Does size of the cochlear nerve affect postoperative auditory performance in pediatric cochlear implant patients with normal cochlear nerves?

Detalhes bibliográficos
Autor(a) principal: Gozen,Emine Deniz
Data de Publicação: 2022
Outros Autores: Yener,H. Murat, Kara,Halide, Atas,Ahmet, Kizilkilic,Osman, Cansiz,Harun
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Otorhinolaryngology
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942022000300390
Resumo: Abstract Introduction Cochlear implantation is an effective treatment method for severe to profound hearing loss. Many factors that may influence cochlear implantation success have been explained in previous studies. Apart from those, minor differences in size of normal cochlear nerves may affect postoperative performance. Objective To investigate whether the minor differences in cochlear nerve size in normal cochlear nerves affect postoperative cochlear implant performance. Methods 30 pediatric prelingually deaf patients who were treated with cochlear implantation were included in this study. From the reconstructed parasagittal magnetic resonance images, the diameter and cross-sectional area of the cochlear nerve on the ipsilateral and contralateral side were measured. Auditory evaluations were performed 1, 3, 6 and 12 months following the first fitting. All the analysis was performed by using EARS®, evaluation of auditory responses to speech tool. Correlation between cochlear nerve diameter, cross-sectional area and postoperative auditory perception was analyzed to determine whether variation in cochlear nerve size contributes to postoperative auditory performance. Results The mean diameter of the cochlear nerve on the ipsilateral side was 718.4 μm (504.5 − 904.3 μm) and mean cross sectional area was 0.015 cm2 (0.012 − 0.018 cm2). On the contralateral side the mean cochlear nerve diameter was 714.4 μm (502.6 − 951.4 μm) and mean cross sectional area was 0.014 cm2 (0.011 − 0.019 cm2). The correlation between the diameter and cross-sectional area of the ipsilateral and contralateral cochlear nerve revealed no significance. Mean score at first month monosyllable-trochee-polysyllable test, MTP1, was 0.17 (0.08 − 0.33), at 6th month with 6 words test, 6th month MTP6 was 0.72 (0.39 − 1.0), at 6th month with 12 words, 6th month MTP 12 was 0.46 (0.17 − 0.75) and at 12th month with 12 words, 12th month MTP12 was 0.73 (0.25 − 1.0). There was no correlation between the monosyllable-trochee-polysyllable test, values at any time with the diameter of the ipsilateral cochlear nerve. However, the first month MTP, 6th month MTP6 and 12th month MTP12 correlated with the cross-sectional area of the ipsilateral cochlear nerve. Conclusion Measuring the cross sectional area of the normal- appearing cochlear nerve may give important prognostic knowledge on cochlear implant outcomes. In patients with a larger cross sectional area the auditory performance was better and faster. Although normal appearing, slight differences on cross sectional area of the cochlear nerve may affect performance. Measuring the size of the cochlear nerve on parasagittal magnetic resonance images may provide beneficial information on the postoperative rehabilitation process.
id ABORL-F-1_ddeb4bc9fb3fb99a0e7a0e691dd819b6
oai_identifier_str oai:scielo:S1808-86942022000300390
network_acronym_str ABORL-F-1
network_name_str Brazilian Journal of Otorhinolaryngology
repository_id_str
spelling Does size of the cochlear nerve affect postoperative auditory performance in pediatric cochlear implant patients with normal cochlear nerves?Cochlear implantationPrelingual deafnessCochlear nerve morphologyAuditory perceptionAbstract Introduction Cochlear implantation is an effective treatment method for severe to profound hearing loss. Many factors that may influence cochlear implantation success have been explained in previous studies. Apart from those, minor differences in size of normal cochlear nerves may affect postoperative performance. Objective To investigate whether the minor differences in cochlear nerve size in normal cochlear nerves affect postoperative cochlear implant performance. Methods 30 pediatric prelingually deaf patients who were treated with cochlear implantation were included in this study. From the reconstructed parasagittal magnetic resonance images, the diameter and cross-sectional area of the cochlear nerve on the ipsilateral and contralateral side were measured. Auditory evaluations were performed 1, 3, 6 and 12 months following the first fitting. All the analysis was performed by using EARS®, evaluation of auditory responses to speech tool. Correlation between cochlear nerve diameter, cross-sectional area and postoperative auditory perception was analyzed to determine whether variation in cochlear nerve size contributes to postoperative auditory performance. Results The mean diameter of the cochlear nerve on the ipsilateral side was 718.4 μm (504.5 − 904.3 μm) and mean cross sectional area was 0.015 cm2 (0.012 − 0.018 cm2). On the contralateral side the mean cochlear nerve diameter was 714.4 μm (502.6 − 951.4 μm) and mean cross sectional area was 0.014 cm2 (0.011 − 0.019 cm2). The correlation between the diameter and cross-sectional area of the ipsilateral and contralateral cochlear nerve revealed no significance. Mean score at first month monosyllable-trochee-polysyllable test, MTP1, was 0.17 (0.08 − 0.33), at 6th month with 6 words test, 6th month MTP6 was 0.72 (0.39 − 1.0), at 6th month with 12 words, 6th month MTP 12 was 0.46 (0.17 − 0.75) and at 12th month with 12 words, 12th month MTP12 was 0.73 (0.25 − 1.0). There was no correlation between the monosyllable-trochee-polysyllable test, values at any time with the diameter of the ipsilateral cochlear nerve. However, the first month MTP, 6th month MTP6 and 12th month MTP12 correlated with the cross-sectional area of the ipsilateral cochlear nerve. Conclusion Measuring the cross sectional area of the normal- appearing cochlear nerve may give important prognostic knowledge on cochlear implant outcomes. In patients with a larger cross sectional area the auditory performance was better and faster. Although normal appearing, slight differences on cross sectional area of the cochlear nerve may affect performance. Measuring the size of the cochlear nerve on parasagittal magnetic resonance images may provide beneficial information on the postoperative rehabilitation process.Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.2022-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942022000300390Brazilian Journal of Otorhinolaryngology v.88 n.3 2022reponame:Brazilian Journal of Otorhinolaryngologyinstname:Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)instacron:ABORL-CCF10.1016/j.bjorl.2020.06.019info:eu-repo/semantics/openAccessGozen,Emine DenizYener,H. MuratKara,HalideAtas,AhmetKizilkilic,OsmanCansiz,Haruneng2022-06-23T00:00:00Zoai:scielo:S1808-86942022000300390Revistahttp://www.bjorl.org.br/https://old.scielo.br/oai/scielo-oai.phprevista@aborlccf.org.br||revista@aborlccf.org.br1808-86861808-8686opendoar:2022-06-23T00:00Brazilian Journal of Otorhinolaryngology - Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)false
dc.title.none.fl_str_mv Does size of the cochlear nerve affect postoperative auditory performance in pediatric cochlear implant patients with normal cochlear nerves?
title Does size of the cochlear nerve affect postoperative auditory performance in pediatric cochlear implant patients with normal cochlear nerves?
spellingShingle Does size of the cochlear nerve affect postoperative auditory performance in pediatric cochlear implant patients with normal cochlear nerves?
Gozen,Emine Deniz
Cochlear implantation
Prelingual deafness
Cochlear nerve morphology
Auditory perception
title_short Does size of the cochlear nerve affect postoperative auditory performance in pediatric cochlear implant patients with normal cochlear nerves?
title_full Does size of the cochlear nerve affect postoperative auditory performance in pediatric cochlear implant patients with normal cochlear nerves?
title_fullStr Does size of the cochlear nerve affect postoperative auditory performance in pediatric cochlear implant patients with normal cochlear nerves?
title_full_unstemmed Does size of the cochlear nerve affect postoperative auditory performance in pediatric cochlear implant patients with normal cochlear nerves?
title_sort Does size of the cochlear nerve affect postoperative auditory performance in pediatric cochlear implant patients with normal cochlear nerves?
author Gozen,Emine Deniz
author_facet Gozen,Emine Deniz
Yener,H. Murat
Kara,Halide
Atas,Ahmet
Kizilkilic,Osman
Cansiz,Harun
author_role author
author2 Yener,H. Murat
Kara,Halide
Atas,Ahmet
Kizilkilic,Osman
Cansiz,Harun
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Gozen,Emine Deniz
Yener,H. Murat
Kara,Halide
Atas,Ahmet
Kizilkilic,Osman
Cansiz,Harun
dc.subject.por.fl_str_mv Cochlear implantation
Prelingual deafness
Cochlear nerve morphology
Auditory perception
topic Cochlear implantation
Prelingual deafness
Cochlear nerve morphology
Auditory perception
description Abstract Introduction Cochlear implantation is an effective treatment method for severe to profound hearing loss. Many factors that may influence cochlear implantation success have been explained in previous studies. Apart from those, minor differences in size of normal cochlear nerves may affect postoperative performance. Objective To investigate whether the minor differences in cochlear nerve size in normal cochlear nerves affect postoperative cochlear implant performance. Methods 30 pediatric prelingually deaf patients who were treated with cochlear implantation were included in this study. From the reconstructed parasagittal magnetic resonance images, the diameter and cross-sectional area of the cochlear nerve on the ipsilateral and contralateral side were measured. Auditory evaluations were performed 1, 3, 6 and 12 months following the first fitting. All the analysis was performed by using EARS®, evaluation of auditory responses to speech tool. Correlation between cochlear nerve diameter, cross-sectional area and postoperative auditory perception was analyzed to determine whether variation in cochlear nerve size contributes to postoperative auditory performance. Results The mean diameter of the cochlear nerve on the ipsilateral side was 718.4 μm (504.5 − 904.3 μm) and mean cross sectional area was 0.015 cm2 (0.012 − 0.018 cm2). On the contralateral side the mean cochlear nerve diameter was 714.4 μm (502.6 − 951.4 μm) and mean cross sectional area was 0.014 cm2 (0.011 − 0.019 cm2). The correlation between the diameter and cross-sectional area of the ipsilateral and contralateral cochlear nerve revealed no significance. Mean score at first month monosyllable-trochee-polysyllable test, MTP1, was 0.17 (0.08 − 0.33), at 6th month with 6 words test, 6th month MTP6 was 0.72 (0.39 − 1.0), at 6th month with 12 words, 6th month MTP 12 was 0.46 (0.17 − 0.75) and at 12th month with 12 words, 12th month MTP12 was 0.73 (0.25 − 1.0). There was no correlation between the monosyllable-trochee-polysyllable test, values at any time with the diameter of the ipsilateral cochlear nerve. However, the first month MTP, 6th month MTP6 and 12th month MTP12 correlated with the cross-sectional area of the ipsilateral cochlear nerve. Conclusion Measuring the cross sectional area of the normal- appearing cochlear nerve may give important prognostic knowledge on cochlear implant outcomes. In patients with a larger cross sectional area the auditory performance was better and faster. Although normal appearing, slight differences on cross sectional area of the cochlear nerve may affect performance. Measuring the size of the cochlear nerve on parasagittal magnetic resonance images may provide beneficial information on the postoperative rehabilitation process.
publishDate 2022
dc.date.none.fl_str_mv 2022-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942022000300390
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942022000300390
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.bjorl.2020.06.019
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.
publisher.none.fl_str_mv Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.
dc.source.none.fl_str_mv Brazilian Journal of Otorhinolaryngology v.88 n.3 2022
reponame:Brazilian Journal of Otorhinolaryngology
instname:Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)
instacron:ABORL-CCF
instname_str Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)
instacron_str ABORL-CCF
institution ABORL-CCF
reponame_str Brazilian Journal of Otorhinolaryngology
collection Brazilian Journal of Otorhinolaryngology
repository.name.fl_str_mv Brazilian Journal of Otorhinolaryngology - Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial (ABORL-CCF)
repository.mail.fl_str_mv revista@aborlccf.org.br||revista@aborlccf.org.br
_version_ 1754575994968080384