Tinnitus and normal hearing: a study on the transient otoacoustic emissions suppression
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Journal of Otorhinolaryngology |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942009000300017 |
Resumo: | The workings of the auditory pathway of patients with tinnitus and normal hearing can be associated with an auditory efferent pathway dysfunction at the level of the superior olivary complex. Otoacoustic emission suppression with contralateral noise can represent an alternative to its evaluation. AIM:to investigate Transient Otoacoustic Emission suppression in normal hearing adults with and without tinnitus and to compare the two groups. Study design: cross-sectional contemporary cohort. MATERIALS AND METHODS: we assessed 40 female individuals between 18 and 59 years of age, 20 without tinnitus and 20 with it. We studied the TOAE suppression with a contralateral white noise at 50 dBSPL. RESULTS: TOAE amplitude was lower in the group with tinnitus. There was no difference between the groups with and without tinnitus in terms of TOAE suppression, except in the frequency of 1000 Hz in the left ear in the tinnitus group. CONCLUSION: the afferent system assessment may contribute to the topographic diagnosis of tinnitus; however, we still need further studies to establish the proper methodology and normative values to carry out these tests. |
id |
ABORL-F-1_a3c8c5b9cabaaca5f553f2d8a4058481 |
---|---|
oai_identifier_str |
oai:scielo:S1808-86942009000300017 |
network_acronym_str |
ABORL-F-1 |
network_name_str |
Brazilian Journal of Otorhinolaryngology |
repository_id_str |
|
spelling |
Tinnitus and normal hearing: a study on the transient otoacoustic emissions suppressionefferent pathwaysacoustic stimulationtinnitusThe workings of the auditory pathway of patients with tinnitus and normal hearing can be associated with an auditory efferent pathway dysfunction at the level of the superior olivary complex. Otoacoustic emission suppression with contralateral noise can represent an alternative to its evaluation. AIM:to investigate Transient Otoacoustic Emission suppression in normal hearing adults with and without tinnitus and to compare the two groups. Study design: cross-sectional contemporary cohort. MATERIALS AND METHODS: we assessed 40 female individuals between 18 and 59 years of age, 20 without tinnitus and 20 with it. We studied the TOAE suppression with a contralateral white noise at 50 dBSPL. RESULTS: TOAE amplitude was lower in the group with tinnitus. There was no difference between the groups with and without tinnitus in terms of TOAE suppression, except in the frequency of 1000 Hz in the left ear in the tinnitus group. CONCLUSION: the afferent system assessment may contribute to the topographic diagnosis of tinnitus; however, we still need further studies to establish the proper methodology and normative values to carry out these tests.Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.2009-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942009000300017Brazilian Journal of Otorhinolaryngology v.75 n.3 2009reponame:Brazilian Journal of Otorhinolaryngologyinstname:Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)instacron:ABORL-CCF10.1590/S1808-86942009000300017info:eu-repo/semantics/openAccessFernandes,Luciene da CruzSantos,Teresa Maria Momensohn doseng2009-07-27T00:00:00Zoai:scielo:S1808-86942009000300017Revistahttp://www.bjorl.org.br/https://old.scielo.br/oai/scielo-oai.phprevista@aborlccf.org.br||revista@aborlccf.org.br1808-86861808-8686opendoar:2009-07-27T00:00Brazilian Journal of Otorhinolaryngology - Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)false |
dc.title.none.fl_str_mv |
Tinnitus and normal hearing: a study on the transient otoacoustic emissions suppression |
title |
Tinnitus and normal hearing: a study on the transient otoacoustic emissions suppression |
spellingShingle |
Tinnitus and normal hearing: a study on the transient otoacoustic emissions suppression Fernandes,Luciene da Cruz efferent pathways acoustic stimulation tinnitus |
title_short |
Tinnitus and normal hearing: a study on the transient otoacoustic emissions suppression |
title_full |
Tinnitus and normal hearing: a study on the transient otoacoustic emissions suppression |
title_fullStr |
Tinnitus and normal hearing: a study on the transient otoacoustic emissions suppression |
title_full_unstemmed |
Tinnitus and normal hearing: a study on the transient otoacoustic emissions suppression |
title_sort |
Tinnitus and normal hearing: a study on the transient otoacoustic emissions suppression |
author |
Fernandes,Luciene da Cruz |
author_facet |
Fernandes,Luciene da Cruz Santos,Teresa Maria Momensohn dos |
author_role |
author |
author2 |
Santos,Teresa Maria Momensohn dos |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Fernandes,Luciene da Cruz Santos,Teresa Maria Momensohn dos |
dc.subject.por.fl_str_mv |
efferent pathways acoustic stimulation tinnitus |
topic |
efferent pathways acoustic stimulation tinnitus |
description |
The workings of the auditory pathway of patients with tinnitus and normal hearing can be associated with an auditory efferent pathway dysfunction at the level of the superior olivary complex. Otoacoustic emission suppression with contralateral noise can represent an alternative to its evaluation. AIM:to investigate Transient Otoacoustic Emission suppression in normal hearing adults with and without tinnitus and to compare the two groups. Study design: cross-sectional contemporary cohort. MATERIALS AND METHODS: we assessed 40 female individuals between 18 and 59 years of age, 20 without tinnitus and 20 with it. We studied the TOAE suppression with a contralateral white noise at 50 dBSPL. RESULTS: TOAE amplitude was lower in the group with tinnitus. There was no difference between the groups with and without tinnitus in terms of TOAE suppression, except in the frequency of 1000 Hz in the left ear in the tinnitus group. CONCLUSION: the afferent system assessment may contribute to the topographic diagnosis of tinnitus; however, we still need further studies to establish the proper methodology and normative values to carry out these tests. |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942009000300017 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942009000300017 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1808-86942009000300017 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. |
publisher.none.fl_str_mv |
Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. |
dc.source.none.fl_str_mv |
Brazilian Journal of Otorhinolaryngology v.75 n.3 2009 reponame:Brazilian Journal of Otorhinolaryngology instname:Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF) instacron:ABORL-CCF |
instname_str |
Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF) |
instacron_str |
ABORL-CCF |
institution |
ABORL-CCF |
reponame_str |
Brazilian Journal of Otorhinolaryngology |
collection |
Brazilian Journal of Otorhinolaryngology |
repository.name.fl_str_mv |
Brazilian Journal of Otorhinolaryngology - Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF) |
repository.mail.fl_str_mv |
revista@aborlccf.org.br||revista@aborlccf.org.br |
_version_ |
1754575988454326272 |