The influence of taper on rotatory endodontic NiTi instruments related to torsion failure
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Revista Brasileira de Odontologia |
Texto Completo: | https://revista.aborj.org.br/index.php/rbo/article/view/199 |
Resumo: | The aim of this work was to compare the angular deflection at failure and the maximum torque of NiTi rotatory instruments with the same size, same trademark and different tapers. The instruments were submitted to clockwise torsional mechanical tests. The values were submitted to statistical analisys and the results showed that the taper of helical shaft influenced the angular deflection and the maximum torque at failure. The angular deflection increased with the taper reduction, although the maximum torque at failure decreased with the taper reduction. |
id |
ABO-1_5a83c39a4cf98444df72c19c01de3a74 |
---|---|
oai_identifier_str |
oai:revista_aborj_org_br.www.revista.aborj.org.br:article/199 |
network_acronym_str |
ABO-1 |
network_name_str |
Revista Brasileira de Odontologia |
repository_id_str |
|
spelling |
The influence of taper on rotatory endodontic NiTi instruments related to torsion failureInfluência da conicidade de instrumentos endodônticos de NiTi mecanizados na falhaMedicina DentáriaFratura por torção; Deflexão angular; Torque máximoThe aim of this work was to compare the angular deflection at failure and the maximum torque of NiTi rotatory instruments with the same size, same trademark and different tapers. The instruments were submitted to clockwise torsional mechanical tests. The values were submitted to statistical analisys and the results showed that the taper of helical shaft influenced the angular deflection and the maximum torque at failure. The angular deflection increased with the taper reduction, although the maximum torque at failure decreased with the taper reduction.O objetivo deste trabalho foi comparar a deflexão angular até a fratura e o torque máximo em torção de instrumentos endodônticos de NiTi mecanizados de um mesmo número, de um mesmo fabricante de diferentes conicidades. Os instrumentos foram submetidos ao ensaio mecânico de torção à direita. Os valores obtidos foram submetidos à análise estatística e os resultados revelaram que a conicidade das hastes helicoidais dos instrumentos ensaiados influenciaram na deflexão angular até a fratura e no torque máximo suportado pelo instrumento antes da fratura. A deflexão angular aumentou com a redução da conicidade, enquanto o torque máximo diminuiu com a redução destaAssociação Brasileira de Odontologia - Seção Rio de Janeiro2011-02-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPesquisa Comparativaapplication/pdfhttps://revista.aborj.org.br/index.php/rbo/article/view/19910.18363/rbo.v67n2.p.233Revista Brasileira de Odontologia; v. 67, n. 2 (2010); 233Revista Brasileira de Odontologia; v. 67, n. 2 (2010); 2331984-3747reponame:Revista Brasileira de Odontologiainstname:Associação Brasileira de Odontologia (ABO)instacron:ABOporhttps://revista.aborj.org.br/index.php/rbo/article/view/199/195Direitos autorais 2016 Revistasinfo:eu-repo/semantics/openAccessLopes, Hélio PereiraElias, Carlos NelsonPrado, Marco Aurélio R.Batista, Marcelo Mangelli D.Vieira, Márcia Valéria B.Silveira, Adriana Maria VieiraFidel, Rivail Antônio Sérgio2011-02-09T13:26:47Zoai:revista_aborj_org_br.www.revista.aborj.org.br:article/199Revistahttps://revista.aborj.org.br/index.php/rboONGhttp://www.revista.aborj.org.br/index.php/rbo/oaihttps://revista.aborj.org.br/index.php/rbo/oai0034-72721984-3747opendoar:2011-02-09T13:26:47Revista Brasileira de Odontologia - Associação Brasileira de Odontologia (ABO)false |
dc.title.none.fl_str_mv |
The influence of taper on rotatory endodontic NiTi instruments related to torsion failure Influência da conicidade de instrumentos endodônticos de NiTi mecanizados na falha |
title |
The influence of taper on rotatory endodontic NiTi instruments related to torsion failure |
spellingShingle |
The influence of taper on rotatory endodontic NiTi instruments related to torsion failure Lopes, Hélio Pereira Medicina Dentária Fratura por torção; Deflexão angular; Torque máximo |
title_short |
The influence of taper on rotatory endodontic NiTi instruments related to torsion failure |
title_full |
The influence of taper on rotatory endodontic NiTi instruments related to torsion failure |
title_fullStr |
The influence of taper on rotatory endodontic NiTi instruments related to torsion failure |
title_full_unstemmed |
The influence of taper on rotatory endodontic NiTi instruments related to torsion failure |
title_sort |
The influence of taper on rotatory endodontic NiTi instruments related to torsion failure |
author |
Lopes, Hélio Pereira |
author_facet |
Lopes, Hélio Pereira Elias, Carlos Nelson Prado, Marco Aurélio R. Batista, Marcelo Mangelli D. Vieira, Márcia Valéria B. Silveira, Adriana Maria Vieira Fidel, Rivail Antônio Sérgio |
author_role |
author |
author2 |
Elias, Carlos Nelson Prado, Marco Aurélio R. Batista, Marcelo Mangelli D. Vieira, Márcia Valéria B. Silveira, Adriana Maria Vieira Fidel, Rivail Antônio Sérgio |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Lopes, Hélio Pereira Elias, Carlos Nelson Prado, Marco Aurélio R. Batista, Marcelo Mangelli D. Vieira, Márcia Valéria B. Silveira, Adriana Maria Vieira Fidel, Rivail Antônio Sérgio |
dc.subject.por.fl_str_mv |
Medicina Dentária Fratura por torção; Deflexão angular; Torque máximo |
topic |
Medicina Dentária Fratura por torção; Deflexão angular; Torque máximo |
description |
The aim of this work was to compare the angular deflection at failure and the maximum torque of NiTi rotatory instruments with the same size, same trademark and different tapers. The instruments were submitted to clockwise torsional mechanical tests. The values were submitted to statistical analisys and the results showed that the taper of helical shaft influenced the angular deflection and the maximum torque at failure. The angular deflection increased with the taper reduction, although the maximum torque at failure decreased with the taper reduction. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-02-08 |
dc.type.none.fl_str_mv |
|
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Pesquisa Comparativa |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revista.aborj.org.br/index.php/rbo/article/view/199 10.18363/rbo.v67n2.p.233 |
url |
https://revista.aborj.org.br/index.php/rbo/article/view/199 |
identifier_str_mv |
10.18363/rbo.v67n2.p.233 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://revista.aborj.org.br/index.php/rbo/article/view/199/195 |
dc.rights.driver.fl_str_mv |
Direitos autorais 2016 Revistas info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Direitos autorais 2016 Revistas |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Odontologia - Seção Rio de Janeiro |
publisher.none.fl_str_mv |
Associação Brasileira de Odontologia - Seção Rio de Janeiro |
dc.source.none.fl_str_mv |
Revista Brasileira de Odontologia; v. 67, n. 2 (2010); 233 Revista Brasileira de Odontologia; v. 67, n. 2 (2010); 233 1984-3747 reponame:Revista Brasileira de Odontologia instname:Associação Brasileira de Odontologia (ABO) instacron:ABO |
instname_str |
Associação Brasileira de Odontologia (ABO) |
instacron_str |
ABO |
institution |
ABO |
reponame_str |
Revista Brasileira de Odontologia |
collection |
Revista Brasileira de Odontologia |
repository.name.fl_str_mv |
Revista Brasileira de Odontologia - Associação Brasileira de Odontologia (ABO) |
repository.mail.fl_str_mv |
https://revista.aborj.org.br/index.php/rbo/oai |
_version_ |
1798313203861553152 |