Effect of radiation on endothelial functions in workers exposed to radiation

Detalhes bibliográficos
Autor(a) principal: Mansiroglu,Asli Kurtar
Data de Publicação: 2020
Outros Autores: Isa,Sincer, Yilmaz,Gunes
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista da Associação Médica Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-42302020000700992
Resumo: SUMMARY OBJECTIVE Our aim is to determine whether radiation affects the endothelial function of hospital staff working in the radiation unit for diagnostic and therapeutic purposes. We have evaluated endothelial function with vascular imaging parameters such as flow-mediated dilatation (FMD) and aortic stiffness index (ASI). METHODS A total of 75 employees, 35 of whom are exposed to radiation due to their profession and 40 as the control group, were included in our single-centered study. Demographic data, FMD, aortic stiffness, and echocardiographic findings of the two groups were compared. RESULTS There were no significant differences in demographic data. Median FMD values tended to be lower in the radiation exposure group [7.89 (2.17-21.88) vs. 11.69 (5.13-27.27) p=0.09]. The FMD value was significantly lower in the catheter laboratory group than in the radiation-exposed (p=0.034) and control (p=0.012) groups. However, there was no statistically significant difference between the non-catheter lab radiation exposed group and the control group (p=0.804). In addition, there was no statistically significant difference in the ASI value between the groups (p=0.201). CONCLUSION We have found that FMD is decreased among hospital staff working in radiation-associated areas. This may be an early marker for radiation-induced endothelial dysfunction.
id AMB-1_e722bb3215bd8a83c545b9d253016355
oai_identifier_str oai:scielo:S0104-42302020000700992
network_acronym_str AMB-1
network_name_str Revista da Associação Médica Brasileira (Online)
repository_id_str
spelling Effect of radiation on endothelial functions in workers exposed to radiationAortic StiffnessFlow-Mediated DilatationRadiationEndothelium, vascularOccupational exposureRadiation exposureSUMMARY OBJECTIVE Our aim is to determine whether radiation affects the endothelial function of hospital staff working in the radiation unit for diagnostic and therapeutic purposes. We have evaluated endothelial function with vascular imaging parameters such as flow-mediated dilatation (FMD) and aortic stiffness index (ASI). METHODS A total of 75 employees, 35 of whom are exposed to radiation due to their profession and 40 as the control group, were included in our single-centered study. Demographic data, FMD, aortic stiffness, and echocardiographic findings of the two groups were compared. RESULTS There were no significant differences in demographic data. Median FMD values tended to be lower in the radiation exposure group [7.89 (2.17-21.88) vs. 11.69 (5.13-27.27) p=0.09]. The FMD value was significantly lower in the catheter laboratory group than in the radiation-exposed (p=0.034) and control (p=0.012) groups. However, there was no statistically significant difference between the non-catheter lab radiation exposed group and the control group (p=0.804). In addition, there was no statistically significant difference in the ASI value between the groups (p=0.201). CONCLUSION We have found that FMD is decreased among hospital staff working in radiation-associated areas. This may be an early marker for radiation-induced endothelial dysfunction.Associação Médica Brasileira2020-07-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-42302020000700992Revista da Associação Médica Brasileira v.66 n.7 2020reponame:Revista da Associação Médica Brasileira (Online)instname:Associação Médica Brasileira (AMB)instacron:AMB10.1590/1806-9282.66.7.992info:eu-repo/semantics/openAccessMansiroglu,Asli KurtarIsa,SincerYilmaz,Guneseng2020-08-19T00:00:00Zoai:scielo:S0104-42302020000700992Revistahttps://ramb.amb.org.br/ultimas-edicoes/#https://old.scielo.br/oai/scielo-oai.php||ramb@amb.org.br1806-92820104-4230opendoar:2020-08-19T00:00Revista da Associação Médica Brasileira (Online) - Associação Médica Brasileira (AMB)false
dc.title.none.fl_str_mv Effect of radiation on endothelial functions in workers exposed to radiation
title Effect of radiation on endothelial functions in workers exposed to radiation
spellingShingle Effect of radiation on endothelial functions in workers exposed to radiation
Mansiroglu,Asli Kurtar
Aortic Stiffness
Flow-Mediated Dilatation
Radiation
Endothelium, vascular
Occupational exposure
Radiation exposure
title_short Effect of radiation on endothelial functions in workers exposed to radiation
title_full Effect of radiation on endothelial functions in workers exposed to radiation
title_fullStr Effect of radiation on endothelial functions in workers exposed to radiation
title_full_unstemmed Effect of radiation on endothelial functions in workers exposed to radiation
title_sort Effect of radiation on endothelial functions in workers exposed to radiation
author Mansiroglu,Asli Kurtar
author_facet Mansiroglu,Asli Kurtar
Isa,Sincer
Yilmaz,Gunes
author_role author
author2 Isa,Sincer
Yilmaz,Gunes
author2_role author
author
dc.contributor.author.fl_str_mv Mansiroglu,Asli Kurtar
Isa,Sincer
Yilmaz,Gunes
dc.subject.por.fl_str_mv Aortic Stiffness
Flow-Mediated Dilatation
Radiation
Endothelium, vascular
Occupational exposure
Radiation exposure
topic Aortic Stiffness
Flow-Mediated Dilatation
Radiation
Endothelium, vascular
Occupational exposure
Radiation exposure
description SUMMARY OBJECTIVE Our aim is to determine whether radiation affects the endothelial function of hospital staff working in the radiation unit for diagnostic and therapeutic purposes. We have evaluated endothelial function with vascular imaging parameters such as flow-mediated dilatation (FMD) and aortic stiffness index (ASI). METHODS A total of 75 employees, 35 of whom are exposed to radiation due to their profession and 40 as the control group, were included in our single-centered study. Demographic data, FMD, aortic stiffness, and echocardiographic findings of the two groups were compared. RESULTS There were no significant differences in demographic data. Median FMD values tended to be lower in the radiation exposure group [7.89 (2.17-21.88) vs. 11.69 (5.13-27.27) p=0.09]. The FMD value was significantly lower in the catheter laboratory group than in the radiation-exposed (p=0.034) and control (p=0.012) groups. However, there was no statistically significant difference between the non-catheter lab radiation exposed group and the control group (p=0.804). In addition, there was no statistically significant difference in the ASI value between the groups (p=0.201). CONCLUSION We have found that FMD is decreased among hospital staff working in radiation-associated areas. This may be an early marker for radiation-induced endothelial dysfunction.
publishDate 2020
dc.date.none.fl_str_mv 2020-07-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-42302020000700992
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-42302020000700992
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1806-9282.66.7.992
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Médica Brasileira
publisher.none.fl_str_mv Associação Médica Brasileira
dc.source.none.fl_str_mv Revista da Associação Médica Brasileira v.66 n.7 2020
reponame:Revista da Associação Médica Brasileira (Online)
instname:Associação Médica Brasileira (AMB)
instacron:AMB
instname_str Associação Médica Brasileira (AMB)
instacron_str AMB
institution AMB
reponame_str Revista da Associação Médica Brasileira (Online)
collection Revista da Associação Médica Brasileira (Online)
repository.name.fl_str_mv Revista da Associação Médica Brasileira (Online) - Associação Médica Brasileira (AMB)
repository.mail.fl_str_mv ||ramb@amb.org.br
_version_ 1754212835186966528