Resumo: ABSTRACT Hydrometric measurements undertaken in channels with high velocities are conditioned to the particularities of the flow, which is often characterized by instantaneous fluctuations and disturbances on the free surface. In such cases, the uncertainties associated with velocity fluctuations exceed the precision offered by the instruments that are employed in conventional techniques. A reasonable accuracy of the results is therefore sufficient to accomplish the objective of the measurements. The use of devices based on Pitot’s principle in fast open-channel flows could be an effective alternative to conventional velocity meters. This study aimed to develop a Pitot tube in its simplest configuration and evaluate its performance in a laboratory channel at velocities ranging from 0.2 to 2.0 m/s. The uncertainties in the static and total head readings were propagated to the output velocities, showing that the device built has the potential for measurements over 1.2 m/s, but it is not recommended for low velocities (<0.6 m/s). The results were compared to those taken using an Acoustic Doppler Velocimeter (ADV). The instantaneous velocity readings indicated uncertainties of the same order of magnitude in both instruments. The differences between the mean velocities measured by the Pitot tube and the ADV were restricted to an agreement range of 15%, which is expected to be gradually reduced with further increase in flow velocity. The results showed the similar performances of both devices regarding the higher velocity estimates. Therefore, velocity meters should be developed to employ Pitot devices as an alternative method in high-velocity open-channel flows.
id ABRH-1_e82b270898a3eede4390b0cb885022fa
oai_identifier_str oai:scielo:S2318-03312017000100402
network_acronym_str ABRH-1
network_name_str RBRH (Online)
repository_id_str
spelling An alternative method for measuring velocities in open-channel flows: perfomance evaluation of a Pitot tube compared to an acoustic meterHydrometryOpen channel flowDifferential head metersPitot tubeABSTRACT Hydrometric measurements undertaken in channels with high velocities are conditioned to the particularities of the flow, which is often characterized by instantaneous fluctuations and disturbances on the free surface. In such cases, the uncertainties associated with velocity fluctuations exceed the precision offered by the instruments that are employed in conventional techniques. A reasonable accuracy of the results is therefore sufficient to accomplish the objective of the measurements. The use of devices based on Pitot’s principle in fast open-channel flows could be an effective alternative to conventional velocity meters. This study aimed to develop a Pitot tube in its simplest configuration and evaluate its performance in a laboratory channel at velocities ranging from 0.2 to 2.0 m/s. The uncertainties in the static and total head readings were propagated to the output velocities, showing that the device built has the potential for measurements over 1.2 m/s, but it is not recommended for low velocities (<0.6 m/s). The results were compared to those taken using an Acoustic Doppler Velocimeter (ADV). The instantaneous velocity readings indicated uncertainties of the same order of magnitude in both instruments. The differences between the mean velocities measured by the Pitot tube and the ADV were restricted to an agreement range of 15%, which is expected to be gradually reduced with further increase in flow velocity. The results showed the similar performances of both devices regarding the higher velocity estimates. Therefore, velocity meters should be developed to employ Pitot devices as an alternative method in high-velocity open-channel flows.Associação Brasileira de Recursos Hídricos2017-01-01info:eu-repo/semantics/reportinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2318-03312017000100402RBRH v.22 2017reponame:RBRH (Online)instname:Associação Brasileira de Recursos Hídricos (ABRH)instacron:ABRH10.1590/2318-0331.011716099info:eu-repo/semantics/openAccessAlmeida,Arlan ScortegagnaSouza,Vladimir Caramori Borges deeng2017-12-08T00:00:00Zoai:scielo:S2318-03312017000100402Revistahttps://www.scielo.br/j/rbrh/https://old.scielo.br/oai/scielo-oai.php||rbrh@abrh.org.br2318-03311414-381Xopendoar:2017-12-08T00:00RBRH (Online) - Associação Brasileira de Recursos Hídricos (ABRH)false
dc.title.none.fl_str_mv An alternative method for measuring velocities in open-channel flows: perfomance evaluation of a Pitot tube compared to an acoustic meter
title An alternative method for measuring velocities in open-channel flows: perfomance evaluation of a Pitot tube compared to an acoustic meter
spellingShingle An alternative method for measuring velocities in open-channel flows: perfomance evaluation of a Pitot tube compared to an acoustic meter
Almeida,Arlan Scortegagna
Hydrometry
Open channel flow
Differential head meters
Pitot tube
title_short An alternative method for measuring velocities in open-channel flows: perfomance evaluation of a Pitot tube compared to an acoustic meter
title_full An alternative method for measuring velocities in open-channel flows: perfomance evaluation of a Pitot tube compared to an acoustic meter
title_fullStr An alternative method for measuring velocities in open-channel flows: perfomance evaluation of a Pitot tube compared to an acoustic meter
title_full_unstemmed An alternative method for measuring velocities in open-channel flows: perfomance evaluation of a Pitot tube compared to an acoustic meter
title_sort An alternative method for measuring velocities in open-channel flows: perfomance evaluation of a Pitot tube compared to an acoustic meter
author Almeida,Arlan Scortegagna
author_facet Almeida,Arlan Scortegagna
Souza,Vladimir Caramori Borges de
author_role author
author2 Souza,Vladimir Caramori Borges de
author2_role author
dc.contributor.author.fl_str_mv Almeida,Arlan Scortegagna
Souza,Vladimir Caramori Borges de
dc.subject.por.fl_str_mv Hydrometry
Open channel flow
Differential head meters
Pitot tube
topic Hydrometry
Open channel flow
Differential head meters
Pitot tube
description ABSTRACT Hydrometric measurements undertaken in channels with high velocities are conditioned to the particularities of the flow, which is often characterized by instantaneous fluctuations and disturbances on the free surface. In such cases, the uncertainties associated with velocity fluctuations exceed the precision offered by the instruments that are employed in conventional techniques. A reasonable accuracy of the results is therefore sufficient to accomplish the objective of the measurements. The use of devices based on Pitot’s principle in fast open-channel flows could be an effective alternative to conventional velocity meters. This study aimed to develop a Pitot tube in its simplest configuration and evaluate its performance in a laboratory channel at velocities ranging from 0.2 to 2.0 m/s. The uncertainties in the static and total head readings were propagated to the output velocities, showing that the device built has the potential for measurements over 1.2 m/s, but it is not recommended for low velocities (<0.6 m/s). The results were compared to those taken using an Acoustic Doppler Velocimeter (ADV). The instantaneous velocity readings indicated uncertainties of the same order of magnitude in both instruments. The differences between the mean velocities measured by the Pitot tube and the ADV were restricted to an agreement range of 15%, which is expected to be gradually reduced with further increase in flow velocity. The results showed the similar performances of both devices regarding the higher velocity estimates. Therefore, velocity meters should be developed to employ Pitot devices as an alternative method in high-velocity open-channel flows.
publishDate 2017
dc.date.none.fl_str_mv 2017-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/report
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format report
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2318-03312017000100402
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2318-03312017000100402
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/2318-0331.011716099
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Recursos Hídricos
publisher.none.fl_str_mv Associação Brasileira de Recursos Hídricos
dc.source.none.fl_str_mv RBRH v.22 2017
reponame:RBRH (Online)
instname:Associação Brasileira de Recursos Hídricos (ABRH)
instacron:ABRH
instname_str Associação Brasileira de Recursos Hídricos (ABRH)
instacron_str ABRH
institution ABRH
reponame_str RBRH (Online)
collection RBRH (Online)
repository.name.fl_str_mv RBRH (Online) - Associação Brasileira de Recursos Hídricos (ABRH)
repository.mail.fl_str_mv ||rbrh@abrh.org.br
_version_ 1754734701498597376