Quality of three ionomers cements used in public health service: an in vitro study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Revista Brasileira de Odontologia |
Texto Completo: | https://revista.aborj.org.br/index.php/rbo/article/view/530 |
Resumo: | The diametric tensile strength (DT) is a prerequisite for clinical success of restoration. Thus, this study aimed to evaluate the resistance of DT of three types of glass ionomer cements (IO) for restorative, and compare with a composite resin. Eight samples of each material were using by bipartite matrices. All of the materials were used according to manufacturers. The DT test was performed using a universal testing machine with a load of 200 kgf. The results were analyzed using Anova and Turkey (p |
id |
ABO-1_57db442f185d709fdf24450619f56276 |
---|---|
oai_identifier_str |
oai:revista_aborj_org_br.www.revista.aborj.org.br:article/530 |
network_acronym_str |
ABO-1 |
network_name_str |
Revista Brasileira de Odontologia |
repository_id_str |
|
spelling |
Quality of three ionomers cements used in public health service: an in vitro studyQualidade de três tipos de cimentos de ionômeros de vidro utilizados em postos de saúde pública: um estudo in vitroMedicina Dentária (Odontologia)materiais dentários, cimento ionômero de vidro, resina composta, resistência à tração diametralMateriais DentáriosThe diametric tensile strength (DT) is a prerequisite for clinical success of restoration. Thus, this study aimed to evaluate the resistance of DT of three types of glass ionomer cements (IO) for restorative, and compare with a composite resin. Eight samples of each material were using by bipartite matrices. All of the materials were used according to manufacturers. The DT test was performed using a universal testing machine with a load of 200 kgf. The results were analyzed using Anova and Turkey (p A resistência à tração diametral (TD) é um requisito essencial para o sucesso clínico das restaurações. Dessa forma, este estudo objetivou avaliar a resistência à TD de três tipos cimentos ionômero de vidro (CIV) em comparação com uma resina composta, todos utilizados em seis postos de saúde pública do município de Duque de Caxias/RJ. O TD foi realizado em uma máquina universal com uma célula de carga de 200 Kgf. Os valores médios de resistência à TD, em MPa, foram: 11,46 (CIV A), 10 (CIV B), 31 (CIVC) e 38,13 (Resina). Os resultados foram analisados pelos testes Anova e Turkey (p < 0,05). Concluiu-se que os CIVs apresentaram resistência à TD semelhante entre eles, porém inferior à resina, mas ainda sendo uma ótima opção para restauração preconizada pelo Serviço Público de Saúde (SUS).Associação Brasileira de Odontologia - Seção Rio de Janeiro2015-05-27info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPesquisa Laboratorial experimentalapplication/pdfhttps://revista.aborj.org.br/index.php/rbo/article/view/53010.18363/rbo.v71n2.p.135Revista Brasileira de Odontologia; v. 71, n. 2 (2014); 135Revista Brasileira de Odontologia; v. 71, n. 2 (2014); 1351984-3747reponame:Revista Brasileira de Odontologiainstname:Associação Brasileira de Odontologia (ABO)instacron:ABOporhttps://revista.aborj.org.br/index.php/rbo/article/view/530/424Rio de Janeiro; Brasil; América LatinaAtualidadeestudo in vitro, laboratorialDireitos autorais 2016 Revistasinfo:eu-repo/semantics/openAccessPedro, Rafael LimaGalhardi, Michelle Paiva WeydtMotta, Luise GomesCosta, Marcelo Castro2016-02-12T12:07:24Zoai:revista_aborj_org_br.www.revista.aborj.org.br:article/530Revistahttps://revista.aborj.org.br/index.php/rboONGhttp://www.revista.aborj.org.br/index.php/rbo/oaihttps://revista.aborj.org.br/index.php/rbo/oai0034-72721984-3747opendoar:2016-02-12T12:07:24Revista Brasileira de Odontologia - Associação Brasileira de Odontologia (ABO)false |
dc.title.none.fl_str_mv |
Quality of three ionomers cements used in public health service: an in vitro study Qualidade de três tipos de cimentos de ionômeros de vidro utilizados em postos de saúde pública: um estudo in vitro |
title |
Quality of three ionomers cements used in public health service: an in vitro study |
spellingShingle |
Quality of three ionomers cements used in public health service: an in vitro study Pedro, Rafael Lima Medicina Dentária (Odontologia) materiais dentários, cimento ionômero de vidro, resina composta, resistência à tração diametral Materiais Dentários |
title_short |
Quality of three ionomers cements used in public health service: an in vitro study |
title_full |
Quality of three ionomers cements used in public health service: an in vitro study |
title_fullStr |
Quality of three ionomers cements used in public health service: an in vitro study |
title_full_unstemmed |
Quality of three ionomers cements used in public health service: an in vitro study |
title_sort |
Quality of three ionomers cements used in public health service: an in vitro study |
author |
Pedro, Rafael Lima |
author_facet |
Pedro, Rafael Lima Galhardi, Michelle Paiva Weydt Motta, Luise Gomes Costa, Marcelo Castro |
author_role |
author |
author2 |
Galhardi, Michelle Paiva Weydt Motta, Luise Gomes Costa, Marcelo Castro |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Pedro, Rafael Lima Galhardi, Michelle Paiva Weydt Motta, Luise Gomes Costa, Marcelo Castro |
dc.subject.por.fl_str_mv |
Medicina Dentária (Odontologia) materiais dentários, cimento ionômero de vidro, resina composta, resistência à tração diametral Materiais Dentários |
topic |
Medicina Dentária (Odontologia) materiais dentários, cimento ionômero de vidro, resina composta, resistência à tração diametral Materiais Dentários |
description |
The diametric tensile strength (DT) is a prerequisite for clinical success of restoration. Thus, this study aimed to evaluate the resistance of DT of three types of glass ionomer cements (IO) for restorative, and compare with a composite resin. Eight samples of each material were using by bipartite matrices. All of the materials were used according to manufacturers. The DT test was performed using a universal testing machine with a load of 200 kgf. The results were analyzed using Anova and Turkey (p |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-05-27 |
dc.type.none.fl_str_mv |
|
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Pesquisa Laboratorial experimental |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revista.aborj.org.br/index.php/rbo/article/view/530 10.18363/rbo.v71n2.p.135 |
url |
https://revista.aborj.org.br/index.php/rbo/article/view/530 |
identifier_str_mv |
10.18363/rbo.v71n2.p.135 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://revista.aborj.org.br/index.php/rbo/article/view/530/424 |
dc.rights.driver.fl_str_mv |
Direitos autorais 2016 Revistas info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Direitos autorais 2016 Revistas |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.coverage.none.fl_str_mv |
Rio de Janeiro; Brasil; América Latina Atualidade estudo in vitro, laboratorial |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Odontologia - Seção Rio de Janeiro |
publisher.none.fl_str_mv |
Associação Brasileira de Odontologia - Seção Rio de Janeiro |
dc.source.none.fl_str_mv |
Revista Brasileira de Odontologia; v. 71, n. 2 (2014); 135 Revista Brasileira de Odontologia; v. 71, n. 2 (2014); 135 1984-3747 reponame:Revista Brasileira de Odontologia instname:Associação Brasileira de Odontologia (ABO) instacron:ABO |
instname_str |
Associação Brasileira de Odontologia (ABO) |
instacron_str |
ABO |
institution |
ABO |
reponame_str |
Revista Brasileira de Odontologia |
collection |
Revista Brasileira de Odontologia |
repository.name.fl_str_mv |
Revista Brasileira de Odontologia - Associação Brasileira de Odontologia (ABO) |
repository.mail.fl_str_mv |
https://revista.aborj.org.br/index.php/rbo/oai |
_version_ |
1798313204298809344 |