High frequency hearing thresholds and product distortion otoacoustic emissions in cystic fibrosis patients,

Detalhes bibliográficos
Autor(a) principal: Geyer,Lucia Bencke
Data de Publicação: 2015
Outros Autores: Barreto,Sergio Saldanha Menna, Weigert,Liese Loureiro, Teixeira,Adriane Ribeiro
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Otorhinolaryngology
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942015000600589
Resumo: ABSTRACT INTRODUCTION: The treatment of patients with cystic fibrosis involves the use of ototoxic drugs, mainly aminoglycoside antibiotics. Due to the use of these drugs, fibrocystic patients are at risk of developing hearing loss. OBJECTIVE: To evaluate the hearing of patients with cystic fibrosis by High Frequency Audiometry and Distortion Product Otoacoustic Emissions. METHODS: Cross-sectional study. The study group consisted of 39 patients (7-20 years of age) with cystic fibrosis and a control group of 36 individuals in the same age group without otologic complaints, with normal audiometric thresholds and type A tympanometric curves. High Frequency Audiometry and Distortion Product Otoacoustic Emissions tests were conducted. RESULTS: The study group had significantly higher thresholds at 250, 1000, 8000, 9000, 10,000, 12,500, and 16,000 Hz (p = 0.004) as well as higher prevalence of otoacoustic emission alterations at 1000 and 6000 Hz (p = 0.001), with significantly lower amplitudes at 1000, 1400, and 6000 Hz. There was a significant association between alterations in hearing thresholds in High Frequency Audiometry with the number of courses of aminoglycosides administered (p = 0.005). Eighty-three percent of patients who completed more than ten courses of aminoglycosides had hearing loss in High Frequency Audiometry. CONCLUSION: A significant number of patients with cystic fibrosis who received repeated courses of aminoglycosides showed alterations in High Frequency Audiometry and Distortion Product Otoacoustic Emissions. The implementation of ten or more aminoglycoside cycles was associated with alterations in High Frequency Audiometry.
id ABORL-F-1_cbeea4bb3847114b7de0563ffb52cc8c
oai_identifier_str oai:scielo:S1808-86942015000600589
network_acronym_str ABORL-F-1
network_name_str Brazilian Journal of Otorhinolaryngology
repository_id_str
spelling High frequency hearing thresholds and product distortion otoacoustic emissions in cystic fibrosis patients,Cystic fibrosisAminoglycosidesAudiometryABSTRACT INTRODUCTION: The treatment of patients with cystic fibrosis involves the use of ototoxic drugs, mainly aminoglycoside antibiotics. Due to the use of these drugs, fibrocystic patients are at risk of developing hearing loss. OBJECTIVE: To evaluate the hearing of patients with cystic fibrosis by High Frequency Audiometry and Distortion Product Otoacoustic Emissions. METHODS: Cross-sectional study. The study group consisted of 39 patients (7-20 years of age) with cystic fibrosis and a control group of 36 individuals in the same age group without otologic complaints, with normal audiometric thresholds and type A tympanometric curves. High Frequency Audiometry and Distortion Product Otoacoustic Emissions tests were conducted. RESULTS: The study group had significantly higher thresholds at 250, 1000, 8000, 9000, 10,000, 12,500, and 16,000 Hz (p = 0.004) as well as higher prevalence of otoacoustic emission alterations at 1000 and 6000 Hz (p = 0.001), with significantly lower amplitudes at 1000, 1400, and 6000 Hz. There was a significant association between alterations in hearing thresholds in High Frequency Audiometry with the number of courses of aminoglycosides administered (p = 0.005). Eighty-three percent of patients who completed more than ten courses of aminoglycosides had hearing loss in High Frequency Audiometry. CONCLUSION: A significant number of patients with cystic fibrosis who received repeated courses of aminoglycosides showed alterations in High Frequency Audiometry and Distortion Product Otoacoustic Emissions. The implementation of ten or more aminoglycoside cycles was associated with alterations in High Frequency Audiometry.Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.2015-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942015000600589Brazilian Journal of Otorhinolaryngology v.81 n.6 2015reponame:Brazilian Journal of Otorhinolaryngologyinstname:Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)instacron:ABORL-CCF10.1016/j.bjorl.2015.08.011info:eu-repo/semantics/openAccessGeyer,Lucia BenckeBarreto,Sergio Saldanha MennaWeigert,Liese LoureiroTeixeira,Adriane Ribeiroeng2016-01-05T00:00:00Zoai:scielo:S1808-86942015000600589Revistahttp://www.bjorl.org.br/https://old.scielo.br/oai/scielo-oai.phprevista@aborlccf.org.br||revista@aborlccf.org.br1808-86861808-8686opendoar:2016-01-05T00:00Brazilian Journal of Otorhinolaryngology - Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)false
dc.title.none.fl_str_mv High frequency hearing thresholds and product distortion otoacoustic emissions in cystic fibrosis patients,
title High frequency hearing thresholds and product distortion otoacoustic emissions in cystic fibrosis patients,
spellingShingle High frequency hearing thresholds and product distortion otoacoustic emissions in cystic fibrosis patients,
Geyer,Lucia Bencke
Cystic fibrosis
Aminoglycosides
Audiometry
title_short High frequency hearing thresholds and product distortion otoacoustic emissions in cystic fibrosis patients,
title_full High frequency hearing thresholds and product distortion otoacoustic emissions in cystic fibrosis patients,
title_fullStr High frequency hearing thresholds and product distortion otoacoustic emissions in cystic fibrosis patients,
title_full_unstemmed High frequency hearing thresholds and product distortion otoacoustic emissions in cystic fibrosis patients,
title_sort High frequency hearing thresholds and product distortion otoacoustic emissions in cystic fibrosis patients,
author Geyer,Lucia Bencke
author_facet Geyer,Lucia Bencke
Barreto,Sergio Saldanha Menna
Weigert,Liese Loureiro
Teixeira,Adriane Ribeiro
author_role author
author2 Barreto,Sergio Saldanha Menna
Weigert,Liese Loureiro
Teixeira,Adriane Ribeiro
author2_role author
author
author
dc.contributor.author.fl_str_mv Geyer,Lucia Bencke
Barreto,Sergio Saldanha Menna
Weigert,Liese Loureiro
Teixeira,Adriane Ribeiro
dc.subject.por.fl_str_mv Cystic fibrosis
Aminoglycosides
Audiometry
topic Cystic fibrosis
Aminoglycosides
Audiometry
description ABSTRACT INTRODUCTION: The treatment of patients with cystic fibrosis involves the use of ototoxic drugs, mainly aminoglycoside antibiotics. Due to the use of these drugs, fibrocystic patients are at risk of developing hearing loss. OBJECTIVE: To evaluate the hearing of patients with cystic fibrosis by High Frequency Audiometry and Distortion Product Otoacoustic Emissions. METHODS: Cross-sectional study. The study group consisted of 39 patients (7-20 years of age) with cystic fibrosis and a control group of 36 individuals in the same age group without otologic complaints, with normal audiometric thresholds and type A tympanometric curves. High Frequency Audiometry and Distortion Product Otoacoustic Emissions tests were conducted. RESULTS: The study group had significantly higher thresholds at 250, 1000, 8000, 9000, 10,000, 12,500, and 16,000 Hz (p = 0.004) as well as higher prevalence of otoacoustic emission alterations at 1000 and 6000 Hz (p = 0.001), with significantly lower amplitudes at 1000, 1400, and 6000 Hz. There was a significant association between alterations in hearing thresholds in High Frequency Audiometry with the number of courses of aminoglycosides administered (p = 0.005). Eighty-three percent of patients who completed more than ten courses of aminoglycosides had hearing loss in High Frequency Audiometry. CONCLUSION: A significant number of patients with cystic fibrosis who received repeated courses of aminoglycosides showed alterations in High Frequency Audiometry and Distortion Product Otoacoustic Emissions. The implementation of ten or more aminoglycoside cycles was associated with alterations in High Frequency Audiometry.
publishDate 2015
dc.date.none.fl_str_mv 2015-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942015000600589
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942015000600589
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.bjorl.2015.08.011
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.
publisher.none.fl_str_mv Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.
dc.source.none.fl_str_mv Brazilian Journal of Otorhinolaryngology v.81 n.6 2015
reponame:Brazilian Journal of Otorhinolaryngology
instname:Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)
instacron:ABORL-CCF
instname_str Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)
instacron_str ABORL-CCF
institution ABORL-CCF
reponame_str Brazilian Journal of Otorhinolaryngology
collection Brazilian Journal of Otorhinolaryngology
repository.name.fl_str_mv Brazilian Journal of Otorhinolaryngology - Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)
repository.mail.fl_str_mv revista@aborlccf.org.br||revista@aborlccf.org.br
_version_ 1754575991703863296