Influence of photoactivation with halogen light and LED and types of activation on degree of conversion of two composites

Detalhes bibliográficos
Autor(a) principal: Ritto, Fernanda Pitta
Data de Publicação: 2011
Outros Autores: Borges, Márcio Antônio Paraízo, Bastian, Fernando Luiz, Michelon, Marcela Mendes Medeiros, Matos, Irma Cunha
Tipo de documento: Artigo
Idioma: por
Título da fonte: Revista Brasileira de Odontologia
Texto Completo: https://revista.aborj.org.br/index.php/rbo/article/view/197
Resumo: The objective this paper is evaluate influence of photoativation with halogen light and LED on conversion’s degree of two different composites. Thirty samples were divided in six groups considering type of composite, photoativation unit and type of polimerization used. Raman spectrophotometry was used to measure the degree of conversion. The Non-polimerized and polimerized samples were compared to evaluate if there was any difference on the degree of conversion to Ho1: composites; Ho2: diferent polimerization sources and Ho3: diferent activation modes. Anova and T Student were utlilized to statistical analysis. Results showed difference between the degrees of conversion of the different composites expressing a higher value for nanoparticulate resins, which could be explained by the presence of the TEGDMA on the composition of the matrix.
id ABO-1_41470d526328db09dd3360a1d1d6c241
oai_identifier_str oai:revista_aborj_org_br.www.revista.aborj.org.br:article/197
network_acronym_str ABO-1
network_name_str Revista Brasileira de Odontologia
repository_id_str
spelling Influence of photoactivation with halogen light and LED and types of activation on degree of conversion of two compositesInfluência das fontes halógena e LED e modos de ativação no grau de conversão de dois compósitosResinas compostas; Raman; Grau de conversãoThe objective this paper is evaluate influence of photoativation with halogen light and LED on conversion’s degree of two different composites. Thirty samples were divided in six groups considering type of composite, photoativation unit and type of polimerization used. Raman spectrophotometry was used to measure the degree of conversion. The Non-polimerized and polimerized samples were compared to evaluate if there was any difference on the degree of conversion to Ho1: composites; Ho2: diferent polimerization sources and Ho3: diferent activation modes. Anova and T Student were utlilized to statistical analysis. Results showed difference between the degrees of conversion of the different composites expressing a higher value for nanoparticulate resins, which could be explained by the presence of the TEGDMA on the composition of the matrix.O objetivo do presente artigo é avaliar a influência da fotoativação com lâmpadas halógena e LED no grau de conversão dos compósitos microíbrido e nanoparticulado. Trinta amostras foram divididas em seis grupos variando tipo de resina, tipo de lâmpada e tipo de ativação. Para medir grau de conversão foi utilizada espectrofotometria por Raman. As amostras não polimerizadas e polimerizadas foram comparadas para avaliar se houve diferença no grau de conversão para Ho1: os diferentes compósitos; Ho2: as diferentes fontes luminosas e Ho3: os diferentes modos de ativação. Para análise estatística foram utilizados Anova e T de Student. Os resultados mostraram haver diferença estatística, demonstrando maior grau de conversão para resinas nanoparticuladas, o que pode estar ligado à presença de TEGDMA em sua matriz.Associação Brasileira de Odontologia - Seção Rio de Janeiro2011-02-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPesquisa Descritivaapplication/pdfhttps://revista.aborj.org.br/index.php/rbo/article/view/19710.18363/rbo.v67n2.p.220Revista Brasileira de Odontologia; v. 67, n. 2 (2010); 220Revista Brasileira de Odontologia; v. 67, n. 2 (2010); 2201984-3747reponame:Revista Brasileira de Odontologiainstname:Associação Brasileira de Odontologia (ABO)instacron:ABOporhttps://revista.aborj.org.br/index.php/rbo/article/view/197/193Direitos autorais 2016 Revistasinfo:eu-repo/semantics/openAccessRitto, Fernanda PittaBorges, Márcio Antônio ParaízoBastian, Fernando LuizMichelon, Marcela Mendes MedeirosMatos, Irma Cunha2011-02-09T13:26:47Zoai:revista_aborj_org_br.www.revista.aborj.org.br:article/197Revistahttps://revista.aborj.org.br/index.php/rboONGhttp://www.revista.aborj.org.br/index.php/rbo/oaihttps://revista.aborj.org.br/index.php/rbo/oai0034-72721984-3747opendoar:2011-02-09T13:26:47Revista Brasileira de Odontologia - Associação Brasileira de Odontologia (ABO)false
dc.title.none.fl_str_mv Influence of photoactivation with halogen light and LED and types of activation on degree of conversion of two composites
Influência das fontes halógena e LED e modos de ativação no grau de conversão de dois compósitos
title Influence of photoactivation with halogen light and LED and types of activation on degree of conversion of two composites
spellingShingle Influence of photoactivation with halogen light and LED and types of activation on degree of conversion of two composites
Ritto, Fernanda Pitta
Resinas compostas; Raman; Grau de conversão
title_short Influence of photoactivation with halogen light and LED and types of activation on degree of conversion of two composites
title_full Influence of photoactivation with halogen light and LED and types of activation on degree of conversion of two composites
title_fullStr Influence of photoactivation with halogen light and LED and types of activation on degree of conversion of two composites
title_full_unstemmed Influence of photoactivation with halogen light and LED and types of activation on degree of conversion of two composites
title_sort Influence of photoactivation with halogen light and LED and types of activation on degree of conversion of two composites
author Ritto, Fernanda Pitta
author_facet Ritto, Fernanda Pitta
Borges, Márcio Antônio Paraízo
Bastian, Fernando Luiz
Michelon, Marcela Mendes Medeiros
Matos, Irma Cunha
author_role author
author2 Borges, Márcio Antônio Paraízo
Bastian, Fernando Luiz
Michelon, Marcela Mendes Medeiros
Matos, Irma Cunha
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Ritto, Fernanda Pitta
Borges, Márcio Antônio Paraízo
Bastian, Fernando Luiz
Michelon, Marcela Mendes Medeiros
Matos, Irma Cunha
dc.subject.por.fl_str_mv Resinas compostas; Raman; Grau de conversão
topic Resinas compostas; Raman; Grau de conversão
description The objective this paper is evaluate influence of photoativation with halogen light and LED on conversion’s degree of two different composites. Thirty samples were divided in six groups considering type of composite, photoativation unit and type of polimerization used. Raman spectrophotometry was used to measure the degree of conversion. The Non-polimerized and polimerized samples were compared to evaluate if there was any difference on the degree of conversion to Ho1: composites; Ho2: diferent polimerization sources and Ho3: diferent activation modes. Anova and T Student were utlilized to statistical analysis. Results showed difference between the degrees of conversion of the different composites expressing a higher value for nanoparticulate resins, which could be explained by the presence of the TEGDMA on the composition of the matrix.
publishDate 2011
dc.date.none.fl_str_mv 2011-02-08
dc.type.none.fl_str_mv

dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Pesquisa Descritiva
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revista.aborj.org.br/index.php/rbo/article/view/197
10.18363/rbo.v67n2.p.220
url https://revista.aborj.org.br/index.php/rbo/article/view/197
identifier_str_mv 10.18363/rbo.v67n2.p.220
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://revista.aborj.org.br/index.php/rbo/article/view/197/193
dc.rights.driver.fl_str_mv Direitos autorais 2016 Revistas
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Direitos autorais 2016 Revistas
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Associação Brasileira de Odontologia - Seção Rio de Janeiro
publisher.none.fl_str_mv Associação Brasileira de Odontologia - Seção Rio de Janeiro
dc.source.none.fl_str_mv Revista Brasileira de Odontologia; v. 67, n. 2 (2010); 220
Revista Brasileira de Odontologia; v. 67, n. 2 (2010); 220
1984-3747
reponame:Revista Brasileira de Odontologia
instname:Associação Brasileira de Odontologia (ABO)
instacron:ABO
instname_str Associação Brasileira de Odontologia (ABO)
instacron_str ABO
institution ABO
reponame_str Revista Brasileira de Odontologia
collection Revista Brasileira de Odontologia
repository.name.fl_str_mv Revista Brasileira de Odontologia - Associação Brasileira de Odontologia (ABO)
repository.mail.fl_str_mv https://revista.aborj.org.br/index.php/rbo/oai
_version_ 1798313202722799616