Assessment of the Use of Negative Polarity in Double-Wire MIG/MAG-Welding Filling Passes

Detalhes bibliográficos
Autor(a) principal: Mishchenko,Andrii
Data de Publicação: 2015
Outros Autores: Caimacan,Dumitru, Scotti,Américo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista soldagem & inspeção (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-92242015000100048
Resumo: The aim of this work was to evaluate the use of negative polarity in the trail wire in double-wire MIG/MAG-welding filling passes. A comparative study of the conventional technique (two wires working with pulsed DCEP) and the proposed combinations of pulsed DCEP in the lead wire with pulsed DCEN in the trail wire and pulsed DCEP in the lead wire with controlled short-circuit CSC(-) in the trail wire was carried out. The mean current in each wire and the ratio of travel speed to wire feed rate (for the same bead volume per unit weld length), as well as wire type and size, shielding gas composition and joint type (a butt joint in a flat position), were kept constant. Bead surface finish and geometry, deposition efficiency and maximum travel speed for each combination were evaluated. In conclusion, the use of negative polarity in the trail wire increased the deposition rate (higher travel speeds for the same bead) compared with the use of pulsed DCEP in both wires but at the cost of reduced operational robustness, as the conventional technique allowed a sound bead to be produced over a wider range of travel speeds. In addition, beads welded using negative polarity had smaller fusion zones and narrower heat-affected zones but higher convexities.
id ABS-1_cfd959bebfba2e15f55651a0b1f6f8b9
oai_identifier_str oai:scielo:S0104-92242015000100048
network_acronym_str ABS-1
network_name_str Revista soldagem & inspeção (Online)
repository_id_str
spelling Assessment of the Use of Negative Polarity in Double-Wire MIG/MAG-Welding Filling PassesDouble Wire MIG/MAG WeldingNegative PolarityFilling PassThe aim of this work was to evaluate the use of negative polarity in the trail wire in double-wire MIG/MAG-welding filling passes. A comparative study of the conventional technique (two wires working with pulsed DCEP) and the proposed combinations of pulsed DCEP in the lead wire with pulsed DCEN in the trail wire and pulsed DCEP in the lead wire with controlled short-circuit CSC(-) in the trail wire was carried out. The mean current in each wire and the ratio of travel speed to wire feed rate (for the same bead volume per unit weld length), as well as wire type and size, shielding gas composition and joint type (a butt joint in a flat position), were kept constant. Bead surface finish and geometry, deposition efficiency and maximum travel speed for each combination were evaluated. In conclusion, the use of negative polarity in the trail wire increased the deposition rate (higher travel speeds for the same bead) compared with the use of pulsed DCEP in both wires but at the cost of reduced operational robustness, as the conventional technique allowed a sound bead to be produced over a wider range of travel speeds. In addition, beads welded using negative polarity had smaller fusion zones and narrower heat-affected zones but higher convexities.Associação Brasileira de Soldagem2015-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-92242015000100048Soldagem & Inspeção v.20 n.1 2015reponame:Revista soldagem & inspeção (Online)instname:Associação Brasileira de Soldagem (ABS)instacron:ABS10.1590/0104-9224/SI2001.06info:eu-repo/semantics/openAccessMishchenko,AndriiCaimacan,DumitruScotti,Américoeng2015-07-08T00:00:00Zoai:scielo:S0104-92242015000100048Revistahttp://abs-soldagem.org.br/s&i/https://old.scielo.br/oai/scielo-oai.php||revista-si@abs-soldagem.org.br0104-92241980-6973opendoar:2015-07-08T00:00Revista soldagem & inspeção (Online) - Associação Brasileira de Soldagem (ABS)false
dc.title.none.fl_str_mv Assessment of the Use of Negative Polarity in Double-Wire MIG/MAG-Welding Filling Passes
title Assessment of the Use of Negative Polarity in Double-Wire MIG/MAG-Welding Filling Passes
spellingShingle Assessment of the Use of Negative Polarity in Double-Wire MIG/MAG-Welding Filling Passes
Mishchenko,Andrii
Double Wire MIG/MAG Welding
Negative Polarity
Filling Pass
title_short Assessment of the Use of Negative Polarity in Double-Wire MIG/MAG-Welding Filling Passes
title_full Assessment of the Use of Negative Polarity in Double-Wire MIG/MAG-Welding Filling Passes
title_fullStr Assessment of the Use of Negative Polarity in Double-Wire MIG/MAG-Welding Filling Passes
title_full_unstemmed Assessment of the Use of Negative Polarity in Double-Wire MIG/MAG-Welding Filling Passes
title_sort Assessment of the Use of Negative Polarity in Double-Wire MIG/MAG-Welding Filling Passes
author Mishchenko,Andrii
author_facet Mishchenko,Andrii
Caimacan,Dumitru
Scotti,Américo
author_role author
author2 Caimacan,Dumitru
Scotti,Américo
author2_role author
author
dc.contributor.author.fl_str_mv Mishchenko,Andrii
Caimacan,Dumitru
Scotti,Américo
dc.subject.por.fl_str_mv Double Wire MIG/MAG Welding
Negative Polarity
Filling Pass
topic Double Wire MIG/MAG Welding
Negative Polarity
Filling Pass
description The aim of this work was to evaluate the use of negative polarity in the trail wire in double-wire MIG/MAG-welding filling passes. A comparative study of the conventional technique (two wires working with pulsed DCEP) and the proposed combinations of pulsed DCEP in the lead wire with pulsed DCEN in the trail wire and pulsed DCEP in the lead wire with controlled short-circuit CSC(-) in the trail wire was carried out. The mean current in each wire and the ratio of travel speed to wire feed rate (for the same bead volume per unit weld length), as well as wire type and size, shielding gas composition and joint type (a butt joint in a flat position), were kept constant. Bead surface finish and geometry, deposition efficiency and maximum travel speed for each combination were evaluated. In conclusion, the use of negative polarity in the trail wire increased the deposition rate (higher travel speeds for the same bead) compared with the use of pulsed DCEP in both wires but at the cost of reduced operational robustness, as the conventional technique allowed a sound bead to be produced over a wider range of travel speeds. In addition, beads welded using negative polarity had smaller fusion zones and narrower heat-affected zones but higher convexities.
publishDate 2015
dc.date.none.fl_str_mv 2015-03-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-92242015000100048
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-92242015000100048
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0104-9224/SI2001.06
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Brasileira de Soldagem
publisher.none.fl_str_mv Associação Brasileira de Soldagem
dc.source.none.fl_str_mv Soldagem & Inspeção v.20 n.1 2015
reponame:Revista soldagem & inspeção (Online)
instname:Associação Brasileira de Soldagem (ABS)
instacron:ABS
instname_str Associação Brasileira de Soldagem (ABS)
instacron_str ABS
institution ABS
reponame_str Revista soldagem & inspeção (Online)
collection Revista soldagem & inspeção (Online)
repository.name.fl_str_mv Revista soldagem & inspeção (Online) - Associação Brasileira de Soldagem (ABS)
repository.mail.fl_str_mv ||revista-si@abs-soldagem.org.br
_version_ 1754213003466637312