Subjective visual vertical with the bucket method in Brazilian healthy individuals

Detalhes bibliográficos
Autor(a) principal: Ferreira,Maristela Mian
Data de Publicação: 2016
Outros Autores: Cunha,Fabiana, Ganança,Cristina Freitas, Ganança,Maurício Malavasi, Caovilla,Heloisa Helena
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Otorhinolaryngology
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942016000400442
Resumo: ABSTRACT INTRODUCTION: The capacity of a healthy individual to estimate the true vertical in relation to the Earth when a fluorescent line is aligned in a completely dark room is called the subjective visual vertical. OBJECTIVE: To evaluate subjective visual vertical using the bucket method in healthy Brazilian individuals. METHODS: Binocular subjective visual vertical was measured in 100 healthy volunteers, 50 females and 50 males. The volunteers indicated the estimated position in which a fluorescent line inside a bucket reached the vertical position. A total of ten repetitions were performed, five clockwise and five counterclockwise. Data were tabulated and analyzed statistically. RESULTS: It was observed that the highest concentration of absolute values of vertical deviation was present up to 3°, regardless of gender, and the vertical deviation did not increase with age. The analysis of the mean of the absolute values of deviations from the vertical of 90% of the sample showed a maximum value of 2.6°, and at the analysis of 95%, the maximum value was 3.4° deviation from the vertical. CONCLUSION: The bucket method is easy to perform and interpret when assessing the deviation of the subjective visual vertical in relation to the true vertical in healthy Brazilian individuals.
id ABORL-F-1_ccc092571984d94a14ce0b2f121b93db
oai_identifier_str oai:scielo:S1808-86942016000400442
network_acronym_str ABORL-F-1
network_name_str Brazilian Journal of Otorhinolaryngology
repository_id_str
spelling Subjective visual vertical with the bucket method in Brazilian healthy individualsEarPostural balanceOtolithic membraneABSTRACT INTRODUCTION: The capacity of a healthy individual to estimate the true vertical in relation to the Earth when a fluorescent line is aligned in a completely dark room is called the subjective visual vertical. OBJECTIVE: To evaluate subjective visual vertical using the bucket method in healthy Brazilian individuals. METHODS: Binocular subjective visual vertical was measured in 100 healthy volunteers, 50 females and 50 males. The volunteers indicated the estimated position in which a fluorescent line inside a bucket reached the vertical position. A total of ten repetitions were performed, five clockwise and five counterclockwise. Data were tabulated and analyzed statistically. RESULTS: It was observed that the highest concentration of absolute values of vertical deviation was present up to 3°, regardless of gender, and the vertical deviation did not increase with age. The analysis of the mean of the absolute values of deviations from the vertical of 90% of the sample showed a maximum value of 2.6°, and at the analysis of 95%, the maximum value was 3.4° deviation from the vertical. CONCLUSION: The bucket method is easy to perform and interpret when assessing the deviation of the subjective visual vertical in relation to the true vertical in healthy Brazilian individuals.Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.2016-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942016000400442Brazilian Journal of Otorhinolaryngology v.82 n.4 2016reponame:Brazilian Journal of Otorhinolaryngologyinstname:Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)instacron:ABORL-CCF10.1016/j.bjorl.2015.08.027info:eu-repo/semantics/openAccessFerreira,Maristela MianCunha,FabianaGanança,Cristina FreitasGanança,Maurício MalavasiCaovilla,Heloisa Helenaeng2016-09-09T00:00:00Zoai:scielo:S1808-86942016000400442Revistahttp://www.bjorl.org.br/https://old.scielo.br/oai/scielo-oai.phprevista@aborlccf.org.br||revista@aborlccf.org.br1808-86861808-8686opendoar:2016-09-09T00:00Brazilian Journal of Otorhinolaryngology - Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)false
dc.title.none.fl_str_mv Subjective visual vertical with the bucket method in Brazilian healthy individuals
title Subjective visual vertical with the bucket method in Brazilian healthy individuals
spellingShingle Subjective visual vertical with the bucket method in Brazilian healthy individuals
Ferreira,Maristela Mian
Ear
Postural balance
Otolithic membrane
title_short Subjective visual vertical with the bucket method in Brazilian healthy individuals
title_full Subjective visual vertical with the bucket method in Brazilian healthy individuals
title_fullStr Subjective visual vertical with the bucket method in Brazilian healthy individuals
title_full_unstemmed Subjective visual vertical with the bucket method in Brazilian healthy individuals
title_sort Subjective visual vertical with the bucket method in Brazilian healthy individuals
author Ferreira,Maristela Mian
author_facet Ferreira,Maristela Mian
Cunha,Fabiana
Ganança,Cristina Freitas
Ganança,Maurício Malavasi
Caovilla,Heloisa Helena
author_role author
author2 Cunha,Fabiana
Ganança,Cristina Freitas
Ganança,Maurício Malavasi
Caovilla,Heloisa Helena
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Ferreira,Maristela Mian
Cunha,Fabiana
Ganança,Cristina Freitas
Ganança,Maurício Malavasi
Caovilla,Heloisa Helena
dc.subject.por.fl_str_mv Ear
Postural balance
Otolithic membrane
topic Ear
Postural balance
Otolithic membrane
description ABSTRACT INTRODUCTION: The capacity of a healthy individual to estimate the true vertical in relation to the Earth when a fluorescent line is aligned in a completely dark room is called the subjective visual vertical. OBJECTIVE: To evaluate subjective visual vertical using the bucket method in healthy Brazilian individuals. METHODS: Binocular subjective visual vertical was measured in 100 healthy volunteers, 50 females and 50 males. The volunteers indicated the estimated position in which a fluorescent line inside a bucket reached the vertical position. A total of ten repetitions were performed, five clockwise and five counterclockwise. Data were tabulated and analyzed statistically. RESULTS: It was observed that the highest concentration of absolute values of vertical deviation was present up to 3°, regardless of gender, and the vertical deviation did not increase with age. The analysis of the mean of the absolute values of deviations from the vertical of 90% of the sample showed a maximum value of 2.6°, and at the analysis of 95%, the maximum value was 3.4° deviation from the vertical. CONCLUSION: The bucket method is easy to perform and interpret when assessing the deviation of the subjective visual vertical in relation to the true vertical in healthy Brazilian individuals.
publishDate 2016
dc.date.none.fl_str_mv 2016-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942016000400442
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942016000400442
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.bjorl.2015.08.027
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.
publisher.none.fl_str_mv Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.
dc.source.none.fl_str_mv Brazilian Journal of Otorhinolaryngology v.82 n.4 2016
reponame:Brazilian Journal of Otorhinolaryngology
instname:Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)
instacron:ABORL-CCF
instname_str Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)
instacron_str ABORL-CCF
institution ABORL-CCF
reponame_str Brazilian Journal of Otorhinolaryngology
collection Brazilian Journal of Otorhinolaryngology
repository.name.fl_str_mv Brazilian Journal of Otorhinolaryngology - Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)
repository.mail.fl_str_mv revista@aborlccf.org.br||revista@aborlccf.org.br
_version_ 1754575992107565056