Anatomical relationship of pterygoid process pneumatization and vidian canal

Detalhes bibliográficos
Autor(a) principal: Lakshman,Nanditha
Data de Publicação: 2022
Outros Autores: Viveka,S., Assanar,Fahad Bapu Thondupadath
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Otorhinolaryngology
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942022000300303
Resumo: Abstract Introduction The vidian canal acts as landmark for the identification of the petrous carotid artery, especially during extended endoscopic endonasal approaches in cranial base surgeries. In order to localize the canal and to understand the relationship of pneumatization of pterygoid process to the type of vidian canal, this study was designed. Objectives The objective was to describe the anatomical relationship of pneumatization of the pterygoid process with types of vidian canal. The length of vidian canal, relationship to medial plate of pterygoid process and relationship to the petrous part of internal carotid artery were evaluated. Methods Head computer tomography scans of 52 individuals for suspected paranasal pathology were studied. The degree of sphenoid sinus pneumatization, pterygoid process pneumatization and types of vidian canal (type 1, 2 and 3) were noted. The length of vidian canal, distance from the plane of medial pterygoid plate and relation of vidian canal to the junction of petrous and Gasserian (ascending) part of internal carotid artery was noted. Results 46 (92%) sphenoid sinuses were of the sellar variety. Out of 104 sides that were studied, 57 sides demonstrated a pneumatised pterygoid process and 47 were not pneumatised. In 49 sides (47.1%) the vidian canal was on the same plane as that of the medial pterygoid plate in the coronal section. The vidian canal partially protruded into the sphenoid sinus (type 2) was the most common type (50.9%), found both on right and left sides. There is a statistically significant association between the pterygoid process pneumatization and occurrence of type 2 and type 3 vidian canal configuration. The average length of the vidian canal was 16.16 ± 1.8 mm. In 96 sides, the anterior end of vidian canal was inferolateral to petrous part of internal carotid artery in the coronal plane. Conclusion Pneumatization of the pterygoid process indicates either type 2 or type 3 vidian canal configuration.
id ABORL-F-1_09c6572b26e4bc7c7c3b042c9b04a237
oai_identifier_str oai:scielo:S1808-86942022000300303
network_acronym_str ABORL-F-1
network_name_str Brazilian Journal of Otorhinolaryngology
repository_id_str
spelling Anatomical relationship of pterygoid process pneumatization and vidian canalVidian canalSphenoid boneCT scanningPneumatizationAbstract Introduction The vidian canal acts as landmark for the identification of the petrous carotid artery, especially during extended endoscopic endonasal approaches in cranial base surgeries. In order to localize the canal and to understand the relationship of pneumatization of pterygoid process to the type of vidian canal, this study was designed. Objectives The objective was to describe the anatomical relationship of pneumatization of the pterygoid process with types of vidian canal. The length of vidian canal, relationship to medial plate of pterygoid process and relationship to the petrous part of internal carotid artery were evaluated. Methods Head computer tomography scans of 52 individuals for suspected paranasal pathology were studied. The degree of sphenoid sinus pneumatization, pterygoid process pneumatization and types of vidian canal (type 1, 2 and 3) were noted. The length of vidian canal, distance from the plane of medial pterygoid plate and relation of vidian canal to the junction of petrous and Gasserian (ascending) part of internal carotid artery was noted. Results 46 (92%) sphenoid sinuses were of the sellar variety. Out of 104 sides that were studied, 57 sides demonstrated a pneumatised pterygoid process and 47 were not pneumatised. In 49 sides (47.1%) the vidian canal was on the same plane as that of the medial pterygoid plate in the coronal section. The vidian canal partially protruded into the sphenoid sinus (type 2) was the most common type (50.9%), found both on right and left sides. There is a statistically significant association between the pterygoid process pneumatization and occurrence of type 2 and type 3 vidian canal configuration. The average length of the vidian canal was 16.16 ± 1.8 mm. In 96 sides, the anterior end of vidian canal was inferolateral to petrous part of internal carotid artery in the coronal plane. Conclusion Pneumatization of the pterygoid process indicates either type 2 or type 3 vidian canal configuration.Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.2022-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942022000300303Brazilian Journal of Otorhinolaryngology v.88 n.3 2022reponame:Brazilian Journal of Otorhinolaryngologyinstname:Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)instacron:ABORL-CCF10.1016/j.bjorl.2020.06.005info:eu-repo/semantics/openAccessLakshman,NandithaViveka,S.Assanar,Fahad Bapu Thondupadatheng2022-06-23T00:00:00Zoai:scielo:S1808-86942022000300303Revistahttp://www.bjorl.org.br/https://old.scielo.br/oai/scielo-oai.phprevista@aborlccf.org.br||revista@aborlccf.org.br1808-86861808-8686opendoar:2022-06-23T00:00Brazilian Journal of Otorhinolaryngology - Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)false
dc.title.none.fl_str_mv Anatomical relationship of pterygoid process pneumatization and vidian canal
title Anatomical relationship of pterygoid process pneumatization and vidian canal
spellingShingle Anatomical relationship of pterygoid process pneumatization and vidian canal
Lakshman,Nanditha
Vidian canal
Sphenoid bone
CT scanning
Pneumatization
title_short Anatomical relationship of pterygoid process pneumatization and vidian canal
title_full Anatomical relationship of pterygoid process pneumatization and vidian canal
title_fullStr Anatomical relationship of pterygoid process pneumatization and vidian canal
title_full_unstemmed Anatomical relationship of pterygoid process pneumatization and vidian canal
title_sort Anatomical relationship of pterygoid process pneumatization and vidian canal
author Lakshman,Nanditha
author_facet Lakshman,Nanditha
Viveka,S.
Assanar,Fahad Bapu Thondupadath
author_role author
author2 Viveka,S.
Assanar,Fahad Bapu Thondupadath
author2_role author
author
dc.contributor.author.fl_str_mv Lakshman,Nanditha
Viveka,S.
Assanar,Fahad Bapu Thondupadath
dc.subject.por.fl_str_mv Vidian canal
Sphenoid bone
CT scanning
Pneumatization
topic Vidian canal
Sphenoid bone
CT scanning
Pneumatization
description Abstract Introduction The vidian canal acts as landmark for the identification of the petrous carotid artery, especially during extended endoscopic endonasal approaches in cranial base surgeries. In order to localize the canal and to understand the relationship of pneumatization of pterygoid process to the type of vidian canal, this study was designed. Objectives The objective was to describe the anatomical relationship of pneumatization of the pterygoid process with types of vidian canal. The length of vidian canal, relationship to medial plate of pterygoid process and relationship to the petrous part of internal carotid artery were evaluated. Methods Head computer tomography scans of 52 individuals for suspected paranasal pathology were studied. The degree of sphenoid sinus pneumatization, pterygoid process pneumatization and types of vidian canal (type 1, 2 and 3) were noted. The length of vidian canal, distance from the plane of medial pterygoid plate and relation of vidian canal to the junction of petrous and Gasserian (ascending) part of internal carotid artery was noted. Results 46 (92%) sphenoid sinuses were of the sellar variety. Out of 104 sides that were studied, 57 sides demonstrated a pneumatised pterygoid process and 47 were not pneumatised. In 49 sides (47.1%) the vidian canal was on the same plane as that of the medial pterygoid plate in the coronal section. The vidian canal partially protruded into the sphenoid sinus (type 2) was the most common type (50.9%), found both on right and left sides. There is a statistically significant association between the pterygoid process pneumatization and occurrence of type 2 and type 3 vidian canal configuration. The average length of the vidian canal was 16.16 ± 1.8 mm. In 96 sides, the anterior end of vidian canal was inferolateral to petrous part of internal carotid artery in the coronal plane. Conclusion Pneumatization of the pterygoid process indicates either type 2 or type 3 vidian canal configuration.
publishDate 2022
dc.date.none.fl_str_mv 2022-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942022000300303
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942022000300303
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.bjorl.2020.06.005
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.
publisher.none.fl_str_mv Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.
dc.source.none.fl_str_mv Brazilian Journal of Otorhinolaryngology v.88 n.3 2022
reponame:Brazilian Journal of Otorhinolaryngology
instname:Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)
instacron:ABORL-CCF
instname_str Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)
instacron_str ABORL-CCF
institution ABORL-CCF
reponame_str Brazilian Journal of Otorhinolaryngology
collection Brazilian Journal of Otorhinolaryngology
repository.name.fl_str_mv Brazilian Journal of Otorhinolaryngology - Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)
repository.mail.fl_str_mv revista@aborlccf.org.br||revista@aborlccf.org.br
_version_ 1754575994945011712