Reliability of measuring pectoralis minor muscle resting length in subjects with and without signs of shoulder impingement

Detalhes bibliográficos
Autor(a) principal: Rosa,Dayana P.
Data de Publicação: 2016
Outros Autores: Borstad,John D., Pires,Elisa D., Camargo,Paula R.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Physical Therapy
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552016000200176
Resumo: Background: Pectoralis minor adaptive shortening may change scapula resting position and scapular kinematics during arm elevation. A reliable and clinically feasible method for measuring pectoralis minor length will be useful for clinical decision making when evaluating and treating individuals with shoulder pain and dysfunction. Objectives: To evaluate intrarater, interrater, and between-day reliability of a pectoralis minor (PM) muscle length measurement in subjects with and without signs of shoulder impingement. Method: A convenience sample of 100 individuals (50 asymptomatic and 50 symptomatic) participated in this study. Intra- and interrater reliability of the measurement was estimated in 50 individuals (25 asymptomatic and 25 symptomatic), and between-day reliability of the measurement repeated over an interval of 7 days was estimated in an independent sample of 50 additional participants. Pectoralis minor length was measured using a flexible tape measure with subjects standing. Results: Intraclass correlation coefficients (ICC3,k) for intrarater and interrater reliability ranged from 0.86-0.97 and 0.95 for between-day reliability in both groups. Standard error of measurements (SEM) ranged from 0.30-0.42 cm, 0.70-0.84 cm, and 0.40-0.41 cm for intrarater, interrater, and between-day reliability, respectively, across the sample. The minimal detectable change (MDC) for between-day measurements ranged from 1.13-1.14 cm for both groups. Conclusions: In asymptomatic individuals and in those with signs of shoulder impingement, a single rater or pair of raters can measure pectoralis minor muscle length using a tape measure with very good reliability. This measurement can also be reliably used by the same rater over a seven day interval.
id ABRA-FT-1_f336b57e39306f2f70c6b91149d1b7d5
oai_identifier_str oai:scielo:S1413-35552016000200176
network_acronym_str ABRA-FT-1
network_name_str Brazilian Journal of Physical Therapy
repository_id_str
spelling Reliability of measuring pectoralis minor muscle resting length in subjects with and without signs of shoulder impingementmeasurementscapulaphysical therapytightness Background: Pectoralis minor adaptive shortening may change scapula resting position and scapular kinematics during arm elevation. A reliable and clinically feasible method for measuring pectoralis minor length will be useful for clinical decision making when evaluating and treating individuals with shoulder pain and dysfunction. Objectives: To evaluate intrarater, interrater, and between-day reliability of a pectoralis minor (PM) muscle length measurement in subjects with and without signs of shoulder impingement. Method: A convenience sample of 100 individuals (50 asymptomatic and 50 symptomatic) participated in this study. Intra- and interrater reliability of the measurement was estimated in 50 individuals (25 asymptomatic and 25 symptomatic), and between-day reliability of the measurement repeated over an interval of 7 days was estimated in an independent sample of 50 additional participants. Pectoralis minor length was measured using a flexible tape measure with subjects standing. Results: Intraclass correlation coefficients (ICC3,k) for intrarater and interrater reliability ranged from 0.86-0.97 and 0.95 for between-day reliability in both groups. Standard error of measurements (SEM) ranged from 0.30-0.42 cm, 0.70-0.84 cm, and 0.40-0.41 cm for intrarater, interrater, and between-day reliability, respectively, across the sample. The minimal detectable change (MDC) for between-day measurements ranged from 1.13-1.14 cm for both groups. Conclusions: In asymptomatic individuals and in those with signs of shoulder impingement, a single rater or pair of raters can measure pectoralis minor muscle length using a tape measure with very good reliability. This measurement can also be reliably used by the same rater over a seven day interval.Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia 2016-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552016000200176Brazilian Journal of Physical Therapy v.20 n.2 2016reponame:Brazilian Journal of Physical Therapyinstname:Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)instacron:ABRAPG-FT10.1590/bjpt-rbf.2014.0146info:eu-repo/semantics/openAccessRosa,Dayana P.Borstad,John D.Pires,Elisa D.Camargo,Paula R.eng2016-07-15T00:00:00Zoai:scielo:S1413-35552016000200176Revistahttps://www.scielo.br/j/rbfis/https://old.scielo.br/oai/scielo-oai.phpcontato@rbf-bjpt.org.br||contato@rbf-bjpt.org.br1809-92461413-3555opendoar:2016-07-15T00:00Brazilian Journal of Physical Therapy - Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)false
dc.title.none.fl_str_mv Reliability of measuring pectoralis minor muscle resting length in subjects with and without signs of shoulder impingement
title Reliability of measuring pectoralis minor muscle resting length in subjects with and without signs of shoulder impingement
spellingShingle Reliability of measuring pectoralis minor muscle resting length in subjects with and without signs of shoulder impingement
Rosa,Dayana P.
measurement
scapula
physical therapy
tightness
title_short Reliability of measuring pectoralis minor muscle resting length in subjects with and without signs of shoulder impingement
title_full Reliability of measuring pectoralis minor muscle resting length in subjects with and without signs of shoulder impingement
title_fullStr Reliability of measuring pectoralis minor muscle resting length in subjects with and without signs of shoulder impingement
title_full_unstemmed Reliability of measuring pectoralis minor muscle resting length in subjects with and without signs of shoulder impingement
title_sort Reliability of measuring pectoralis minor muscle resting length in subjects with and without signs of shoulder impingement
author Rosa,Dayana P.
author_facet Rosa,Dayana P.
Borstad,John D.
Pires,Elisa D.
Camargo,Paula R.
author_role author
author2 Borstad,John D.
Pires,Elisa D.
Camargo,Paula R.
author2_role author
author
author
dc.contributor.author.fl_str_mv Rosa,Dayana P.
Borstad,John D.
Pires,Elisa D.
Camargo,Paula R.
dc.subject.por.fl_str_mv measurement
scapula
physical therapy
tightness
topic measurement
scapula
physical therapy
tightness
description Background: Pectoralis minor adaptive shortening may change scapula resting position and scapular kinematics during arm elevation. A reliable and clinically feasible method for measuring pectoralis minor length will be useful for clinical decision making when evaluating and treating individuals with shoulder pain and dysfunction. Objectives: To evaluate intrarater, interrater, and between-day reliability of a pectoralis minor (PM) muscle length measurement in subjects with and without signs of shoulder impingement. Method: A convenience sample of 100 individuals (50 asymptomatic and 50 symptomatic) participated in this study. Intra- and interrater reliability of the measurement was estimated in 50 individuals (25 asymptomatic and 25 symptomatic), and between-day reliability of the measurement repeated over an interval of 7 days was estimated in an independent sample of 50 additional participants. Pectoralis minor length was measured using a flexible tape measure with subjects standing. Results: Intraclass correlation coefficients (ICC3,k) for intrarater and interrater reliability ranged from 0.86-0.97 and 0.95 for between-day reliability in both groups. Standard error of measurements (SEM) ranged from 0.30-0.42 cm, 0.70-0.84 cm, and 0.40-0.41 cm for intrarater, interrater, and between-day reliability, respectively, across the sample. The minimal detectable change (MDC) for between-day measurements ranged from 1.13-1.14 cm for both groups. Conclusions: In asymptomatic individuals and in those with signs of shoulder impingement, a single rater or pair of raters can measure pectoralis minor muscle length using a tape measure with very good reliability. This measurement can also be reliably used by the same rater over a seven day interval.
publishDate 2016
dc.date.none.fl_str_mv 2016-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552016000200176
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552016000200176
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/bjpt-rbf.2014.0146
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia
publisher.none.fl_str_mv Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia
dc.source.none.fl_str_mv Brazilian Journal of Physical Therapy v.20 n.2 2016
reponame:Brazilian Journal of Physical Therapy
instname:Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)
instacron:ABRAPG-FT
instname_str Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)
instacron_str ABRAPG-FT
institution ABRAPG-FT
reponame_str Brazilian Journal of Physical Therapy
collection Brazilian Journal of Physical Therapy
repository.name.fl_str_mv Brazilian Journal of Physical Therapy - Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)
repository.mail.fl_str_mv contato@rbf-bjpt.org.br||contato@rbf-bjpt.org.br
_version_ 1754575950741241856