal subjects
title_full Facial nerve electroneurography: variability in normal subjects
title_fullStr Facial nerve electroneurography: variability in normal subjects
title_full_unstemmed Facial nerve electroneurography: variability in normal subjects
title_sort Facial nerve electroneurography: variability in normal subjects
author Medeiros,Jovany Luis Alves de
author_facet Medeiros,Jovany Luis Alves de
Nobrega,João Antonio Maciel
Andrade,Luiz Augusto Franco de
Juliano,Yara
author_role author
author2 Nobrega,João Antonio Maciel
Andrade,Luiz Augusto Franco de
Juliano,Yara
author2_role author
author
author
dc.contributor.author.fl_str_mv Medeiros,Jovany Luis Alves de
Nobrega,João Antonio Maciel
Andrade,Luiz Augusto Franco de
Juliano,Yara
dc.subject.por.fl_str_mv facial nerve
eletroneurography
topic facial nerve
eletroneurography
description Twenty normal individuals were submitted to facial nerve electroneurography using different techniques in order to determine the most accurate to obtain the latencies and amplitudes of the compound muscle action potentials (CMAP) of the facial muscles. First of all it was determined in which muscle or muscle group highest amplitude CMAP could be recorded with the lowest variability between sides and in test-retest. Different techniques were studied in order to determine which could give the best results. This was shown to be an arrangement of bipolar surface electrodes fixed to a plastic bar. The records with higher amplitude where obtained from the nasolabial fold muscles. Therefore 65 normal volunteers were examined using this technique and recording the potentials obtained over the nasolabial fold muscles. Normal values were determined (latency lower than 4.5 ms and amplitude larger than 2 mV - 95% confidence limits).
publishDate 1996
dc.date.none.fl_str_mv 1996-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X1996000300005
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-282X1996000300005
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0004-282X1996000300005
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Academia Brasileira de Neurologia - ABNEURO
publisher.none.fl_str_mv Academia Brasileira de Neurologia - ABNEURO
dc.source.none.fl_str_mv Arquivos de Neuro-Psiquiatria v.54 n.3 1996
reponame:Arquivos de neuro-psiquiatria (Online)
instname:Academia Brasileira de Neurologia
instacron:ABNEURO
instname_str Academia Brasileira de Neurologia
instacron_str ABNEURO
institution ABNEURO
reponame_str Arquivos de neuro-psiquiatria (Online)
collection Arquivos de neuro-psiquiatria (Online)
repository.name.fl_str_mv Arquivos de neuro-psiquiatria (Online) - Academia Brasileira de Neurologia
repository.mail.fl_str_mv ||revista.arquivos@abneuro.org
_version_ 1754212749891600384