Dental implant with bioactive surface
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Revista Brasileira de Odontologia |
Texto Completo: | https://revista.aborj.org.br/index.php/rbo/article/view/62 |
Resumo: | Although manufacturers of dental implants use the same titanium alloys, there is a difference in performance among commercial implants. This is due to the manufacturer procedures, mainly in the implant surface treatment. This work compares the roughness, wettability and removal torque from rabbit tibias and surface morphology of Ti dental implants as machined, acid-etched, treated with fluoride and anodized. The results showed that: i) the surface treatment increases the removal torque, ii) there is no statistical difference in the surface roughness and wettability among treated implants, iii) after anodizing treatment hydrophilic property increases and iv) after surface treatment the oxides on the implants surface show different chemical compositions and crystal structures. |
id |
ABO-1_62cc79eb93ab0b1f38c69f6758915932 |
---|---|
oai_identifier_str |
oai:revista_aborj_org_br.www.revista.aborj.org.br:article/62 |
network_acronym_str |
ABO-1 |
network_name_str |
Revista Brasileira de Odontologia |
repository_id_str |
|
spelling |
Dental implant with bioactive surfaceCaracterização e torque de remoção de implantes dentários com superfície bioativaMedicina Dentária (Odontologia)implante dentário; superfície anodizada; XPS; rugosidade.Although manufacturers of dental implants use the same titanium alloys, there is a difference in performance among commercial implants. This is due to the manufacturer procedures, mainly in the implant surface treatment. This work compares the roughness, wettability and removal torque from rabbit tibias and surface morphology of Ti dental implants as machined, acid-etched, treated with fluoride and anodized. The results showed that: i) the surface treatment increases the removal torque, ii) there is no statistical difference in the surface roughness and wettability among treated implants, iii) after anodizing treatment hydrophilic property increases and iv) after surface treatment the oxides on the implants surface show different chemical compositions and crystal structures.Apesar das empresas fabricantes dos implantes dentários osseointegráveis empregarem as mesmas ligas de titânio, existe diferença no desempenho entre os implantes comerciais. Este comportamento é associado aos procedimentos adotados durante a fabricação dos implantes, principalmente no tratamento da superfície. No presente trabalho, fez-se a comparação da rugosidade, molhabilidade, morfologia da superfície e torque de remoção da tíbia de coelhos de implantes de Ti usinados, tratados com ácido, tratados com flúor e anodizados. Os resultados obtidos mostraram que: i) o tratamento da superfície aumenta significativamente o torque de remoção, ii) não há diferença estatística significativa entre a rugosidade dos implantes tratados, iii) após a anodização, há aumento na propriedade hidrofílica do implante e, iv) após o tratamento da superfície, os implantes apresentam óxidos com diferentes composições químicas e estruturas cristalinas.Associação Brasileira de Odontologia - Seção Rio de Janeiro2009-01-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revista.aborj.org.br/index.php/rbo/article/view/6210.18363/rbo.v65n2.p.273Revista Brasileira de Odontologia; v. 65, n. 2 (2008); 273Revista Brasileira de Odontologia; v. 65, n. 2 (2008); 2731984-3747reponame:Revista Brasileira de Odontologiainstname:Associação Brasileira de Odontologia (ABO)instacron:ABOporhttps://revista.aborj.org.br/index.php/rbo/article/view/62/66Direitos autorais 2016 Revistasinfo:eu-repo/semantics/openAccessElias, CarlosBusquim, ThaisLima, José HenriqueMuller, Carlos Alberto2009-01-08T13:59:49Zoai:revista_aborj_org_br.www.revista.aborj.org.br:article/62Revistahttps://revista.aborj.org.br/index.php/rboONGhttp://www.revista.aborj.org.br/index.php/rbo/oaihttps://revista.aborj.org.br/index.php/rbo/oai0034-72721984-3747opendoar:2009-01-08T13:59:49Revista Brasileira de Odontologia - Associação Brasileira de Odontologia (ABO)false |
dc.title.none.fl_str_mv |
Dental implant with bioactive surface Caracterização e torque de remoção de implantes dentários com superfície bioativa |
title |
Dental implant with bioactive surface |
spellingShingle |
Dental implant with bioactive surface Elias, Carlos Medicina Dentária (Odontologia) implante dentário; superfície anodizada; XPS; rugosidade. |
title_short |
Dental implant with bioactive surface |
title_full |
Dental implant with bioactive surface |
title_fullStr |
Dental implant with bioactive surface |
title_full_unstemmed |
Dental implant with bioactive surface |
title_sort |
Dental implant with bioactive surface |
author |
Elias, Carlos |
author_facet |
Elias, Carlos Busquim, Thais Lima, José Henrique Muller, Carlos Alberto |
author_role |
author |
author2 |
Busquim, Thais Lima, José Henrique Muller, Carlos Alberto |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Elias, Carlos Busquim, Thais Lima, José Henrique Muller, Carlos Alberto |
dc.subject.por.fl_str_mv |
Medicina Dentária (Odontologia) implante dentário; superfície anodizada; XPS; rugosidade. |
topic |
Medicina Dentária (Odontologia) implante dentário; superfície anodizada; XPS; rugosidade. |
description |
Although manufacturers of dental implants use the same titanium alloys, there is a difference in performance among commercial implants. This is due to the manufacturer procedures, mainly in the implant surface treatment. This work compares the roughness, wettability and removal torque from rabbit tibias and surface morphology of Ti dental implants as machined, acid-etched, treated with fluoride and anodized. The results showed that: i) the surface treatment increases the removal torque, ii) there is no statistical difference in the surface roughness and wettability among treated implants, iii) after anodizing treatment hydrophilic property increases and iv) after surface treatment the oxides on the implants surface show different chemical compositions and crystal structures. |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-01-08 |
dc.type.none.fl_str_mv |
|
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revista.aborj.org.br/index.php/rbo/article/view/62 10.18363/rbo.v65n2.p.273 |
url |
https://revista.aborj.org.br/index.php/rbo/article/view/62 |
identifier_str_mv |
10.18363/rbo.v65n2.p.273 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://revista.aborj.org.br/index.php/rbo/article/view/62/66 |
dc.rights.driver.fl_str_mv |
Direitos autorais 2016 Revistas info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Direitos autorais 2016 Revistas |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Odontologia - Seção Rio de Janeiro |
publisher.none.fl_str_mv |
Associação Brasileira de Odontologia - Seção Rio de Janeiro |
dc.source.none.fl_str_mv |
Revista Brasileira de Odontologia; v. 65, n. 2 (2008); 273 Revista Brasileira de Odontologia; v. 65, n. 2 (2008); 273 1984-3747 reponame:Revista Brasileira de Odontologia instname:Associação Brasileira de Odontologia (ABO) instacron:ABO |
instname_str |
Associação Brasileira de Odontologia (ABO) |
instacron_str |
ABO |
institution |
ABO |
reponame_str |
Revista Brasileira de Odontologia |
collection |
Revista Brasileira de Odontologia |
repository.name.fl_str_mv |
Revista Brasileira de Odontologia - Associação Brasileira de Odontologia (ABO) |
repository.mail.fl_str_mv |
https://revista.aborj.org.br/index.php/rbo/oai |
_version_ |
1798313200733650944 |