Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study

Detalhes bibliográficos
Autor(a) principal: Rahnama,Leila
Data de Publicação: 2015
Outros Autores: Rezasoltani,Asghar, Khalkhali-Zavieh,Minoo, Rahnama,Behnam, Noori-Kochi,Farhang
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Physical Therapy
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552015000400279
Resumo: OBJECTIVES: This study was conducted with the purpose of evaluating the inter-session reliability of new software to measure the diameters of the cervical multifidus muscle (CMM), both at rest and during isometric contractions of the shoulder abductors in subjects with neck pain and in healthy individuals.METHOD: In the present study, the reliability of measuring the diameters of the CMM with the Sonosynch software was evaluated by using 24 participants, including 12 subjects with chronic neck pain and 12 healthy individuals. The anterior-posterior diameter (APD) and the lateral diameter (LD) of the CMM were measured in a resting state and then repeated during isometric contraction of the shoulder abductors. Measurements were taken on separate occasions 3 to 7 days apart in order to determine inter-session reliability. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and smallest detectable difference (SDD) were used to evaluate the relative and absolute reliability, respectively.RESULTS: The Sonosynch software has shown to be highly reliable in measuring the diameters of the CMM both in healthy subjects and in those with neck pain. The ICCs 95% CI for APD ranged from 0.84 to 0.94 in subjects with neck pain and from 0.86 to 0.94 in healthy subjects. For LD, the ICC 95% CI ranged from 0.64 to 0.95 in subjects with neck pain and from 0.82 to 0.92 in healthy subjects.CONCLUSIONS: Ultrasonographic measurement of the diameters of the CMM using Sonosynch has proved to be reliable especially for APD in healthy subjects as well as subjects with neck pain.
id ABRA-FT-1_99abaafd8366ee18da6b14b6c1b2bc83
oai_identifier_str oai:scielo:S1413-35552015000400279
network_acronym_str ABRA-FT-1
network_name_str Brazilian Journal of Physical Therapy
repository_id_str
spelling Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic studysoftwarecervical multifidus muscleneck painultrasonographyreliabilityOBJECTIVES: This study was conducted with the purpose of evaluating the inter-session reliability of new software to measure the diameters of the cervical multifidus muscle (CMM), both at rest and during isometric contractions of the shoulder abductors in subjects with neck pain and in healthy individuals.METHOD: In the present study, the reliability of measuring the diameters of the CMM with the Sonosynch software was evaluated by using 24 participants, including 12 subjects with chronic neck pain and 12 healthy individuals. The anterior-posterior diameter (APD) and the lateral diameter (LD) of the CMM were measured in a resting state and then repeated during isometric contraction of the shoulder abductors. Measurements were taken on separate occasions 3 to 7 days apart in order to determine inter-session reliability. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and smallest detectable difference (SDD) were used to evaluate the relative and absolute reliability, respectively.RESULTS: The Sonosynch software has shown to be highly reliable in measuring the diameters of the CMM both in healthy subjects and in those with neck pain. The ICCs 95% CI for APD ranged from 0.84 to 0.94 in subjects with neck pain and from 0.86 to 0.94 in healthy subjects. For LD, the ICC 95% CI ranged from 0.64 to 0.95 in subjects with neck pain and from 0.82 to 0.92 in healthy subjects.CONCLUSIONS: Ultrasonographic measurement of the diameters of the CMM using Sonosynch has proved to be reliable especially for APD in healthy subjects as well as subjects with neck pain.Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia 2015-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552015000400279Brazilian Journal of Physical Therapy v.19 n.4 2015reponame:Brazilian Journal of Physical Therapyinstname:Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)instacron:ABRAPG-FT10.1590/bjpt-rbf.2014.0097info:eu-repo/semantics/openAccessRahnama,LeilaRezasoltani,AsgharKhalkhali-Zavieh,MinooRahnama,BehnamNoori-Kochi,Farhangeng2015-09-30T00:00:00Zoai:scielo:S1413-35552015000400279Revistahttps://www.scielo.br/j/rbfis/https://old.scielo.br/oai/scielo-oai.phpcontato@rbf-bjpt.org.br||contato@rbf-bjpt.org.br1809-92461413-3555opendoar:2015-09-30T00:00Brazilian Journal of Physical Therapy - Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)false
dc.title.none.fl_str_mv Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study
title Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study
spellingShingle Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study
Rahnama,Leila
software
cervical multifidus muscle
neck pain
ultrasonography
reliability
title_short Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study
title_full Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study
title_fullStr Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study
title_full_unstemmed Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study
title_sort Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study
author Rahnama,Leila
author_facet Rahnama,Leila
Rezasoltani,Asghar
Khalkhali-Zavieh,Minoo
Rahnama,Behnam
Noori-Kochi,Farhang
author_role author
author2 Rezasoltani,Asghar
Khalkhali-Zavieh,Minoo
Rahnama,Behnam
Noori-Kochi,Farhang
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Rahnama,Leila
Rezasoltani,Asghar
Khalkhali-Zavieh,Minoo
Rahnama,Behnam
Noori-Kochi,Farhang
dc.subject.por.fl_str_mv software
cervical multifidus muscle
neck pain
ultrasonography
reliability
topic software
cervical multifidus muscle
neck pain
ultrasonography
reliability
description OBJECTIVES: This study was conducted with the purpose of evaluating the inter-session reliability of new software to measure the diameters of the cervical multifidus muscle (CMM), both at rest and during isometric contractions of the shoulder abductors in subjects with neck pain and in healthy individuals.METHOD: In the present study, the reliability of measuring the diameters of the CMM with the Sonosynch software was evaluated by using 24 participants, including 12 subjects with chronic neck pain and 12 healthy individuals. The anterior-posterior diameter (APD) and the lateral diameter (LD) of the CMM were measured in a resting state and then repeated during isometric contraction of the shoulder abductors. Measurements were taken on separate occasions 3 to 7 days apart in order to determine inter-session reliability. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and smallest detectable difference (SDD) were used to evaluate the relative and absolute reliability, respectively.RESULTS: The Sonosynch software has shown to be highly reliable in measuring the diameters of the CMM both in healthy subjects and in those with neck pain. The ICCs 95% CI for APD ranged from 0.84 to 0.94 in subjects with neck pain and from 0.86 to 0.94 in healthy subjects. For LD, the ICC 95% CI ranged from 0.64 to 0.95 in subjects with neck pain and from 0.82 to 0.92 in healthy subjects.CONCLUSIONS: Ultrasonographic measurement of the diameters of the CMM using Sonosynch has proved to be reliable especially for APD in healthy subjects as well as subjects with neck pain.
publishDate 2015
dc.date.none.fl_str_mv 2015-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552015000400279
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552015000400279
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/bjpt-rbf.2014.0097
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia
publisher.none.fl_str_mv Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia
dc.source.none.fl_str_mv Brazilian Journal of Physical Therapy v.19 n.4 2015
reponame:Brazilian Journal of Physical Therapy
instname:Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)
instacron:ABRAPG-FT
instname_str Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)
instacron_str ABRAPG-FT
institution ABRAPG-FT
reponame_str Brazilian Journal of Physical Therapy
collection Brazilian Journal of Physical Therapy
repository.name.fl_str_mv Brazilian Journal of Physical Therapy - Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)
repository.mail.fl_str_mv contato@rbf-bjpt.org.br||contato@rbf-bjpt.org.br
_version_ 1754575950399406080