Resumo: | ABSTRACT INTRODUCTION: One of the problems observed in pure-tone audiometry tonal has been the variation in test results of a same individual, particularly at frequencies of 4 kHz, 6 kHz and/or 8 kHz. Improper placement of headphones is one of the factors that can cause alterations in results. OBJECTIVE: To compare differences in auditory thresholds using earphones positioned by the examiner and by the worker. METHODS: Clinical and experimental study conducted in 2009, with 324 workers aged between 19 and 61 years, with a mean of 33.29 years and mean exposure time of 7.67 years. All subjects were familiar with audiometry procedures. Auditory thresholds were obtained at frequencies of 0.25-8 kHz, with earphones positioned by the examiners, and at frequencies of 4, 6 and 8 kHz, with earphones placed by workers in a comfortable position, following the examiner's instructions. The thresholds obtained in these two situations were compared. RESULTS: The three frequencies exhibited better responses with earphones placed by the workers themselves (p < 0.001). At a frequency of 8 kHz a greater difference was found (p < 0.001), with a mean of 13.89 dB and standard deviation of 6.07 dB. CONCLUSION: Earphone placement by the workers themselves under supervision of the examiner results in improved mean auditory thresholds at frequencies of 4, 6 and 8 kHz, the last one significantly higher than the other two. |
id |
ABORL-F-1_019baabb5624e502c838e0525ce5d659 |
---|---|
oai_identifier_str |
oai:scielo:S1808-86942015000600642 |
network_acronym_str |
ABORL-F-1 |
network_name_str |
Brazilian Journal of Otorhinolaryngology |
repository_id_str |
|
spelling |
Positioning of earphones and variations in auditory thresholds,Pure-tone audiometryAuditory thresholdOccupational healthABSTRACT INTRODUCTION: One of the problems observed in pure-tone audiometry tonal has been the variation in test results of a same individual, particularly at frequencies of 4 kHz, 6 kHz and/or 8 kHz. Improper placement of headphones is one of the factors that can cause alterations in results. OBJECTIVE: To compare differences in auditory thresholds using earphones positioned by the examiner and by the worker. METHODS: Clinical and experimental study conducted in 2009, with 324 workers aged between 19 and 61 years, with a mean of 33.29 years and mean exposure time of 7.67 years. All subjects were familiar with audiometry procedures. Auditory thresholds were obtained at frequencies of 0.25-8 kHz, with earphones positioned by the examiners, and at frequencies of 4, 6 and 8 kHz, with earphones placed by workers in a comfortable position, following the examiner's instructions. The thresholds obtained in these two situations were compared. RESULTS: The three frequencies exhibited better responses with earphones placed by the workers themselves (p < 0.001). At a frequency of 8 kHz a greater difference was found (p < 0.001), with a mean of 13.89 dB and standard deviation of 6.07 dB. CONCLUSION: Earphone placement by the workers themselves under supervision of the examiner results in improved mean auditory thresholds at frequencies of 4, 6 and 8 kHz, the last one significantly higher than the other two.Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.2015-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942015000600642Brazilian Journal of Otorhinolaryngology v.81 n.6 2015reponame:Brazilian Journal of Otorhinolaryngologyinstname:Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)instacron:ABORL-CCF10.1016/j.bjorl.2015.08.016info:eu-repo/semantics/openAccessAlmeida,Bettina PoggiMenezes,Pedro de LemosAndrade,Kelly Cristina Lira deTeixeira,Cleide Fernandeseng2016-01-05T00:00:00Zoai:scielo:S1808-86942015000600642Revistahttp://www.bjorl.org.br/https://old.scielo.br/oai/scielo-oai.phprevista@aborlccf.org.br||revista@aborlccf.org.br1808-86861808-8686opendoar:2016-01-05T00:00Brazilian Journal of Otorhinolaryngology - Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)false |
dc.title.none.fl_str_mv |
Positioning of earphones and variations in auditory thresholds, |
title |
Positioning of earphones and variations in auditory thresholds, |
spellingShingle |
Positioning of earphones and variations in auditory thresholds, Almeida,Bettina Poggi Pure-tone audiometry Auditory threshold Occupational health |
title_short |
Positioning of earphones and variations in auditory thresholds, |
title_full |
Positioning of earphones and variations in auditory thresholds, |
title_fullStr |
Positioning of earphones and variations in auditory thresholds, |
title_full_unstemmed |
Positioning of earphones and variations in auditory thresholds, |
title_sort |
Positioning of earphones and variations in auditory thresholds, |
author |
Almeida,Bettina Poggi |
author_facet |
Almeida,Bettina Poggi Menezes,Pedro de Lemos Andrade,Kelly Cristina Lira de Teixeira,Cleide Fernandes |
author_role |
author |
author2 |
Menezes,Pedro de Lemos Andrade,Kelly Cristina Lira de Teixeira,Cleide Fernandes |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Almeida,Bettina Poggi Menezes,Pedro de Lemos Andrade,Kelly Cristina Lira de Teixeira,Cleide Fernandes |
dc.subject.por.fl_str_mv |
Pure-tone audiometry Auditory threshold Occupational health |
topic |
Pure-tone audiometry Auditory threshold Occupational health |
description |
ABSTRACT INTRODUCTION: One of the problems observed in pure-tone audiometry tonal has been the variation in test results of a same individual, particularly at frequencies of 4 kHz, 6 kHz and/or 8 kHz. Improper placement of headphones is one of the factors that can cause alterations in results. OBJECTIVE: To compare differences in auditory thresholds using earphones positioned by the examiner and by the worker. METHODS: Clinical and experimental study conducted in 2009, with 324 workers aged between 19 and 61 years, with a mean of 33.29 years and mean exposure time of 7.67 years. All subjects were familiar with audiometry procedures. Auditory thresholds were obtained at frequencies of 0.25-8 kHz, with earphones positioned by the examiners, and at frequencies of 4, 6 and 8 kHz, with earphones placed by workers in a comfortable position, following the examiner's instructions. The thresholds obtained in these two situations were compared. RESULTS: The three frequencies exhibited better responses with earphones placed by the workers themselves (p < 0.001). At a frequency of 8 kHz a greater difference was found (p < 0.001), with a mean of 13.89 dB and standard deviation of 6.07 dB. CONCLUSION: Earphone placement by the workers themselves under supervision of the examiner results in improved mean auditory thresholds at frequencies of 4, 6 and 8 kHz, the last one significantly higher than the other two. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942015000600642 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942015000600642 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1016/j.bjorl.2015.08.016 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. |
publisher.none.fl_str_mv |
Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. |
dc.source.none.fl_str_mv |
Brazilian Journal of Otorhinolaryngology v.81 n.6 2015 reponame:Brazilian Journal of Otorhinolaryngology instname:Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF) instacron:ABORL-CCF |
instname_str |
Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF) |
instacron_str |
ABORL-CCF |
institution |
ABORL-CCF |
reponame_str |
Brazilian Journal of Otorhinolaryngology |
collection |
Brazilian Journal of Otorhinolaryngology |
repository.name.fl_str_mv |
Brazilian Journal of Otorhinolaryngology - Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF) |
repository.mail.fl_str_mv |
revista@aborlccf.org.br||revista@aborlccf.org.br |
_version_ |
1754575991718543360 |