Comparison of three hand dynamometers in relation to the accuracy and precision of the measurements

Detalhes bibliográficos
Autor(a) principal: Amaral,Josária F.
Data de Publicação: 2012
Outros Autores: Mancini,Marcelly, Novo Júnior,José M.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Physical Therapy
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552012000300007
Resumo: BACKGROUND: Given the variety of available hand-held dynamometers and their different handle shapes, reliability studies are needed. Objectives: To compare the accuracy and reliability between three different hand-held dynamometers and analyze the influence of their handles on grip strength. Methods: The tests were performed with the Jamar® dynamometer, the Takei® dynamometer and the EMG System Manual Transducer with modified handle. Eighteen healthy volunteers aged 20.0±1.3 years without history of musculoskeletal disorders or trauma in the evaluated limbs were included. Data normality was tested using the Shapiro-Wilk test. To verify possible differences between the dynamometers, repeated measures ANOVA was administered, followed by Tukey post-hoc tests. Reliability between measurements was evaluated using intraclass correlation coefficient (ICC) and agreement was tested using Bland and Altman plots. The dynamometers calibration process was evaluated using linear regressions. RESULTS: We observed statistically significant differences on the female group between the Jamar® and the Takei® dynamometers (females p<0.001 and males p=0.022) and the EMG System Manual Transducer (female p<0.001 and males p=0.007). However, the Takei® dymamometer and the EMG System Manual Transducer were similar for both female (p=0.161) and male groups (p=0.850). Although acceptable values of intraclass correlation coefficients between measurements were identified, low agreement between the Jamar® dynamometer and all other instruments was found. CONCLUSIONS: The results demonstrated that there is an influence of the dynamometer's handle shapes on the measurements of grip strength. Furthermore, the results demonstrated the need for previous calibration of this type of instrument.
id ABRA-FT-1_78570b4fef3e8239cd4f9f532f2813ae
oai_identifier_str oai:scielo:S1413-35552012000300007
network_acronym_str ABRA-FT-1
network_name_str Brazilian Journal of Physical Therapy
repository_id_str
spelling Comparison of three hand dynamometers in relation to the accuracy and precision of the measurementsdynamometergrip strengthphysical therapyBACKGROUND: Given the variety of available hand-held dynamometers and their different handle shapes, reliability studies are needed. Objectives: To compare the accuracy and reliability between three different hand-held dynamometers and analyze the influence of their handles on grip strength. Methods: The tests were performed with the Jamar® dynamometer, the Takei® dynamometer and the EMG System Manual Transducer with modified handle. Eighteen healthy volunteers aged 20.0±1.3 years without history of musculoskeletal disorders or trauma in the evaluated limbs were included. Data normality was tested using the Shapiro-Wilk test. To verify possible differences between the dynamometers, repeated measures ANOVA was administered, followed by Tukey post-hoc tests. Reliability between measurements was evaluated using intraclass correlation coefficient (ICC) and agreement was tested using Bland and Altman plots. The dynamometers calibration process was evaluated using linear regressions. RESULTS: We observed statistically significant differences on the female group between the Jamar® and the Takei® dynamometers (females p<0.001 and males p=0.022) and the EMG System Manual Transducer (female p<0.001 and males p=0.007). However, the Takei® dymamometer and the EMG System Manual Transducer were similar for both female (p=0.161) and male groups (p=0.850). Although acceptable values of intraclass correlation coefficients between measurements were identified, low agreement between the Jamar® dynamometer and all other instruments was found. CONCLUSIONS: The results demonstrated that there is an influence of the dynamometer's handle shapes on the measurements of grip strength. Furthermore, the results demonstrated the need for previous calibration of this type of instrument.Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia 2012-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552012000300007Brazilian Journal of Physical Therapy v.16 n.3 2012reponame:Brazilian Journal of Physical Therapyinstname:Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)instacron:ABRAPG-FT10.1590/S1413-35552012000300007info:eu-repo/semantics/openAccessAmaral,Josária F.Mancini,MarcellyNovo Júnior,José M.eng2012-07-11T00:00:00Zoai:scielo:S1413-35552012000300007Revistahttps://www.scielo.br/j/rbfis/https://old.scielo.br/oai/scielo-oai.phpcontato@rbf-bjpt.org.br||contato@rbf-bjpt.org.br1809-92461413-3555opendoar:2012-07-11T00:00Brazilian Journal of Physical Therapy - Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)false
dc.title.none.fl_str_mv Comparison of three hand dynamometers in relation to the accuracy and precision of the measurements
title Comparison of three hand dynamometers in relation to the accuracy and precision of the measurements
spellingShingle Comparison of three hand dynamometers in relation to the accuracy and precision of the measurements
Amaral,Josária F.
dynamometer
grip strength
physical therapy
title_short Comparison of three hand dynamometers in relation to the accuracy and precision of the measurements
title_full Comparison of three hand dynamometers in relation to the accuracy and precision of the measurements
title_fullStr Comparison of three hand dynamometers in relation to the accuracy and precision of the measurements
title_full_unstemmed Comparison of three hand dynamometers in relation to the accuracy and precision of the measurements
title_sort Comparison of three hand dynamometers in relation to the accuracy and precision of the measurements
author Amaral,Josária F.
author_facet Amaral,Josária F.
Mancini,Marcelly
Novo Júnior,José M.
author_role author
author2 Mancini,Marcelly
Novo Júnior,José M.
author2_role author
author
dc.contributor.author.fl_str_mv Amaral,Josária F.
Mancini,Marcelly
Novo Júnior,José M.
dc.subject.por.fl_str_mv dynamometer
grip strength
physical therapy
topic dynamometer
grip strength
physical therapy
description BACKGROUND: Given the variety of available hand-held dynamometers and their different handle shapes, reliability studies are needed. Objectives: To compare the accuracy and reliability between three different hand-held dynamometers and analyze the influence of their handles on grip strength. Methods: The tests were performed with the Jamar® dynamometer, the Takei® dynamometer and the EMG System Manual Transducer with modified handle. Eighteen healthy volunteers aged 20.0±1.3 years without history of musculoskeletal disorders or trauma in the evaluated limbs were included. Data normality was tested using the Shapiro-Wilk test. To verify possible differences between the dynamometers, repeated measures ANOVA was administered, followed by Tukey post-hoc tests. Reliability between measurements was evaluated using intraclass correlation coefficient (ICC) and agreement was tested using Bland and Altman plots. The dynamometers calibration process was evaluated using linear regressions. RESULTS: We observed statistically significant differences on the female group between the Jamar® and the Takei® dynamometers (females p<0.001 and males p=0.022) and the EMG System Manual Transducer (female p<0.001 and males p=0.007). However, the Takei® dymamometer and the EMG System Manual Transducer were similar for both female (p=0.161) and male groups (p=0.850). Although acceptable values of intraclass correlation coefficients between measurements were identified, low agreement between the Jamar® dynamometer and all other instruments was found. CONCLUSIONS: The results demonstrated that there is an influence of the dynamometer's handle shapes on the measurements of grip strength. Furthermore, the results demonstrated the need for previous calibration of this type of instrument.
publishDate 2012
dc.date.none.fl_str_mv 2012-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552012000300007
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552012000300007
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1413-35552012000300007
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia
publisher.none.fl_str_mv Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia
dc.source.none.fl_str_mv Brazilian Journal of Physical Therapy v.16 n.3 2012
reponame:Brazilian Journal of Physical Therapy
instname:Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)
instacron:ABRAPG-FT
instname_str Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)
instacron_str ABRAPG-FT
institution ABRAPG-FT
reponame_str Brazilian Journal of Physical Therapy
collection Brazilian Journal of Physical Therapy
repository.name.fl_str_mv Brazilian Journal of Physical Therapy - Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)
repository.mail.fl_str_mv contato@rbf-bjpt.org.br||contato@rbf-bjpt.org.br
_version_ 1754575948826542080